Home > M12 Distribution Blocks > Active M12 Distribution Blocks >

Lumberg Automation 0980 ESL 399-121 4 Input / 4 Output / 8 IO-Link Master M12 Distribution Block, L-Coded Power


Lumberg Automation 8 Port I/O Master M12 Distribution Block
Lumberg Automation 0980 ESL 399-121 4 Input / 4 Output / 8 IO-Link Master M12 Distribution Block
 
Alternative Views:


Price: $484.28
Note: Please call or email [email protected] for alternatives
MFG P/N: 934879004
MFG: Lumberg Automation
Weight (lbs): 1.1

Quantity in Stock :(Out of Stock)


Availability:
Out of Stock
Product Code: 934879004
Qty:

  
Description
 

The Lumberg Automation 934879004 0980 ESL 399-121 Lion-P is an 8 port 5 pin M12 distribution block IO-Link Master, with 4 digital inputs, 4 digital outputs, and eight 5 pin M12 A-coded I/O connections. Also has two 4 pin M12 D-coded bus ports & two 5 pin M1 L coded power supply ports. LED indicators show port status.

Features

  • Provides multi-protocol support (Profinet & Ethernet/IP)
  • Transmit diagnostic data of IO-Link sensors and actuators
  • Made to stand up to demanding conditions
  • Useful for such applications as transportation, water treatment, robotics, packaging, and machine building
  • Reverse polarity protection

Lumberg Automation 0980 ESL 399-121 Manuals

Specifications

  • Dimensions- 200mm Length x 59.6mm Width x 30.7mm Height (7.87" x 2.35" x 1.2")
  • Device Type- I/O-Link Master
  • Protocol- Ethernet/IP, Profinet
  • I/O Function- 4 Digital Input / 4 Digital Output / 8 IO-Link
  • Bus Connection- 4 Pin D-coded M12 LAN
  • Power Supply Connection- 5 Pin L-Coded M12 Power
  • I/O Connection- 5 Pin A-Coded M12
  • Housing Material- Nickel Plated Die Cast Zinc
  • IP Rating- IP 65, IP 67, IP 69K
  • Potted- Yes
  • Operating Temperature- -20 C to 70 C (-4 F to 158 F)
  • Storage Temperature- -25 C to 85 C (-13 F to 185 F)
  • Humidity- 5 - 95%
  • Mean Time to Failure- 574 years
  • Contact Base Material- Gold Plated Copper Alloy
  • Contact Bearer Material- Polyamide
  • O-Ring- FKM
  • Approvals- CE, RoHS, cULus
Profinet
  • Number of Connections- 2
  • Specification- V2.3X
  • Conformance Class- C
  • Performance Class- RT (switch supports IRT)
  • Netload Class- II
  • Transmission Rate- Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method- 100BaseTX, with auto-negotiation & auto-crossing
  • Cycle Time / Update Rate- Min 1 ms
  • Addressing- DCP
  • Fast Startup- Supported, </= 2000 ms
  • Media Redundancy Protocol- Supported, MRP client
  • Shared Device- Supported
  • Topology Detection- LLDP, SNMP V1
  • Easy Device Replacement- Supported, based on LLDP
  • Supported Network Protocols- ARP, HTTP, Ping, SNMP V1, TCP/IP
Ethernet/IP
  • Number of Connections- 2
  • Specification- CIP V3.1x, EIP Adaption of CIP V1.1x
  • Transmission Rate- Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method- 100BaseTX, with auto-negotiation & auto-crossing
  • Cycle Time / Update Rate- Min 1 ms
  • Addressing- BootP, DHCP, Rotary Address Switches
  • Address Switches Range- 0 to 255 dec
  • Connection Types- Exclusive Owner, Input Only, Listen Only
  • CIP Msg Connection Limit- 6
  • CIP I/O Connection Limit- 3
  • Device Level Ring- Supported, Beacon based
  • Quick Connect- Not Supported
  • Supported Network Protocols- ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP
Power Supply
Connection Module Supply

  • Number of Connections- 2
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
  • Current Consumption- 180 mA @ 24V DC
Connection Sensor Supply
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
Connection Actuator Supply (via Module Supply Connection)
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
IO-Link Master Channels
  • Number of Channels- Up to 8, configurable
  • IO-Link Class A Ports- 4 (1-4)
  • IO-Link Class B Ports- 4 (5-8)
  • IO-Link Specification- V1.1.2
  • Parameter Storage- Supported
  • Supported COM Modes- 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3)
  • Cycle Time/Update Rate- min. 8 ms for all channels at 32 Byte IN / OUT
  • Nominal Voltage- 24 V DC via US (system power supply)
  • Nominal Current C/Q (Pin 4)- max. 500 mA (via US)
  • Nominal Current 1L+ (Pin 1)- max. 500 mA (via US)
  • Nominal Current 2L+/Uaux (Pin 2, B Ports)- max. 2 A per port (via Uaux)
  • Perm. Conductor Length to Device- </= 20 M
Digital Input Channels
  • Number of Channels- Up to 12, configurable
  • Number of Ports- 8
  • Channel Type- Type 1 according to IEC 61131-2
  • Input Wiring- 2, 3 wire
  • Nominal Voltage- 24V DC
  • Nominal Current- 3 mA
  • Sensor Current Supply- Max. 500 mA per port via 1L+
  • Sensor Type- PNP
  • Input Voltage Range- -0.3V DC to 5 V DC (0 signal), 15V DC to 30V DC (1 signal)
  • Protective Circuit- Electronically: Overload Protection, Short-circuit Protection
Digital Output Channels
  • Number of Channels- Up to 12, configurable
  • Number of Ports- 8
  • Channel Type- P-Switching
  • Output Wiring- 2 wire
  • Nominal Voltage-24V DC via system power supply (Pin 4) / 24V DC via auxiliary power supply (Pin 2)
  • Output Current per Channel- Max 0.5 Amps (Pin 4) / Max 2 Amps (Pin 2)
  • Output Current per Module- Max 9 Amps
  • Galvanically Isolated- Pin 4: No / Pin 2: Yes
  • Protective Circuit- Electronically: Overload protection, short-circuit protection
  • Overload Behavior- Auto off and on switching / Manual restart
Electrical Isolation
  • US (System Supply Voltage) / FE- 500V DC
  • Uaux / FE- 500V DC
  • Bus Connection / FE: 2000V DC
EMC Conformance
  • EMC Directive-2014/30/EU
  • EN 61000-4-2 Electrostatic Discharge (ESD)- Criterion B; 4 kV contact discharge, 8 kV air discharge
  • EN 61000-4-3 Electromagnetic Field- Criterion A; Field intensity: 10 V/m
  • EN 61000-4-4 Fast Transients (Burst)- Criterion B, 2 kV
  • EN 61000-4-5 Surge Voltage- Criterion B; DC supply lines: +/-0.5 kV / +/-0.5 kV (symmetrical/asymmetrical); For I/O ports with cables </= 30m
  • EN 61000-4-6 Conducted immunity- Criterion A; Test voltage 10 V
  • EN 55022 Radio Interference Properties- Class A

Lumberg Automation 0980 ESL 399-121 IO-Link Master M12 Distribution Block