Distributed I/O
Lumberg Automation 934879008 0980 ESL 390-121-DCU1 Lion-P - 8 Port 5 Pin M12 I/O Distributed Control Unit
Lumberg Automation 934879008 0980 ESL 390-121-DCU1 Lion-P is an 8 port 5 pin M12 I/O distributed control unit, with 16 digital input/output channels.
✓ Distributed M12 I/O Control Unit for Machine-Mount Automation
Designed for industrial automation, machine wiring, and field-level device connections
Overview
The Lumberg Automation 934879008 0980 ESL 390-121-DCU1 Lion-P is an 8 port 5 pin M12 I/O distributed control unit, with 16 digital input/output channels. Also has two 4 pin M12 D-coded bus ports & two 5 pin M12 L coded power supply ports. LED indicators show port status.
IP65, IP67, IP69K816 Digital Input/Output
Designed for machine-mounted automation, this distribution block helps centralize field wiring and simplify connections between sensors, actuators, and control systems.
⚙️ Distributed Machine Control
Protocol Support: Ethernet/IP, Profinet, EtherCAT
I/O Capacity: 16 Digital Input/Output
Port Layout: 8
Environmental Rating: IP 65, IP 67, IP 69K
Key Features
- Can perform simple processes for control systems without a high level PLC
- Provides multi – protocol support (Profinet, EtherCAT, & Ethernet/IP)
- Universal channels can be used as inputs or outputs without needing configuring
- Makes fieldbus devices Ethernet ready
- In case of PLC failure, control applications can still operate
- Made to stand up to demanding conditions
- Useful for such applications as automotive, robotics, packaging, and machine building
- Reverse polarity protection
✅ Why Choose This M12 Distribution Block?
This distributed control unit supports local I/O handling near the machine, reducing cabinet wiring while keeping control functions close to the process.
Applications
Use this Lumberg Automation M12 distribution block for machine-mounted field wiring where rugged sensor, actuator, or network connections are needed.
- Ethernet/IP industrial networks
- Profinet machine networks
- EtherCAT machine networks
- Robotics
- Packaging machinery
- Automotive manufacturing
⚠️ Important Installation Info
Check voltage: 24V DC (18-30V DC)
Confirm current limits: Max 2 Amps
Maintain sealing: IP 65, IP 67, IP 69K performance requires properly fitted mating connectors and cable assemblies
Performance Benefits
- Reduces field wiring time by centralizing multiple M12 connections
- Distributed control capability supports simple local process handling near the machine
- Rugged housing materials help protect against harsh industrial conditions
- Machine-mount design helps reduce control cabinet wiring requirements
🔧 Field Wiring Tip
Pair this distribution block with properly coded M12, power, or bus cables to maintain sealing performance and simplify field troubleshooting.
Specifications
|
Brand
|
Lumberg Automation
|
|
Model
|
0980 ESL 390-121-DCU1 Lion-P
|
|
Part Number
|
934879008
|
|
Type
|
8 Port 5 Pin M12 I/O Distributed Control Unit
|
|
Quick Specs
|
IP65, IP67, IP69K / 8 / 16 Digital Input/Output
|
Technical Data
|
Dimensions
|
200mm Length x 59.6mm Width x 30.7mm Height (7.87" x 2.35" x 1.2")
|
|
Device Type
|
I/O Distributed Control Unit
|
|
Protocol
|
Ethernet/IP, Profinet, EtherCAT
|
|
I/O Function
|
16 Digital Input/Output
|
|
Bus Connection
|
4 Pin D-coded M12 LAN
|
|
Power Supply Connection
|
5 Pin L-Coded M12 Power
|
|
I/O Connection
|
5 Pin A-Coded M12
|
|
Housing Material
|
Nickel Plated Die Cast Zinc
|
|
IP Rating
|
IP 65, IP 67, IP 69K
|
|
Potted
|
Yes
|
|
Operating Temperature
|
-20 C to 70 C (-4 F to 158 F)
|
|
Storage Temperature
|
-25 C to 85 C (-13 F to 185 F)
|
|
Humidity
|
5 - 95%
|
|
Mean Time to Failure
|
405 years
|
|
Contact Base Material
|
Gold Plated Copper Alloy
|
|
Contact Bearer Material
|
Polyamide
|
|
O
|
Ring- FKM
|
|
Approvals
|
CE, RoHS, cULus
|
Control System (DCU)
|
Programming Tool
|
LDmicro
|
|
Programming Language
|
LAD: Ladder Logic
|
|
Program Deployment
|
via Webserver / HTTP
|
|
Processor
|
200 MHz RISC CPU
|
|
Performance
|
min 10ms
|
|
Program Memory
|
max 99 Rungs / max. 99 Bit Variables / max. 99 Integer Variables
|
|
Flash Memory
|
16 MB
|
|
Persistent Memory
|
No
|
|
Realtime Clock
|
No
|
|
Operation Modes
|
I/O Slave/Device, Mixed DCU/PLC Mode, Standalone DCU Mode
|
|
Communication Interface
|
Ethernet/TCP
|
|
Webserver
|
Integrated
|
Profinet
|
Number of Connections
|
2
|
|
Specification
|
V2.3X
|
|
Conformance Class
|
C
|
|
Performance Class
|
RT (switch supports IRT)
|
|
Netload Class
|
III
|
|
Transmission Rate
|
Fast Ethernet (10/100 Mbit/s), Full Duplex
|
|
Transmission Method
|
100BaseTX, with auto-negotiation & auto-crossing
|
|
Cycle Time / Update Rate
|
Min 1 ms
|
|
Addressing
|
DCP
|
|
Fast Startup
|
Supported, <= 1000 ms
|
|
Media Redundancy Protocol
|
Supported, MRP client
|
|
Shared Device
|
Not Supported
|
|
Topology Detection
|
LLDP, SNMP V1
|
|
Easy Device Replacement
|
Supported, based on LLDP
|
|
Supported Network Protocols
|
ARP, HTTP, Ping, SNMP V1, TCP/IP
|
Ethernet/IP
|
Number of Connections
|
2
|
|
Specification
|
CIP V3.1x, EIP Adaption of CIP V1.2x
|
|
Transmission Rate
|
Fast Ethernet (10/100 Mbit/s), Full Duplex
|
|
Transmission Method
|
100BaseTX, with auto-negotiation & auto-crossing
|
|
Cycle Time / Update Rate
|
Min 1 ms
|
|
Addressing
|
BootP, DHCP, Rotary Address Switches
|
|
Address Switches Range
|
0 to 255 dec
|
|
Connection Types
|
Exclusive Owner, Input Only, Listen Only
|
|
CIP Msg Connection Limit
|
6
|
|
CIP I/O Connection Limit
|
3
|
|
Device Level Ring
|
Supported, Beacon based
|
|
Quick Connect
|
Supported, <= 500ms
|
|
Supported Network Protocols
|
ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP
|
EtherCAT
|
Number of Connections
|
2
|
|
Specification
|
ETG.1000 V1.2
|
|
Transmission Rate
|
Fast Ethernet (10/100 Mbit/s), Full Duplex
|
|
Transmission Method
|
100BaseTX, with auto-negotiation & auto-crossing
|
|
Cycle Time / Update Rate
|
Min 250 µs
|
|
Addressing
|
Auto-increment addressing, fixed position addressing
|
|
Mailbox Protocols
|
CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE)
|
|
Supported Network Protocols
|
Over EoE: HTTP, Ping, TCP/IP
|
Power Supply Connection Module Supply
|
Number of Connections
|
2
|
|
Current Carrying Capacity
|
Max 16 Amps
|
|
Nominal Voltage
|
24V DC (18-30V DC)
|
|
Current Consumption
|
120 mA @ 24V DC
|
Connection Sensor Supply
|
Current Carrying Capacity
|
Max 16 Amps
|
|
Nominal Voltage
|
24V DC (18-30V DC)
|
Connection Actuator Supply (via Module Supply Connection)
|
Current Carrying Capacity
|
Max 16 Amps
|
|
Nominal Voltage
|
24V DC (18-30V DC)
|
Digital Input Channels
|
Number of Channels
|
Up to 16, universal
|
|
Number of Ports
|
8
|
|
Channel Type
|
Type 3 according to IEC 61131-2
|
|
Input Wiring
|
2, 3, 4 wire
|
|
Nominal Voltage
|
24V DC
|
|
Nominal Current
|
5 mA
|
|
Sensor Current Supply
|
Max. 500 mA per port
|
|
Sensor Type
|
PNP
|
|
Input Voltage Range
|
-3V DC to 5 V DC (0 signal), 11V DC to 30V DC (1 signal)
|
|
Input Filter Time
|
3ms, fixed
|
|
Protective Circuit
|
Electronically: Overload Protection, Short-circuit Protection
|
Digital Output Channels
|
Number of Channels
|
Up to 16, universal
|
|
Number of Ports
|
8
|
|
Channel Type
|
P-Switching
|
|
Output Wiring
|
2 wire
|
|
Nominal Voltage
|
24V DC via UL (actuator power supply)
|
|
Output Current per Channel
|
Max 2 Amps
|
|
Output Current per Module
|
Max 9 Amps
|
|
Protective Circuit
|
Electronically: Overload protection, short-circuit protection
|
|
Overload Behavior
|
Auto off and on switching / Manual restart
|
Electrical Isolation
|
US (System Supply Voltage) / FE
|
500V DC
|
|
UL / FE
|
500V DC
|
|
Bus Connection / FE
|
2000V DC
|
EMC Conformance
|
EMC Directive
|
2014/30/EU
|
|
EN 61000
|
4-2 Electrostatic Discharge (ESD)- Criterion B; 4 kV contact discharge, 8 kV air discharge
|
|
EN 61000
|
4-3 Electromagnetic Field- Criterion A; Field intensity: 10 V/m
|
|
EN 61000
|
4-4 Fast Transients (Burst)- Criterion B, 2 kV
|
|
EN 61000
|
4-5 Surge Voltage- Criterion B; DC supply lines: +/-0.5 kV / +/-0.5 kV (symmetrical/asymmetrical); For I/O ports with cables <= 30m
|
|
EN 61000
|
4-6 Conducted immunity- Criterion A; Test voltage 10 V
|
|
EN 55022 Radio Interference Properties
|
Class A
|
|
|
 |
 |
 |
 |

|