The Lumberg Automation 934879008 0980 ESL 390-121-DCU1 Lion-P is an 8 port 5 pin M12 I/O distributed control unit, with 16 digital input/output channels. Also has two 4 pin M12 D-coded bus ports & two 5 pin M12 L coded power supply ports. LED indicators show port status.

Features

  • Can perform simple processes for control systems without a high level PLC
  • Provides multi-protocol support (Profinet, EtherCAT, & Ethernet/IP)
  • Universal channels can be used as inputs or outputs without needing configuring
  • Makes fieldbus devices Ethernet ready
  • In case of PLC failure, control applications can still operate
  • Made to stand up to demanding conditions
  • Useful for such applications as automotive, robotics, packaging, and machine building
  • Reverse polarity protection

Lumberg Automation 0980 ESL 390-121-DCU1 Manuals

Specifications

  • Dimensions- 200mm Length x 59.6mm Width x 30.7mm Height (7.87" x 2.35" x 1.2")
  • Device Type- I/O Distributed Control Unit
  • Protocol- Ethernet/IP, Profinet, EtherCAT
  • I/O Function- 16 Digital Input/Output
  • Bus Connection- 4 Pin D-coded M12 LAN
  • Power Supply Connection- 5 Pin L-Coded M12 Power
  • I/O Connection- 5 Pin A-Coded M12
  • Housing Material- Nickel Plated Die Cast Zinc
  • IP Rating- IP 65, IP 67, IP 69K
  • Potted- Yes
  • Operating Temperature- -20 C to 70 C (-4 F to 158 F)
  • Storage Temperature- -25 C to 85 C (-13 F to 185 F)
  • Humidity- 5 - 95%
  • Mean Time to Failure- 405 years
  • Contact Base Material- Gold Plated Copper Alloy
  • Contact Bearer Material- Polyamide
  • O-Ring- FKM
  • Approvals- CE, RoHS, cULus
Control System (DCU)
  • Programming Tool- LDmicro
  • Programming Language- LAD: Ladder Logic
  • Program Deployment- via Webserver / HTTP
  • Processor- 200 MHz RISC CPU
  • Performance- min 10ms
  • Program Memory- max 99 Rungs / max. 99 Bit Variables / max. 99 Integer Variables
  • Flash Memory- 16 MB
  • Persistent Memory- No
  • Realtime Clock- No
  • Operation Modes- I/O Slave/Device, Mixed DCU/PLC Mode, Standalone DCU Mode
  • Communication Interface- Ethernet/TCP
  • Webserver- Integrated
Profinet
  • Number of Connections- 2
  • Specification- V2.3X
  • Conformance Class- C
  • Performance Class- RT (switch supports IRT)
  • Netload Class- III
  • Transmission Rate- Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method- 100BaseTX, with auto-negotiation & auto-crossing
  • Cycle Time / Update Rate- Min 1 ms
  • Addressing- DCP
  • Fast Startup- Supported, </= 1000 ms
  • Media Redundancy Protocol- Supported, MRP client
  • Shared Device- Not Supported
  • Topology Detection- LLDP, SNMP V1
  • Easy Device Replacement- Supported, based on LLDP
  • Supported Network Protocols- ARP, HTTP, Ping, SNMP V1, TCP/IP
Ethernet/IP
  • Number of Connections- 2
  • Specification- CIP V3.1x, EIP Adaption of CIP V1.2x
  • Transmission Rate- Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method- 100BaseTX, with auto-negotiation & auto-crossing
  • Cycle Time / Update Rate- Min 1 ms
  • Addressing- BootP, DHCP, Rotary Address Switches
  • Address Switches Range- 0 to 255 dec
  • Connection Types- Exclusive Owner, Input Only, Listen Only
  • CIP Msg Connection Limit- 6
  • CIP I/O Connection Limit- 3
  • Device Level Ring- Supported, Beacon based
  • Quick Connect- Supported, </= 500ms
  • Supported Network Protocols- ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP
EtherCAT
  • Number of Connections- 2
  • Specification- ETG.1000 V1.2
  • Transmission Rate- Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method- 100BaseTX, with auto-negotiation & auto-crossing
  • Cycle Time / Update Rate- Min 250 µs
  • Addressing- Auto-increment addressing, fixed position addressing
  • Mailbox Protocols- CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE)
  • Supported Network Protocols- Over EoE: HTTP, Ping, TCP/IP
Power Supply
Connection Module Supply

  • Number of Connections- 2
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
  • Current Consumption- 120 mA @ 24V DC
Connection Sensor Supply
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
Connection Actuator Supply (via Module Supply Connection)
  • Current Carrying Capacity- Max 16 Amps
  • Nominal Voltage- 24V DC (18-30V DC)
Digital Input Channels
  • Number of Channels- Up to 16, universal
  • Number of Ports- 8
  • Channel Type- Type 3 according to IEC 61131-2
  • Input Wiring- 2, 3, 4 wire
  • Nominal Voltage- 24V DC
  • Nominal Current- 5 mA
  • Sensor Current Supply- Max. 500 mA per port
  • Sensor Type- PNP
  • Input Voltage Range- -3V DC to 5 V DC (0 signal), 11V DC to 30V DC (1 signal)
  • Input Filter Time- 3ms, fixed
  • Protective Circuit- Electronically: Overload Protection, Short-circuit Protection
Digital Output Channels
  • Number of Channels- Up to 16, universal
  • Number of Ports- 8
  • Channel Type- P-Switching
  • Output Wiring- 2 wire
  • Nominal Voltage-24V DC via UL (actuator power supply)
  • Output Current per Channel- Max 2 Amps
  • Output Current per Module- Max 9 Amps
  • Protective Circuit- Electronically: Overload protection, short-circuit protection
  • Overload Behavior- Auto off and on switching / Manual restart
Electrical Isolation
  • US (System Supply Voltage) / FE- 500V DC
  • UL / FE- 500V DC
  • Bus Connection / FE: 2000V DC
EMC Conformance
  • EMC Directive-2014/30/EU
  • EN 61000-4-2 Electrostatic Discharge (ESD)- Criterion B; 4 kV contact discharge, 8 kV air discharge
  • EN 61000-4-3 Electromagnetic Field- Criterion A; Field intensity: 10 V/m
  • EN 61000-4-4 Fast Transients (Burst)- Criterion B, 2 kV
  • EN 61000-4-5 Surge Voltage- Criterion B; DC supply lines: +/-0.5 kV / +/-0.5 kV (symmetrical/asymmetrical); For I/O ports with cables </= 30m
  • EN 61000-4-6 Conducted immunity- Criterion A; Test voltage 10 V
  • EN 55022 Radio Interference Properties- Class A