Comparison Chart for Lumberg Automation M12 Distribution Blocks
Active and Passive Models
Lumberg Automation M12 Distribution Block Comparison
Compare M12 distribution blocks by network protocol, I/O capacity, connector type, housing width, and environmental protection. Use the guide below to narrow the options, then select a part number to view product details.
Choose an active M12 block when...
The field block must exchange data directly with a control network or IO-Link system. Compare supported protocols, available input/output channels, and the required power and bus connectors.
Choose a passive M12 block when...
Several field-device signals need to be consolidated into one home-run cable or M23 connection. Compare port count, cable length, LED indication, PNP/NPN configuration, and shielding.
Quick M12 Distribution Block Selection Checklist
1. Function: Active network node or passive wiring block
2. Capacity: Required inputs, outputs, or IO-Link ports
3. Connections: Match power, bus, and field-device interfaces
4. Environment: Verify the needed IP rating and housing width
Active M12 Distribution Blocks
Network-capable models for IO-Link, multiprotocol Ethernet, PROFINET, and EtherNet/IP applications.
I/O16 inputs/outputs
Power1 × M12, L-coded
Bus1 × M12, A-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O16 inputs
PowerVia bus connection
Bus1 × M12, A-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O10 inputs, 6 outputs
PowerVia bus connection
Bus1 × M12, A-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O4 inputs, 8 IO-Link ports
Power2 × M12, L-coded
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction30 mm metal housing; IP65/IP67/IP69K
I/O16 inputs/outputs
Power2 × M12, L-coded
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O16 inputs/outputs
Power2 × M12, L-coded
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O4 inputs, 4 outputs, 8 IO-Link ports
Power2 × M12, L-coded
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67/IP69K
I/O16 inputs
Power2 × 7/8", 5-pole
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67
I/O16 inputs
Power2 × 7/8", 4-pole
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67
I/O8 inputs, 8 outputs
Power2 × 7/8", 4-pole
Bus2 × M12, D-coded
I/O ports8 × M12, A-coded
Construction60 mm metal housing; IP65/IP67
Passive M12 Distribution Blocks
Four- and eight-port blocks with M23 or fixed control-cable interfaces for streamlined field wiring.
InterfaceM23 plug
I/O ports4 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
InterfaceM23 plug
I/O ports8 × M12, 5-pole
ConfigurationPNP
Construction60 mm zinc die-cast housing; IP65/IP67
InterfaceM23 plug
I/O ports8 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
Interface10 m control cable
I/O ports4 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
Interface5 m control cable
I/O ports4 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
Interface10 m control cable
I/O ports8 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
Interface5 m control cable
I/O ports8 × M12, 5-pole
ConfigurationPNP; LED
Construction60 mm zinc die-cast housing; IP65/IP67
Understanding the Comparison
An active Lumberg Automation M12 distribution block processes and exchanges field I/O data through an industrial communication protocol. A passive block acts as a centralized wiring point, routing connected sensor and actuator signals through an M23 interface or fixed control cable.
Before ordering: Confirm the controller protocol, signal direction, port count, connector coding, and power interface. IP ratings apply only when the block is installed with correctly rated mating connectors and unused ports are properly sealed.
|