Saginaw SCE-14087CHQRFG Fiberglass Junction Enclosure with padlock latches: 15.75" H x 8.75" W x 6.81" D
Non-metallic junction enclosure for electrical equipment in washdown, outdoor and corrosive locations. Its hinged cover with gasket and padlock latches help shield components from water, oil, dirt and airborne contaminants. Rated NEMA 4, 4X, 12 and 13 and IP66. Sub-panel sold separately.
✅ Built for Washdown and Corrosive Environments
The Saginaw SCE-14087CHQRFG protects control, power-distribution and instrumentation components where moisture, chemicals, salt air or severe weather can damage a conventional enclosure. Its non-metallic body is suited to industrial plants, mines, oil and gas facilities, marine locations and exposed equipment installations.
High-Strength Fiberglass Protection with Open Side-Wall Access
This Saginaw fiberglass junction enclosure is compression molded from polyester reinforced with glass fibers. The material delivers strong impact performance at less weight than steel, resists corrosion and many chemicals, and electrically isolates installed equipment. Its flame-retardant construction meets UL94-5V requirements and remains suitable for service from -70°F to +270°F.
The Junction Series pairs a flange-mounted base with a cover that extends slightly over the enclosure edges. The hinged, latched cover reinforces the perimeter while leaving the side walls clear for cable entries, conduit fittings and controls. Molded mounting strips and panel inserts support organized component installation, and the enclosure can accept a standard back panel when one is required.
☀️ Outdoor UV Stability
Engineered to limit sunlight-related fading and material breakdown, helping preserve the enclosure outdoors
🧪 Corrosion Defense
Withstands harsh weather, moisture and many chemical exposures without the rust concerns associated with steel
🛡️ Strength Without Steel Weight
Glass-reinforced construction provides impact resistance and structural durability while simplifying handling
⚡ Electrically Insulating
The nonconductive housing adds electrical isolation around sensitive controls, terminals and instruments
Key Features & Benefits
- Fiberglass-Reinforced Polyester Body: Provides a durable, lightweight alternative to metal enclosures for demanding electrical installations
- Two quick-release padlock latches: Secure the cover while allowing authorized personnel to add a padlock
- Continuous Stainless Steel Hinge: Supports the cover along its full hinged edge for repeatable access
- Water- and Oil-Resistant Gasket: Helps prevent liquid and contaminant entry when the cover is properly closed
- Flat Side Walls: Simplify the placement of cable glands, conduit hubs, disconnects and operator devices
- Built-In Mounting Provisions: Molded strips and panel-mount inserts help reduce enclosure preparation
- Outdoor and Chemical Resistance: The FRP formulation resists sunlight, corrosion, harsh weather and many industrial chemicals
- Wide Temperature Capability: Suitable for specified use from -70°F through +270°F
- Environmental Certifications: NEMA 4, 4X, 12 and 13; UL Listed Type 4, 4X and 12; CSA Type 4, 4X and 12; IEC 60529; IP66
- Sub-Panel Sold Separately: Compatible back panel linked below
Specifications
|
Part Number
|
SCE-14087CHQRFG
|
|
Manufacturer
|
Saginaw Control & Engineering
|
|
Enclosure Type
|
Hinged fiberglass electrical junction enclosure
|
|
Material
|
Compression-molded, glass-fiber-reinforced polyester (FRP)
|
|
Dimensions
|
15.75" H x 8.75" W x 6.81" D
(400mm x 222.25mm x 173mm)
|
|
Latch
|
Two quick-release padlock latches
|
|
Hinge
|
Continuous stainless steel hinge
|
|
Door Seal
|
Water- and oil-resistant gasket
|
|
Mounting Features
|
Molded mounting strips and built-in panel-mount inserts
|
|
NEMA Ratings
|
Type 4, 4X, 12 and 13
|
|
UL Listing
|
UL Listed Type 4, 4X and 12
|
|
CSA Ratings
|
Type 4, 4X and 12
|
|
IEC / IP Rating
|
IEC 60529 / IP66
|
|
Flame Performance
|
UL94-5V
|
|
Operating Range
|
-70°F to +270°F
|
|
Sub-Panel
|
Sold separately; accepts standard back-panel mounting
|
📐 Cover Design
The cover extends over the flange-mounted base to strengthen the enclosure perimeter. Because the hinge and latches are integrated with this cover-and-base arrangement, the side walls remain available for field modifications and component placement.
🔧 Panel and Installation Notes
A sub-panel is not included. Use the built-in panel-mount inserts with a compatible standard back panel, then plan cable-entry locations so wiring clearances and the enclosure seal are maintained. Select fittings with environmental ratings appropriate for the installation.
🏭 Typical Applications
Industrial controls: House terminal blocks, relays, sensor interfaces and small control assemblies in wet or dusty production areas.
Mining and energy: Protect electrical junctions and instrumentation from moisture, weather and corrosive exposure.
Marine and coastal equipment: Avoid metal-enclosure corrosion in salt-air and high-humidity locations.
🧰 Why Use a Fiberglass Electrical Enclosure?
Fiberglass-reinforced polyester combines corrosion resistance, impact strength and electrical insulation in one housing. It is easier to handle than a comparable steel enclosure and does not require paint to prevent rust, making it practical where weather, chemicals or frequent washdowns increase maintenance demands.
Find the Right Enclosure Size and Rating
Compare enclosure materials, dimensions and environmental ratings before selecting components and cable-entry hardware.
|
|
 |
 |
 |
 |


|