Home > Circuit Breakers >

IMO UB10D3001A Miniature Circuit Breaker, 1 A, D Curve, 3 Pole, Din Rail Mount


IMO UB10D3001A Miniature Circuit Breaker, 1 A, D Curve, 3 Pole, Din Rail Mount
IMO UB10D3001A Miniature Circuit Breaker, 1 A, D Curve, 3 Pole, Din Rail Mount
 
Alternative Views:


Price: $89.53
Note: Lead Time: 2-3 Weeks
MFG P/N: UB10D3001A
MFG: IMO Precision Controls
Weight (lbs): 0.82

Quantity in Stock :(Out of Stock)


Availability:
Out of Stock
Product Code: UB10D3001A
Qty:

Description
 

IMO UB10D3001A 1A UL 489 Circuit Breaker, 3-pole, D Curve, 10kA

1A 3-pole D-curve miniature circuit breaker with thermo-magnetic protection, 10kA breaking capacity, DIN-rail mounting, and UL 489 approval.

Why Choose the IMO UB10D3001A Circuit Breaker?

The IMO Precision Controls UB10D3001A is a 1A 3-pole miniature circuit breaker for very low-current three-pole AC control and transformer branches requiring tolerance for brief high inrush. It is rated for 480Y/277V AC and provides UL 489 branch-circuit protection in industrial control panels, machinery, and distribution equipment when applied within its electrical ratings.

Thermo-magnetic operation combines a thermal response for sustained overloads with rapid magnetic response during severe faults. The D curve delays magnetic tripping until a higher multiple of rated current, helping prevent nuisance trips on loads with brief, high startup current. A contact-position indicator provides a clear visual reference during inspection and troubleshooting.

⚔ 1A Rating

Protects a correctly sized 3-pole branch circuit rated for 1A

šŸ“‰ D Trip Curve

10–20 Ɨ In magnetic range supports loads with high startup current

šŸ›”ļø 10kA Capacity

Provides 10kA short-circuit breaking capacity for suitable electrical systems

āœ… UL 489 Approved

Approved for branch-circuit protection when selected and installed correctly

āš ļø Coordinate the 1A 3-pole Breaker with the Load

Confirm the 1A rating, 3-pole configuration, conductor current, 480Y/277V AC rating, available fault current, D trip curve, ambient conditions, and equipment requirements before installation. A D-curve breaker does not replace separate motor-overload protection when the equipment or applicable code requires it.

šŸ“‹ 1A D-Curve Magnetic Trip Range

The D-curve magnetic element operates at 10–20 times rated current. For the UB10D3001A, this corresponds to an instantaneous magnetic range of approximately 10–20A. The thermal element responds to sustained overloads. Confirm coordination with normal startup current and upstream or downstream protective devices.

Key Features & Benefits

  • 3-pole DIN-rail mounting configuration
  • Rated for 480Y/277V AC
  • Approximate magnetic trip range of 10–20A
  • Thermo-magnetic overload and short-circuit protection
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range with 2.5 Nm fastening torque
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 2.06" Width x 2.64" Depth (108mm x 52.5mm x 67mm)
Rated Current 1 Amp
Voltage Rating 480Y / 277V AC
Number of Poles 3
Tripping Curve D (10-20 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s² @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

šŸ“‹ 3-pole Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that conductor current and connected equipment are compatible with a 1A protective device.

2. Verify Pole and Voltage Requirements: Confirm that the circuit requires 3 poles and operates within the 480Y/277V AC rating.

3. Check Fault and Inrush Current: Verify the available fault current, 10kA breaking capacity, and compatibility of the D curve with normal startup demand.

4. Mount and Terminate: Install on DIN rail using conductors within the specified 18–3 AWG range and apply the listed 2.5 Nm terminal torque.

5. Inspect Before Energizing: Verify wiring, labeling, protective-device coordination, and code compliance before commissioning.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

šŸ­ Typical Uses for the 1A 3-pole D-Curve Breaker

• Low-current three-phase control branches
• Small control-transformer primary circuits
• Sensitive inductive equipment
• Three-pole AC circuits requiring 1A D-curve protection

šŸ“š Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




Seifert 400030000 Filter Assembly 250mm x 250mm Gray $30.57