IMO UB10C2010A Miniature Circuit Breaker, 10 A, C Curve, 2 Pole, Din Rail Mount


IMO UB10C2010A Miniature Circuit Breaker, 10 A, C Curve, 2 Pole, Din Rail Mount
IMO UB10C2010A Miniature Circuit Breaker, 10 A, C Curve, 2 Pole, Din Rail Mount
 
Alternative Views:


Price: $59.71
Note: Ships in 4-7 Business Days
MFG P/N: UB10C2010A
MFG: IMO Precision Controls
Weight (lbs): 0.55

Quantity in Stock :28


Availability:
In Stock
Product Code: UB10C2010A
Qty:

Description
 

IMO UB10C2010A 10A UL 489 Circuit Breaker, 2-pole, C Curve, 10kA, 480Y/277V AC, 96V DC

10A 2-pole miniature circuit breaker with C-curve thermo-magnetic protection, 10kA interrupting capacity, DIN-rail mounting, and UL 489 approval.

Why Choose the IMO UB10C2010A Circuit Breaker?

The IMO Precision Controls UB10C2010A is a 10A 2-pole miniature circuit breaker for two-pole machinery, power-supply, and control-panel branches engineered for a 10A breaker. It is rated for 480Y/277V AC or 96V DC and provides UL 489 branch-circuit protection in industrial control panels, machinery, and distribution equipment when applied within its electrical ratings.

Thermo-magnetic operation combines a thermal response for sustained overloads with rapid magnetic tripping during severe faults. The C-curve characteristic is designed for correctly engineered loads with moderate inrush, while the contact-position indicator gives maintenance personnel a clear visual reference during inspection and troubleshooting.

⚔ 10A Rating

Protects a correctly sized circuit rated for 10A

šŸ”— 2 Poles

Provides 2-pole protection for a properly designed two-conductor branch

šŸ›”ļø 10kA Capacity

Offers 10kA short-circuit breaking capacity for suitable electrical systems

āœ… UL 489 Approved

Approved for branch-circuit protection when selected and installed correctly

āš ļø Verify the Complete 10A 2-pole Circuit Design

Do not select this breaker from current rating alone. Confirm the 10A rating, 2-pole configuration, conductor current, load requirements, 480Y/277V AC or 96V DC rating, available fault current, C trip curve, ambient conditions, and applicable electrical codes before installation.

šŸ“‹ 10A C-Curve Magnetic Trip Range

The C-curve magnetic element operates at 5–10 times rated current. For the UB10C2010A, that corresponds to a specified instantaneous magnetic range of approximately 50–100A. The thermal element provides overload response below severe fault levels. Always confirm coordination with normal startup current and upstream or downstream protective devices.

Key Features & Benefits

  • Rated for 480Y/277V AC or 96V DC
  • C-curve magnetic trip range of approximately 50–100A
  • Thermo-magnetic overload and short-circuit protection
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range with 2.5 Nm fastening torque
  • 20,000 mechanical and 6,000 electrical operations
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 1.38" Width x 2.64" Depth (108mm x 35mm x 67mm)
Rated Current 10 Amp
Voltage Rating 480Y / 277V AC / 96V DC
Number of Poles 2
Tripping Curve C (5-10 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s² @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

šŸ“‹ 2-pole Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that conductor current and connected equipment are compatible with a 10A protective device.

2. Verify Pole and Voltage Requirements: Confirm that the circuit requires 2 poles and operates within the 480Y/277V AC or 96V DC rating.

3. Check Fault and Inrush Current: Verify the available fault current, 10kA breaking capacity, and compatibility of the C curve with normal startup demand.

4. Mount and Terminate: Install on DIN rail using conductors within the specified 18–3 AWG range and apply the listed 2.5 Nm terminal torque.

5. Inspect Before Energizing: Verify wiring, labeling, protective-device coordination, and code compliance before commissioning.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

šŸ­ Typical Uses for the 10A 2-pole Breaker

• Machinery auxiliary-power circuits
• Industrial power-supply input branches
• Two-wire equipment and control circuits
• AC or DC branches requiring 10A UL 489 protection

šŸ“š Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




Sealcon HP-36-BR-B PG 36 Nickel Plated Brass Hex Plug w/ O-Ring $15.06
Mencom MDC-4FR-PCB-R M12 Receptacle, 4 Pole, Female Right Angle, 4A, M12 $16.32
Z+F V30AE001667 Gray Polypropylene Insulated End Sleeve, 26 AWG, 0.39" Length $0.02
Sealcon CD13A1-BK Black PG 13 / 13.5 Dome 3 Hole .08" (2 mm) Insert Cord Grip $3.64
Sealcon CD63MR-BK Black M63 Dome 1.14" - 1.38" (39 - 35 mm) O.D. Cord Grip $29.79
Saginaw SCE-9PBI Push Button Enclosure, 9 Position, 22.5mm $122.30
Sealcon 1.089.0907.19 PG 9, M16, 3/8" NPT, 4 Hole .07" (1.7 mm) Insert $2.20