Home > Relays > Percentage Timers >

Macromatic PTA2001HB Percentage Timer, 1 Hr, 120V AC, No Memory


Macromatic Percentage Timer, 1 Hour, 120V AC, No Memory
Macromatic PTA2001HB Percentage Timer, 1 Hr, 120V AC, No Memory
 
Alternative Views:


Price: $164.20
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: PTA2001HB
MFG: Macromatic
Weight (lbs): 0.14



Availability:
In Stock
Product Code: PTA2001HB
Qty:

Description
 

The Macromatic PTA2001HB is a percentage timer. This panel mount timer relay has an input voltage of 120V AC with an output of 10A SPNO and a timer range of 1 hour. It is used for instances when the ON time when used a percentage of a total cycle time has to be adjustable. This timer is useful for applications such as irrigation, heating & cooling, motors, and chemical feeding. It has an integrated potentiometer for time delay adjustment. An LED indicator on top shows the relay status. Termination is possible with bare wire or crimp terminals. Mounting hardware included. Note: Image is for reference. Actual part may differ.

Specifications

  • Relay Function- Percentage Timer w/o Memory
  • Relay Timer Range- 1 Hour
  • Input Voltage- 120V AC
  • Output- 10A SPNO
  • Voltage Tolerance- +10/-15% of nominal at 50/60 Hz
  • Load- Max of 3 VA
  • Setting Accuracy- +/- 2%
  • Setting Precision- +/- 1% of total cycle time
  • Dial Resolution- Dial settings marked in 1% increments
  • Repeat Accuracy- +/- 0.1% or +/- 0.04 seconds, whichever is greater
  • Reset Time- 300ms
  • Start Up Time- 0.05 seconds
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPNO, 1/4 HP @ 120VAC
  • Lifespan- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Termination- Pressure Clamp Screw Terminals, #12-22 AWG wire, solid, stranded wire; Recommended tightening torque 7 in-lbs. (12 in-lbs max)
  • Dimensions- 3.5" Height x 3.5" Width x 4.1" Length
  • Approvals- UL & CUL Listed, CE

When the input voltage is introduced, the percentage timer relay energizes and the ON time delay (t1) starts. T1 is adjustable as a percentage of the total ON/OFF cycle time (t2), which is one hour. When t1 ends, the relay de-energizes for the rest of the timing cycle. The ON/OFF sequence will then repeat. This continues until the input voltage is removed. The sequence resets itself if the input voltage is taken out. 100% will keep the output constantly energized and 0% will keep it constantly de-energized. The LED on top is steady during the OFF sequence and blinks during the ON sequence.

Macromatic Percentage Timer Installation Manual

PTA2001HB 1 Hour 120V Percentage Timer without Memory


Related Products
Macromatic 70600 Terminal Cover for Percentage Timers
Price: $0.92

Add
Macromatic Terminal Cover



Kacon T22-271GD4 22 mm Green Momentary Push Button, SPDT, 24V DC LED $32.64
Euri Lighting EB40-11W5000CEC 11W BR40 LED Flood Light, 3000K $6.38
Mueller AI-50192N Red Nylon Insulated Female Quick Disconnect Terminal, 22-18 AWG, .187" X .02" $0.17
ILME CTSF-40L CTS Series Insert, Female, Size 77.27, 40 Pin, 10A, Spring Left $187.87
Macromatic PMP120 Multi-Detection 120V Phase Monitor Relay $63.23
Saginaw SCE-48EL3616LPPL Single Door Enclosure w/ 3 Point Hardware, 48" x 36" x 16" $1,164.49
ILME CTSF-40R CTS Series Insert, Female, Size 77.27, 40 Pin, 10A, Spring Right $187.87
Boxco BC-CGS-202016 Enclosure, 200x200x160, Solid Gray Screw Cover, Polycarbonate $42.87