Home > Relays > Time Delay Relays >

Macromatic THR-16162-34J Encapsulated Time Delay Relay, Delayed Interval, 120V, 0.1-10 Hr, Internal Jumper


Macromatic THR-16162-34J Time Delay Relay
Macromatic THR-16162-34J Encapsulated Time Delay Relay, Delayed Interval, 120V, 0.1-10 Hr, Internal Jumper
 
Alternative Views:


Price: $32.04
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-16162-34J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-16162-34J
Qty:

Description
 

The Macromatic THR-16162-34J is a delayed interval Time Delay Relay. This encapsulated relay has an input voltage of 120V AC/DC. It has an adjustable time range of 0.1-10 hours. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Delayed Interval
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 0.1 - 10 Hrs
  • Input Voltage- 120V AC/DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50%
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.01 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With Delayed Interval, the OFF time delay starts along with the input voltage. After that, the ON time delay starts and the relay is energized for the duration of the time delay. When the ON time delay finishes, the relay de-energizes. The input voltage has to be re-introduced to restart the cycle.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic 120V 0.1-10 Hour Delayed Interval Time Delay Relay with Jumper THR-16162-34J




Kacon B30-21R-F65 65 mm Momentary Push Button, Red, Full Guard $32.34
HTP M12 Panel Mount Connector w/ Flange, Male, 5 Pole $21.60
Lumberg Automation RST 5L-949/5 M M12 Power Cordset, Male Straight, 5 Pin, L Coding, 5 M $67.17
Kacon T19-312 19 mm Maintained Push Button, 2NO/2NC $26.19
Kacon T19-372BA2 19 mm Blue Maintained Push Button, 2NO/2NC, 110/220V AC LED $28.69
IMO UB10C1032A Miniature Circuit Breaker, 32 A, C Curve, 1 Pole, Din Rail Mount $29.89
Sealcon CF17MA-BR Nickel Plated Brass M16 Flex .20" - .39" (5 - 10 mm) O.D. Cord Grip $27.93
IMO UB10C1016A Miniature Circuit Breaker, 16 A, C Curve, 1 Pole, Din Rail Mount, UL 489 $29.89
Macromatic TCP2G100 Over Temperature & Seal Leak Relay, 120V, 4.7K to 100K, Automatic Reset $71.96