IMO UB10C2007A Miniature Circuit Breaker, 7 A, C Curve, 2 Pole, Din Rail Mount


IMO UB10C2007A Miniature Circuit Breaker, 7 A, C Curve, 2 Pole, Din Rail Mount
IMO UB10C2007A Miniature Circuit Breaker, 7 A, C Curve, 2 Pole, Din Rail Mount
 
Alternative Views:


Price: $59.71
Note: Ships in 4-7 Business Days
MFG P/N: UB10C2004A
MFG: IMO Precision Controls
Weight (lbs): 0.55

Quantity in Stock :18


Availability:
In Stock
Product Code: UB10C2007A
Qty:

Description
 

IMO UB10C2007A 7A UL 489 Circuit Breaker, 2-pole, C Curve, 10kA, 480Y/277V AC, 96V DC

7A 2-pole miniature circuit breaker with C-curve thermo-magnetic protection, 10kA interrupting capacity, DIN-rail mounting, and UL 489 approval.

Why Choose the IMO UB10C2007A Circuit Breaker?

The IMO Precision Controls UB10C2007A is a 7A 2-pole miniature circuit breaker for equipment and machine-control branches that call for a less-common 7A two-pole protective device. It is rated for 480Y/277V AC or 96V DC and provides UL 489 branch-circuit protection in industrial control panels, machinery, and distribution equipment when applied within its electrical ratings.

Thermo-magnetic operation combines a thermal response for sustained overloads with rapid magnetic tripping during severe faults. The C-curve characteristic is designed for correctly engineered loads with moderate inrush, while the contact-position indicator gives maintenance personnel a clear visual reference during inspection and troubleshooting.

⚡ 7A Rating

Protects a correctly sized circuit rated for 7A

🔗 2 Poles

Provides 2-pole protection for a properly designed two-conductor branch

🛡️ 10kA Capacity

Offers 10kA short-circuit breaking capacity for suitable electrical systems

✅ UL 489 Approved

Approved for branch-circuit protection when selected and installed correctly

⚠️ Verify the Complete 7A 2-pole Circuit Design

Do not select this breaker from current rating alone. Confirm the 7A rating, 2-pole configuration, conductor current, load requirements, 480Y/277V AC or 96V DC rating, available fault current, C trip curve, ambient conditions, and applicable electrical codes before installation.

📋 7A C-Curve Magnetic Trip Range

The C-curve magnetic element operates at 5–10 times rated current. For the UB10C2007A, that corresponds to a specified instantaneous magnetic range of approximately 35–70A. The thermal element provides overload response below severe fault levels. Always confirm coordination with normal startup current and upstream or downstream protective devices.

Key Features & Benefits

  • Rated for 480Y/277V AC or 96V DC
  • C-curve magnetic trip range of approximately 35–70A
  • Thermo-magnetic overload and short-circuit protection
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range with 2.5 Nm fastening torque
  • 20,000 mechanical and 6,000 electrical operations
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 1.38" Width x 2.64" Depth (108mm x 35mm x 67mm)
Rated Current 7 Amp
Voltage Rating 480Y / 277V AC / 96V DC
Number of Poles 2
Tripping Curve C (5-10 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s² @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

📋 2-pole Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that conductor current and connected equipment are compatible with a 7A protective device.

2. Verify Pole and Voltage Requirements: Confirm that the circuit requires 2 poles and operates within the 480Y/277V AC or 96V DC rating.

3. Check Fault and Inrush Current: Verify the available fault current, 10kA breaking capacity, and compatibility of the C curve with normal startup demand.

4. Mount and Terminate: Install on DIN rail using conductors within the specified 18–3 AWG range and apply the listed 2.5 Nm terminal torque.

5. Inspect Before Energizing: Verify wiring, labeling, protective-device coordination, and code compliance before commissioning.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

🏭 Typical Uses for the 7A 2-pole Breaker

• Machine-control branches specified at 7A
• Dedicated equipment circuits with moderate inrush
• Control-transformer and power-supply branches
• Two-pole AC or DC circuits requiring precise 7A protection

📚 Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




Kacon K16-211-R 16 mm Momentary Push Button, Round, SPDT, Red $7.74
Macromatic COH50A6AD Over Current Sensing Relay, 5-50A, 0.15-7 Sec, 12V, 1 Sec Delay $84.58
Macromatic TD-81622-44 10 - 10230 Min Off Delay 120V Time Delay Relay $69.20
Kacon B30-21B-C65 65 mm Momentary Push Button, Blue, Half Guard $32.34
Mencom MIN-5FP-3-B 5 Pole, Female Straight, 8A, 3 Feet, MIN Size I Cordset $36.25
Sealcon CD36AA-CP PG 36 Dome .87" - 1.26" (22 - 32 mm) O.D. Cord Grip w/ Clamp $45.86
Macromatic TCF8E Over Temperature & Seal Leak Relay, 24V, 7A SPDT & SPNC $204.40
Sealcon CD11A5-BR Nickel Plated Brass PG 11 Dome 4 Hole .11" (2.8 mm) Insert Cord Grip $7.69
Macromatic CAH50A8BH Current Sensing Relay, 5-50A, 0.5-50 Sec, 24V, 5 Sec Delay $90.96