Home > Circuit Breakers >

IMO UB10D2032A Miniature Circuit Breaker, 32 A, D Curve, 2 Pole, Din Rail Mount


IMO UB10D2032A Miniature Circuit Breaker, 32 A, D Curve, 2 Pole, Din Rail Mount
IMO UB10D2032A Miniature Circuit Breaker, 32 A, D Curve, 2 Pole, Din Rail Mount
 
Alternative Views:


Price: $59.71
Note: Ships in 4-7 Business Days
MFG P/N: UB10D2032A
MFG: IMO Precision Controls
Weight (lbs): 0.55

Quantity in Stock :31


Availability:
In Stock
Product Code: UB10D2032A
Qty:

Description
 

IMO UB10D2032A 32A UL 489 Circuit Breaker, 2-pole, D Curve, 10kA

32A 2-pole D-curve miniature circuit breaker with thermo-magnetic protection, 10kA breaking capacity, DIN-rail mounting, and UL 489 approval.

Why Choose the IMO UB10D2032A Circuit Breaker?

The IMO Precision Controls UB10D2032A is a 32A 2-pole miniature circuit breaker for two-pole machinery and industrial equipment branches engineered for 32A protection and high startup current. It is rated for 480Y/277V AC or 96V DC and provides UL 489 branch-circuit protection in industrial control panels, machinery, and distribution equipment when applied within its electrical ratings.

Thermo-magnetic operation combines a thermal response for sustained overloads with rapid magnetic response during severe faults. The D curve delays magnetic tripping until a higher multiple of rated current, helping prevent nuisance trips on loads with brief, high startup current. A contact-position indicator provides a clear visual reference during inspection and troubleshooting.

⚡ 32A Rating

Protects a correctly sized 2-pole branch circuit rated for 32A

📉 D Trip Curve

10–20 × In magnetic range supports loads with high startup current

🛡️ 10kA Capacity

Provides 10kA short-circuit breaking capacity for suitable electrical systems

✅ UL 489 Approved

Approved for branch-circuit protection when selected and installed correctly

⚠️ Coordinate the 32A 2-pole Breaker with the Load

Confirm the 32A rating, 2-pole configuration, conductor current, 480Y/277V AC or 96V DC rating, available fault current, D trip curve, ambient conditions, and equipment requirements before installation. A D-curve breaker does not replace separate motor-overload protection when the equipment or applicable code requires it.

📋 32A D-Curve Magnetic Trip Range

The D-curve magnetic element operates at 10–20 times rated current. For the UB10D2032A, this corresponds to an instantaneous magnetic range of approximately 320–640A. The thermal element responds to sustained overloads. Confirm coordination with normal startup current and upstream or downstream protective devices.

Key Features & Benefits

  • 2-pole DIN-rail mounting configuration
  • Rated for 480Y/277V AC or 96V DC
  • Approximate magnetic trip range of 320–640A
  • Thermo-magnetic overload and short-circuit protection
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range with 2.5 Nm fastening torque
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 1.38" Width x 2.64" Depth (108mm x 35mm x 67mm)
Rated Current 32 Amp
Voltage Rating 480Y / 277V AC / 96V DC
Number of Poles 2
Tripping Curve D (10-20 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s² @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

📋 2-pole Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that conductor current and connected equipment are compatible with a 32A protective device.

2. Verify Pole and Voltage Requirements: Confirm that the circuit requires 2 poles and operates within the 480Y/277V AC or 96V DC rating.

3. Check Fault and Inrush Current: Verify the available fault current, 10kA breaking capacity, and compatibility of the D curve with normal startup demand.

4. Mount and Terminate: Install on DIN rail using conductors within the specified 18–3 AWG range and apply the listed 2.5 Nm terminal torque.

5. Inspect Before Energizing: Verify wiring, labeling, protective-device coordination, and code compliance before commissioning.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

🏭 Typical Uses for the 32A 2-pole D-Curve Breaker

• Two-pole machinery branch circuits
• Industrial transformer and conversion equipment
• High-inrush equipment feeders
• AC or DC circuits requiring 32A two-pole D-curve protection

📚 Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




Macromatic THR-13162-04 Encapsulated Time Delay Relay, Repeat Cycle OFF, 120V, 0.05-5 Sec $32.02
Fandis FF20GA115NE31 Type 3R Fan Filter 325mm x 325mm 115 Vac 434.1 CFM, Black $512.58
Mencom D-USB-BFBF-M25-PA USB Style B to Style B, M25 Plastic Port Adapter $28.42
Mencom MIN-5FP-3-R MIN Size I Cordset, 5 Pole, Female Right Angle, 8A, 3 Feet $49.27
Macromatic THR-12268-33 Encapsulated Time Delay Relay, Single Shot Falling Edge, 24V, 1-100 Min $28.28
Cembre 1900-M40 M40 .75" - 1.1" (19 - 28 mm) O.D. MAXIblock Cable Gland $3.66
Menics MT5C1AL-B 1 Stack 56mm Tower Light, Blue, 24V, Steady & Flashing $44.53
Sealcon ED16AR-BK Black PG 16 Elbow Dome .28" - .47" (7 - 12 mm) O.D. Cord Grip $15.49
Kacon K16-G2 Safety Guard for K16 Series Emergency Stop Switches $3.63