IMO UB10D100.5A Miniature Circuit Breaker, 0.5 A, D Curve, 1 Pole, Din Rail Mount


IMO UB10D100.5A Miniature Circuit Breaker, 0.5 A, D Curve, 1 Pole, Din Rail Mount
IMO UB10D100.5A Miniature Circuit Breaker, 0.5 A, D Curve, 1 Pole, Din Rail Mount
 
Alternative Views:


Price: $29.89
Note: Ships in 4-7 Business Days
MFG P/N: UB10D100.5A
MFG: IMO Precision Controls
Weight (lbs): 0.28

Quantity in Stock :75


Availability:
In Stock
Product Code: UB10D100.5A
Qty:

Description
 

IMO UB10D100.5A 0.5A UL 489 Circuit Breaker, 1-pole, D Curve, 10kA

0.5A 1-pole D-curve miniature circuit breaker with thermo-magnetic protection, 10kA breaking capacity, DIN-rail mounting, and UL 489 approval.

Why Choose the IMO UB10D100.5A Circuit Breaker?

The IMO Precision Controls UB10D100.5A is a 0.5A 1-pole miniature circuit breaker for low-current single-pole control, transformer, and equipment branches that experience high but brief inrush. It is rated for 277V AC or 48V DC and provides UL 489 branch-circuit protection in industrial control panels, machinery, and distribution equipment when applied within its electrical ratings.

Thermo-magnetic operation combines a thermal response for sustained overloads with rapid magnetic response during severe faults. The D curve delays magnetic tripping until a higher multiple of rated current, helping prevent nuisance trips on loads with brief, high startup current. A contact-position indicator provides a clear visual reference during inspection and troubleshooting.

⚡ 0.5 Amp Rating

Protects a correctly sized 1-pole branch circuit rated for 0.5A

📉 D Trip Curve

10–20 × In magnetic range supports loads with low startup current

🛡️ 10kA Capacity

Provides 10kA short-circuit breaking capacity for suitable electrical systems

✅ UL 489 Approved

Approved for branch-circuit protection when selected and installed correctly

⚠️ Coordinate the 0.5A 1-pole Breaker with the Load

Confirm the 0.5A rating, 1-pole configuration, conductor current, 277V AC or 48V DC rating, available fault current, D trip curve, ambient conditions, and equipment requirements before installation. A D-curve breaker does not replace separate motor-overload protection when the equipment or applicable code requires it.

📋 0.5A D-Curve Magnetic Trip Range

The D-curve magnetic element operates at 10–20 times rated current. For the UB10D100.5A, this corresponds to an instantaneous magnetic range of approximately 5–10A. The thermal element responds to sustained overloads. Confirm coordination with normal startup current and upstream or downstream protective devices.

Key Features & Benefits

  • 1-pole DIN-rail mounting configuration
  • Rated for 277V AC or 48V DC
  • Approximate magnetic trip range of 5–10A
  • Thermo-magnetic overload and short-circuit protection
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range with 2.5 Nm fastening torque
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 0.69" Width x 2.64" Depth (108mm x 17.5mm x 67mm)
Rated Current 0.5 Amp
Voltage Rating 277V AC / 48V DC
Number of Poles 1
Tripping Curve D (10-20 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s² @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

📋 1-pole Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that conductor current and connected equipment are compatible with a 0.5A protective device.

2. Verify Pole and Voltage Requirements: Confirm that the circuit requires 1 pole and operates within the 277V AC or 48V DC rating.

3. Check Fault and Inrush Current: Verify the available fault current, 10kA breaking capacity, and compatibility of the D curve with normal startup demand.

4. Mount and Terminate: Install on DIN rail using conductors within the specified 18–3 AWG range and apply the listed 2.5 Nm terminal torque.

5. Inspect Before Energizing: Verify wiring, labeling, protective-device coordination, and code compliance before commissioning.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

🏭 Typical Uses for the 0.5A 1-pole D-Curve Breaker

• Control-transformer primary circuits
• Inductive control components with high inrush
• Low-current industrial equipment branches
• AC or DC circuits requiring 0.5A D-curve protection

📚 Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




ILME CAP-24LS29 C-Type Surface Mount Housing, Size 104.27, Lever & Cover, PG 29 $63.17
ILME CAP-24CS29 C-Type Surface Mount Housing, Size 104.27, 4 Pegs & Cover, PG 29 $55.31
Macromatic PAP400 400V Plug-in Phase Monitor Relay $55.17
Mencom MDE45-4FR-RJ45-BM-2M Ethernet Receptacle, 4 Pole, Female, PG 9, 2 M $40.32
Kacon K16-180-R-12V 16 mm Red Pilot Lamp, Square, 12V DC LED $7.26
Mencom MDC-2MP-2M M12 Cordset, 2 Pole, Male Straight, 2 M $18.52
Light Efficient Design LED-7340-FC-G3 17W, 2G11 PLL LED Light, 3000-6500K, 120-277V $15.39
Saginaw SCE-10106SC Screw Cover Enclosure, 10.13" x 10" x 6" $107.42
Sealcon CD63M2-BK Black M63 Dome 6 Hole .47" (12 mm) Insert Cord Grip $37.08