LiteCycle SG-TB-10P15-GS 10-Circuit Gray Terminal Block Enclosure, 120V AC 15 Amps, IP65
Compact industrial terminal enclosure with an integrated 10-circuit, 20-termination block, 14-20 AWG conductor capacity, 120V AC rating, 15 Amps current rating, molded cable-entry knockouts, and IP65 protection when used with a properly rated cable gland.
Why Choose the LiteCycle SG-TB-10P15-GS Terminal Enclosure?
The LiteCycle SG-TB-10P15-GS is a gray industrial terminal enclosure with an integrated 10-circuit terminal block for organized control and power-distribution wiring. Its ABS construction, removable solid cover, and molded cable-entry knockouts make it practical for robotics, machinery, solar equipment, and control-system installations.
The enclosure is rated 120V AC at 15 Amps and accepts 14-20 AWG conductors through its integrated screw terminals. Each terminal has two screws so the two sides can be wired independently. The molded knockout design simplifies cable entry, and the enclosure can achieve IP 65 when installed with the appropriate cable gland and properly closed cover.
🔌 10 Integrated Circuits
Built-in terminal block provides 20 total termination points
⚡ 120V AC / 15 Amps
Rated for compact industrial control and connection applications
🧵 14-20 AWG Conductors
Screw-terminal capacity supports commonly used control-wire sizes
🛡️ IP65 Protection
Environmental protection depends on a properly rated cable gland and complete installation
⚠️ Maintain the IP65 Enclosure Rating
The listed protection rating applies when the enclosure is used with an IP65 cable gland and the cover is properly installed. Match the cable gland to the 13/16 in (20 mm) opening and 1/2 NPT thread size, confirm the cable outside diameter is within the gland range, and avoid damaging the molded knockout or cover seal.
⚙️ Industrial Control Wiring
The integrated terminal block keeps multiple conductors organized inside one compact enclosure. The solid cover is suited to machine and control-system installations where the terminal area should remain concealed during normal operation.
Key Features & Benefits
- Integrated 10-circuit terminal block with 20 total terminations
- Rated 120V AC, 60Hz, and 15 Amps
- Accepts 14-20 AWG conductors
- Two screws per terminal allow each side to be wired independently
- Gray ABS Plastic enclosure base
- Gray ABS plastic cover
- Molded knockout with 13/16 in (20 mm) entry opening and 1/2 NPT cable-entry size
- Ingress protection: IP 65 (with IP 65 or higher rated cable gland)
- Overall dimensions: 90mm Width X 100mm Length X 45mm Height (3.54" x 3.93" x 1.77")
- This model supports control connections, machine wiring, solar-equipment wiring, and wiring-trunking layouts that need a compact, enclosed termination point.
- Approvals: UL 508A:2005, CE
Technical Specifications
|
Dimensions
|
90mm Width X 100mm Length X 45mm Height (3.54" x 3.93" x 1.77")
|
|
Housing Color
|
Gray
|
|
Base Material
|
ABS Plastic
|
|
Cover Material
|
ABS Plastic
|
|
Connection Capacity
|
14-20 AWG
|
|
Wire Entry
|
Molded Knockout
|
|
Entry Opening
|
13/16 in (20 mm)
|
|
Maximum Size
|
1/2 NPT
|
|
Terminations
|
20
|
|
Circuits
|
10
|
|
Rated Voltage
|
120V AC
|
|
Rated Frequency
|
60Hz
|
|
Rated Current
|
15 Amps
|
|
Ingress Protection
|
IP 65 (with IP 65 or higher rated cable gland)
|
|
Approvals
|
UL 508A:2005, CE
|
📋 Terminal Enclosure Installation Overview
1. Select the Mounting Location: Confirm that the 90mm Width X 100mm Length X 45mm Height (3.54" x 3.93" x 1.77") enclosure fits the equipment layout and remains accessible for wiring and maintenance.
2. Prepare the Cable Entry: Open the molded knockout carefully and install a cable gland sized for the 13/16 in (20 mm) opening and 1/2 NPT entry.
3. Route the Conductors: Bring the cable into the enclosure without sharp bends or excessive strain, then verify that the gland grips and seals the cable properly.
4. Make the Terminal Connections: Strip and terminate 14-20 AWG conductors using the correct torque and wiring practices for the connected equipment.
5. Reinstall the Cover: Check conductor clearance, close the cover evenly, and inspect the cable-entry seal before energizing the circuit.
|
|
 |