Home > Electrical Enclosures > Terminal Enclosures > 20 Terminal Electrical Enclosures >

LiteCycle SG-TB-10P15-GC 10 Position, 20 Terminal Enclosure, Gray w/ Clear Cover, 3.54" x 3.93" x 1.77"


10 Position 20 Terminal Enclosure
LiteCycle SG-TB-10P15-GC 10 Position, 20 Terminal Enclosure, Gray w/ Clear Cover, 3.54" x 3.93" x 1.77"
 
Alternative Views:


Price: $17.35
Note: Delivery: 2-5 Business Days
MFG P/N: SG-TB-10P15-GC
MFG: LiteCycle
Weight (lbs): 0.4

Quantity in Stock :1


Availability:
In Stock
Product Code: SG-TB-10P15-GC
Qty:

Description
 

LiteCycle SG-TB-10P15-GC 10-Circuit Gray Terminal Block Enclosure with Clear Cover, 120V AC 15 Amps, IP65

Compact industrial terminal enclosure with an integrated 10-circuit, 20-termination block, 14-20 AWG conductor capacity, 120V AC rating, 15 Amps current rating, molded cable-entry knockouts, and IP65 protection when used with a properly rated cable gland.

Why Choose the LiteCycle SG-TB-10P15-GC Terminal Enclosure?

The LiteCycle SG-TB-10P15-GC is a gray electrical terminal enclosure with an integrated 10-circuit terminal block and a clear polycarbonate cover. The transparent cover allows visual inspection of the terminal area without immediately removing the enclosure cover, making it useful for industrial equipment and control wiring that may require routine checks.

The enclosure is rated 120V AC at 15 Amps and accepts 14-20 AWG conductors through its integrated screw terminals. Each terminal has two screws so the two sides can be wired independently. The molded knockout design simplifies cable entry, and the enclosure can achieve IP 65 when installed with the appropriate cable gland and properly closed cover.

🔌 10 Integrated Circuits

Built-in terminal block provides 20 total termination points

⚡ 120V AC / 15 Amps

Rated for compact industrial control and connection applications

🧵 14-20 AWG Conductors

Screw-terminal capacity supports commonly used control-wire sizes

👁️ Clear Cover

Polycarbonate cover allows convenient visual inspection of the terminal area

⚠️ Maintain the IP65 Enclosure Rating

The listed protection rating applies when the enclosure is used with an IP65 cable gland and the cover is properly installed. Match the cable gland to the 13/16 in (20mm) opening and 1/2 NPT thread size, confirm the cable outside diameter is within the gland range, and avoid damaging the molded knockout or cover seal.

👁️ Clear-Cover Wiring Inspection

The transparent polycarbonate cover provides a direct view of the terminal block and conductor area. This helps maintenance personnel confirm wire position and general condition before opening the enclosure for service.

Key Features & Benefits

  • Integrated 10-circuit terminal block with 20 total terminations
  • Rated 120V AC, 60Hz, and 15 Amps
  • Accepts 14-20 AWG conductors
  • Two screws per terminal allow each side to be wired independently
  • Gray ABS Plastic enclosure base
  • Clear polycarbonate cover
  • Molded knockout with 13/16 in (20mm) entry opening and 1/2 NPT cable-entry size
  • Ingress protection: IP 65 (when used with IP 65 cable gland)
  • Overall dimensions: 90mm Width X 100mm Length X 45 mm Height (3.54" x 3.93" x 1.77")
  • This model is well suited to control connections and wiring-trunking applications where visible terminal inspection can improve routine maintenance.
  • Approvals: UL 508A:2005, CE

Technical Specifications

Dimensions 90mm Width X 100mm Length X 45 mm Height (3.54" x 3.93" x 1.77")
Housing Color Gray
Cover Color Clear
Base Material ABS Plastic
Cover Material Polycarbonate
Connection Capacity 14-20 AWG
Wire Entry Molded Knockout
Entry Opening 13/16 in (20mm)
Thread Size 1/2 NPT
Terminations 20
Circuits 10
Rated Voltage 120V AC
Rated Frequency 60Hz
Rated Current 15 Amps
Ingress Protection IP 65 (when used with IP 65 cable gland)
Approvals UL 508A:2005, CE

📋 Terminal Enclosure Installation Overview

1. Select the Mounting Location: Confirm that the 90mm Width X 100mm Length X 45 mm Height (3.54" x 3.93" x 1.77") enclosure fits the equipment layout and remains accessible for wiring and maintenance.

2. Prepare the Cable Entry: Open the molded knockout carefully and install a cable gland sized for the 13/16 in (20mm) opening and 1/2 NPT entry.

3. Route the Conductors: Bring the cable into the enclosure without sharp bends or excessive strain, then verify that the gland grips and seals the cable properly.

4. Make the Terminal Connections: Strip and terminate 14-20 AWG conductors using the correct torque and wiring practices for the connected equipment.

5. Reinstall the Cover: Check conductor clearance, close the cover evenly, and inspect the cable-entry seal before energizing the circuit.


Related Products
Sealcon CD13NA-GY Gray 1/2" NPT Dome .24" - .47" (6 - 12 mm) O.D. Cable Gland Sealcon CD13NA-BK Black 1/2" NPT Dome .24" - .47" (6 - 12 mm) O.D. Strain Relief Fitting Sealcon CD13N2-BK Black 1/2" NPT Dome 6 Hole .12" (3 mm) Insert Cord Grip Sealcon CD13NR-BK Black Cord Grip, 1/2" NPT Dome .20" - .35" (5 - 9 mm) O.D.
Price: $1.61

Add
Price: $1.61

Add
Price: $3.96

Add
Price: $1.64

Add
NPT Size Nylon Strain Relief Fitting Standard Insert NPT Size Black Cable Gland CD13N2-BK Sealcon CD13NR-BK
Sealcon CD13NR-GY Gray Strain Relief Fitting, 1/2" NPT Dome .20" - .35" (5 - 9 mm) O.D. Sealcon CF13NA-GY Gray 1/2" NPT Flex .24" - .47" (6 - 12 mm) O.D. Strain Relief Fitting Sealcon CD13NR-BR Nickel Plated Brass 1/2" NPT Dome .20" - .35" (5 - 9 mm) O.D. Cord Grip Sealcon CD13NA-BR Nickel Plated Brass 1/2" NPT Dome .24" - 47" (6 - 12 mm) O.D. Cord Grip
Price: $1.64

Add
Price: $1.83

Add
Price: $9.40

Add
Price: $9.15

Add
CD13NR-GY Reduced Insert NPT Cord Grip CF13NA-GY Sealcon CD13NR-BR Sealcon CD13NA-BR Cable Gland
Sealcon CF13NA-BR Nickel Plated Brass 1/2" NPT Flex .24" - .47" (6 - 12 mm) O.D. Cord Grip Sealcon CD13N4-BR Nickel Plated Brass 1/2" NPT Dome 2 Hole .20" (5 mm) Insert Cord Grip
Price: $31.74

Add
Price: $14.39

Add
CF13NA-BR Cable Gland with 1/2" NPT Thread Sealcon CD13N4-BR