Home > Relays > Liquid Level Control Relays >

Macromatic LCP2A100F20 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 20 Sec Delay


Macromatic 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 20 Sec
Macromatic LCP2A100F20 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 20 Sec Delay
 
Alternative Views:


Price: $90.38
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: LCP2A100F20
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: LCP2A100F20
Qty:

Description
 

The Macromatic LCP2A100F20 is a single probe pump up (fill) liquid level control relay. This 8 Pin plug-in relay has an input voltage of 120V AC. It monitors the level of conductive liquid (such as tap water, chemical solution, seawater, etc.) in a tank. Sensitivity is adjustable within the set range. Used to monitor liquid levels in the tank for pumps, solenoids, or valves. Electroplating is prevented due to the DC voltage pulsed through the probe, while the fixed time delay prevents rapid cycling. Pilot duty rating. Note: LCP2B250F2 pictured for reference.

Specifications

  • Relay Function- Single Probe Pump Up Liquid Level Control Relay
  • Input Voltage- 120V AC
  • Output- 10A SPDT
  • Sensitivity Range- 4.7K to 100K Ohms
  • Voltage Tolerance- AC Operation: +10 / -15% of nominal at 50/60 Hz
  • Load- 2 VA
  • Probe Voltage- 5V DC Pulsed
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10A @ 240V AC / 7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Response Time- Pick Up: 20 Seconds, Drop Out: 500 Milliseconds
  • Dimensions- 2.4" Height x 1.7" Width x 3.2" Depth
  • Approvals- UL and CUL recognized, UL & CUL listed (with Socket)

When the level of conductive liquid goes below the probe, the fixed time delay starts and the LED flashes red. The relay energizes after the time delay and the LED is solid red. It stays this way until the liquid comes back up to the probe. The relay is then no longer energized and the LED is green.

Liquid Level Relay Connection Diagram

Macromatic LCP Series Installation Instructions

Macromatic Single Probe Pump Up Liquid Level Control Relay with 20 Second Delay LCP2A100F20


Related Products
Macromatic 70169-D 8 Pin Octal Socket
Price: $5.04

Add
Macromatic 70169-D 8 Pin Octal Socket



Mencom MIN-4FPX-6 MIN Size I Cordset, 4 Pole, Female Straight, 18 AWG, 6 Feet $38.89
Menics MT4B2AL-RY 2 Stack 45mm Tower Light, Red Yellow, 24V $28.86
Saginaw SCE-3PBI Push Button Enclosure, 3 Position, 22.5mm $74.37
Seifert 503501 KH503 500W 120V Control Cabinet Resistor Heater, 6.5" x 3.2" x 4.4" $192.83
Sealcon CD21AS-02 Gray PG 21 Dome .24" x .55" (6 x 14 mm) Romex Cord Grip $4.47
Menics ASGF-02-B 86mm Beacon Light, 24V, Blue, Steady/Flashing $31.58
Mencom DB09-3-16LS Panel Interface Connector, (3) DB9, 16LS housing $127.68
ILME CTF-24R CT Series Insert, Female, Size 104.27, 24 Pin, 16A, Screw Right $105.80
Mencom MIN-10MFPX-20 MIN Size III Cordset, 10 Pole, Male / Female Straight, 18 AWG, 20 Feet $153.02