Description
 

The Macromatic LCP1A100F20 is a single probe pump up liquid level control relay. This 8 Pin plug-in relay has an input voltage of 240V AC. It monitors the level of conductive liquid, (such as tap water, chemical solution, seawater, etc.) in a tank. Sensitivity is adjustable within the set range. Used to monitor liquid levels in the tank for pumps, solenoids, or valves. Electroplating is prevented due to the DC voltage pulsed through the probe. The fixed time delay prevents rapid cycling. Pilot duty rating. Note: LCP2B250F2 pictured for reference.

Specifications

  • Relay Function- Single Probe Pump Up Liquid Level Control Relay
  • Input Voltage- 240V AC
  • Output- 10A SPDT
  • Sensitivity Range- 4.7K to 100K Ohms
  • Voltage Tolerance- AC Operation: +10 / -15% of nominal at 50/60 Hz
  • Load- 2 VA
  • Probe Voltage- 5V DC Pulsed
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10A @ 240V AC / 7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Response Time- Pick Up: 20 Seconds, Drop Out: 500 Milliseconds
  • Dimensions- 2.4" Height x 1.7" Width x 3.2" Depth
  • Approvals- UL and CUL recognized, UL & CUL listed (with Socket)

When the level of conductive liquid goes below the probe, the fixed time delay starts and the LED flashes red. The relay energizes after the time delay and the LED is solid red. It stays this way until the liquid comes back up to the probe. The relay is no longer energized and the LED is green.

Liquid Level Relay Connection Diagram

Macromatic LCP Series Installation Instructions

LCP1A100F20 Macromatic Single Probe Liquid Level Control Relay with 20 Second Delay


Related Products
Macromatic 70169-D 8 Pin Octal Socket
Price: $5.04

Add
Macromatic 70169-D 8 Pin Octal Socket



Mencom MCG-11 PG 11 .197-.393" (5-10mm) Cable Gland $6.86
Seifert 1001303 Condensate Kit for 3030 & 3050 Thermoelectric Coolers $126.57
AerosUSA 1731020102 SPP 2G Insert for Cable Entry Frame, 1 Hole, 0.08-0.12", Set of 10 $22.41
Menics MS86-C Clear Lens for MS86 Beacon Lights $5.55
Sealcon CF13CA-BK Black PG 13 Flex .24" - .47" (6 - 12 mm) O.D. Elongated Cord Grip $2.19
Mencom CRSS-21 PG 21 .472-.748" (12.5-19mm) Cable Gland w/ Clamp $21.31
ILME CGMA-25 Male Crimp Pin, CG Series, Silver Plated, 100A, 4-3 AWG $7.81
Lumberg Automation 0985 YM57530 103/10M Ethernet M12 Cordset, Male Straight / RJ45, 4 Pin, 10 M, Shielded $88.39
Mueller BU-78K Kelvin Clip $73.82