Home > Circuit Breakers >

IMO UB10C100.5A Miniature Circuit Breaker, 0.5 A, C Curve, 1 Pole, Din Rail Mount


IMO UB10C100.5A Miniature Circuit Breaker, 0.5 A, C Curve, 1 Pole, Din Rail Mount
IMO UB10C100.5A Miniature Circuit Breaker, 0.5 A, C Curve, 1 Pole, Din Rail Mount
 
Alternative Views:


Price: $29.89
Note: Ships in 4-7 Business Days
MFG P/N: UB10C100.5A
MFG: IMO Precision Controls
Weight (lbs): 0.28

Quantity in Stock :34


Availability:
In Stock
Product Code: UB10C100.5A
Qty:

Description
 

IMO UB10C100.5A 0.5A UL 489 Miniature Circuit Breaker, 1-Pole, C Curve, 10kA

0.5A single-pole UL 489 miniature circuit breaker with C-curve thermo-magnetic protection, 10kA interrupting capacity, and DIN-rail mounting.

Why Choose the IMO UB10C100.5A Circuit Breaker?

The IMO Precision Controls UB10C100.5A is a 0.5A single-pole miniature circuit breaker for low-current instrumentation, monitoring, and control circuits where a 0.5A branch rating is specified. It provides branch-circuit protection at up to 277V AC or 48V DC and mounts on DIN rail for efficient integration into industrial control and distribution panels.

Thermo-magnetic operation combines delayed thermal response for overload protection with fast magnetic response during severe faults. The C-curve trip characteristic responds at 5–10 times rated current, making the breaker suitable for correctly engineered circuits with moderate inrush, while its contact-position indicator supports visual status checks.

⚡ 0.5A Rating

Protects a correctly sized single-pole branch circuit rated for 0.5A

📉 C Trip Curve

5–10 × In magnetic trip range accommodates moderate equipment inrush

🛡️ 10kA Capacity

Provides a 10kA short-circuit breaking capacity for suitable systems

✅ UL 489 Approved

Approved for branch-circuit protection when applied within its ratings

⚠️ Coordinate the Breaker with the Entire Circuit

Do not select a breaker from amperage alone. Verify the 0.5A rating against conductor current, equipment requirements, system voltage, available fault current, pole count, trip curve, ambient conditions, and applicable electrical codes before installation.

📋 How the C-Curve Trip Characteristic Works

The thermal element responds to sustained overloads, while the magnetic element trips rapidly during high fault current. For this 0.5A breaker, the C-curve instantaneous magnetic range is specified at 5–10 times rated current. Confirm coordination with load inrush and upstream/downstream protective devices.

Key Features & Benefits

  • Single-pole DIN-rail mounting design
  • C-curve trip characteristic with 5–10 × In magnetic response
  • Thermo-magnetic overload and short-circuit protection
  • 277V AC / 48V DC voltage rating
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range
  • 20,000 mechanical and 6,000 electrical operations
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 0.69" Width x 2.64" Depth (108mm x 17.5mm x 67mm)
Rated Current 0.5 Amp
Voltage Rating 277V AC / 48V DC
Number of Poles 1
Tripping Curve C (5-10 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s2 @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

📋 Circuit-Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that the circuit design and conductor current are compatible with a 0.5A protective device.

2. Verify System Ratings: Check voltage, frequency, available fault current, and required interrupting capacity.

3. Confirm Trip Behavior: Make sure the C curve is appropriate for the load’s normal startup or inrush current.

4. Install Correctly: Mount on DIN rail and follow the specified conductor range and 2.5 Nm terminal torque.

5. Test and Document: Verify operation, labeling, coordination, and compliance before energizing the protected circuit.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

🏭 Typical Uses for the 0.5A Breaker

• Low-current instrumentation branches
• Control circuits for monitoring and signaling equipment
• Small control-transformer or interface circuits
• Panel branches requiring a 0.5A UL 489 breaker

📚 Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide