Macromatic THR-14166-37 Encapsulated Time Delay Relay, On/Off Delay, 12V, 10-1000 Min


Macromatic THR-14166-37 Time Delay Relay
Macromatic THR-14166-37 Encapsulated Time Delay Relay, On/Off Delay, 12V, 10-1000 Min
 
Alternative Views:


Price: $32.70
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-14166-37
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-14166-37
Qty:

Description
 

The Macromatic THR-14166-37 is an on/off delay Time Delay Relay. This encapsulated relay has an input voltage of 12V DC. It has an adjustable time range of 10 to 1000 minutes. Time is adjusted by turning the blue dials at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- On/Off Delay
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 10 - 1000 Min
  • Input Voltage- 12V DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 40ms
  • Startup Time- 0.05 seconds
  • Maintain Function Time- 0.01 seconds
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With the On/Off Delay function, the T1 time delay starts when the control voltage is present and the trigger is introduced. The relay energizes after the time delay and stays energized for the duration of the T2 time delay. Afterward the relay is de-energized until another trigger is introduced. If the trigger is removed during T1, it stays de-energized and the time delay resets. If the trigger is re-introduced during T2, the relays stays energized and the time delay resets.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions




Coxreels 15355-18 Top Rewind 4 Way Roller Bracket, 18", 1275W-C Series $208.85
Saginaw SCE-L9126ELJWSS Stainless Steel Trough Junction Enclosure w/ Window, 9" x 12" x 6" $1,114.97
Meltric 63-88142 DSN100 100A, 600V, 2P+G Male Inlet $308.52
Sealcon M16 Rear Mount Panel Connector, Female, 10 Pin, w/ Flange, 5-9 mm $50.25
Macromatic THR-13162-37 Encapsulated Time Delay Relay, Repeat Cycle OFF, 120V, 10-1000 Min $32.02
Boxco BC-CTS-152513 Enclosure, 150x250x130, Clear Screw Cover, Polycarbonate $37.73
Menics E12R-10R IP 67 LED Indicator, 12mm, Round Head, 110VAC, Red $10.22
Mencom MDC-8MR-FLM16 M12 Receptacle, 8 Pole, Male, Front Mount, M16 $20.21
Macromatic CAH20A2BF Current Sensing Relay, 2-20A, 0.5-50 Sec, 120V, 3 Sec Delay $93.22