Power supply/signaling contact
|
1 plug-in terminal block, 5-pin / no signal contact
|
Network size - Length of cable
|
Twisted pair (TP)
|
0 - 100 m
|
Network size - Cascadibility
|
Line - / star topology
|
any
|
Power requirements
|
Operating voltage
|
24 V DC (-25% to +30%)
|
Current consumption at 24 V DC
|
max. 130 mA
|
Power consumption
|
max. 2,6 W at 24 V DC
|
Service
|
Diagnostics
|
LEDs (power, link status, data, error)
|
Redundancy
|
Redundancy functions
|
redundant 24 V power supply
|
Ambient conditions
|
Operating temperature
|
0 C to +60 C
|
Storage/transport temperature
|
-25 C to +70 C
|
Relative humidity (non-condensing)
|
10% to 95%
|
MTBF
|
116.3 years; MIL-HDBK 217F: Gb 25 C
|
Mechanical construction
|
Dimensions (W x H x D)
|
40 mm x 145 mm x 80 mm
|
Mounting
|
DIN Rail 35 mm
|
Weight
|
520 g
|
Protection class
|
IP 20
|
Mechanical stability
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration, 18 shocks
|
IEC 60068-2-6 vibration
|
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
|
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD)
|
4 kV contact discharge, 8 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 - 1000 MHz)
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 1 kV data line
|
EN 61000-4-5 surge voltage
|
power line: 1 kV (line/earth), 0.5 kV (line/line), 1 kV data line
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz - 80 MHz)
|
EMC emitted immunity
|
FCC CFR47 Part 15
|
FCC CFR47 Part 15 Class A
|
EN 55022
|
EN 55022 Class A
|
Approvals
|
Safety of industrial control equipment
|
cUL 508 (E175531)
|
Hazardous locations
|
ISA 12.12.01 Class 1 Div. 2
|
Scope of delivery and accessories
|
Scope of delivery
|
device, terminal block, operating manual
|
Accessories to order separately
|
rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame
|