Network size - Length of cable
|
Twisted Pair (TP) |
0-100 M
|
Power requirements
|
Operating voltage
|
Power supply via the backplane of the MSP switch
|
Power consumption
|
3W
|
Power output in BTU/hr
|
10 |
Service
|
Diagnostics
|
LEDs (power, mode, link/data)
|
Ambient conditions
|
Operating temperature
|
0 C to +60 C (32 F to 140 F)
|
Storage/transport temperature
|
-40 C to +85 C (-40 F to 185 F)
|
Relative humidity (non-condensing)
|
5% to 95%
|
Mechanical construction
|
Dimensions (W x H x D)
|
38 mm x 133 mm x 118 mm (1.5" x 5.22" x 4.64")
|
Mounting
|
Backplane
|
Weight
|
193 g
|
Protection class
|
IP 20 (Protected from objects 12.5 mm (0.5") in diameter or greater)
|
Mechanical stability
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration
|
IEC 60068-2-6 vibration
|
5 Hz - 8.4 Hz with 3.5 mm amplitude; 8.4 Hz-150 Hz with 1 g
|
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD)
|
4 kV contact discharge; 8 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 MHz-3000 MHz)
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line; 4 kV data line
|
EN 61000-4-5 surge voltage
|
power line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV (line/earth)
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz-80 MHz)
|
EMC emitted immunity
|
FCC CFR47 Part 15
|
FCC CFR47 Part 15 Class A
|
EN 55022
|
EN 55032 Class A
|
Approvals
|
Safety of industrial control equipment
|
EN 60950
|
Basis Standard
|
C-Tick EN61131
|
Transportation
|
NEMA TS2
|
Scope of delivery and accessories
|
Scope of delivery
|
module, general safety instructions
|