Sealcon CD21NS-03 3/4" NPT Flat Cable Cord Grip: Black Nylon
Dome-style strain relief fitting for .28" x .55" (7 x 14mm) flat cable, with Nylon 6/6 construction, elastomer seal, IP68 protection, and a 150 psig pressure rating.
Liquid-Tight Strain Relief for Flat Cable
The Sealcon CD21NS-03 is a black Nylon 6/6 cord grip designed to secure flat electrical cable at an enclosure, junction box, panel, or equipment entry. It uses a 3/4" NPT thread and a shaped .28" x .55" (7 x 14mm) sealing insert that matches compatible flat cable more closely than a standard round-cable gland.
Patented overlapping clamping splines apply concentric force around the cable while the recessed elastomer grommet helps protect the jacket from pullout, vibration, moisture, and environmental exposure. The CD21NS-03 is also identified as Hummel part number 1.587.3401.71 and is sold individually.
▭ Flat Cable Seal
Accommodates a .28" x .55" (7 x 14mm) rectangular cable profile.
🔩 3/4" NPT Thread
Fits compatible threaded entries or panel installations using the proper locknut.
💧 IP68 / NEMA 4X & 6
Supports demanding wet and washdown installations when correctly fitted and assembled.
📏 150 psig Rating
Rated for liquid-tight applications up to 150 psig (10 bar).
Key Features & Benefits
- Black Nylon 6/6 Body: Provides rugged, lightweight construction for industrial cable-entry applications.
- Elastomer Form Seal: Conforms around the cable profile to support a liquid-tight connection.
- Overlapping Clamping Splines: Apply even force around the cable to improve pullout resistance.
- Recessed Custom Grommet: Helps shield the cable jacket from mechanical damage and environmental exposure.
- Vibration-Resistant Dome: Helps maintain cable retention on machinery and moving equipment.
- IP69K Capability: Possible with an ideal cable fit and the separately sold O-ring correctly installed.
- Broad Temperature Range: Operates from -40°C to 100°C (-40°F to 212°F).
- Chemical Resistance: Resists salt water, acids, alkalis, gasoline, and oils under compatible service conditions.
- Halogen- and Phosphorus-Free: Supports applications with material-content requirements.
- UL 94 V-0 Flammability Rating: Uses flame-protected material for industrial equipment installations.
⚠️ Locknut & O-Ring Are Sold Separately
The CD21NS-03 cord grip is sold individually without a locknut or O-ring. A compatible locknut is required when the fitting cannot thread directly into the enclosure. Use the correct O-ring when the installation requires sealing at the enclosure wall.
IP69K performance is possible only with an ideal cable fit, correct assembly, and the appropriate O-ring. Verify the complete installation against the required enclosure and ingress-protection rating.
🏭 Typical Applications
The CD21NS-03 is intended for routing compatible flat cable into electrical enclosures, control panels, industrial machinery, junction boxes, pumps, motors, and outdoor equipment. Its corrosion-resistant polymer construction is useful in wet, washdown, marine, process, and general industrial environments where the cable fit and chemical exposure remain within the product requirements.
Technical Specifications
|
Brand
|
Sealcon
|
|
Model
|
CD21NS-03
|
|
Alternate Part Number
|
Hummel 1.587.3401.71
|
|
Product Type
|
Flat Cable Cord Grip / Strain Relief / Cable Gland
|
|
Color
|
Black
|
|
Body Material
|
Nylon 6/6
|
|
Seal Material
|
Elastomer
|
|
Thread Size
|
3/4" NPT
|
|
Cable Slot Size
|
.28" x .55" (7 x 14mm)
|
|
Through-Hole Diameter
|
1.05" (26.7mm)
|
|
Body Length
|
1.22" (31mm)
|
|
Thread Length
|
.55" (14mm)
|
|
Dome Wrench Flat
|
1.3" (33mm)
|
|
Body Wrench Flat
|
1.3" (33mm)
|
|
Operating Temperature
|
-40°C to 100°C (-40°F to 212°F)
|
|
Pressure Rating
|
150 psig (10 bar)
|
|
Ingress Protection
|
IP68; IP69K Possible with Ideal Fit & O-Ring
|
|
NEMA Rating
|
NEMA 4X & 6
|
|
Submersion Rating
|
Up to 300 ft
|
|
Flammability
|
UL 94 V-0
|
📋 Installation Overview
1. Verify Cable Fit: Confirm that the flat cable profile matches the .28" x .55" (7 x 14mm) sealing slot.
2. Confirm Entry Method: Use a compatible 3/4" NPT threaded opening and obtain the correct locknut, if needed.
3. Add the O-Ring if Required: Install the separately sold O-ring when the enclosure-wall seal or target rating requires it.
4. Route the Cable: Pass the flat cable through the gland without twisting, folding, or damaging the jacket.
5. Secure the Body: Tighten the cord-grip body using the wrench flats while protecting the enclosure threads and sealing surface.
6. Tighten the Dome: Compress the elastomer seal evenly around the cable without overtightening.
7. Inspect the Assembly: Confirm cable retention, gasket contact, enclosure sealing, and strain relief before placing equipment in service.
Follow applicable electrical, enclosure, and installation requirements. Final ingress protection depends on the complete assembled system.
📦 What's Included
Included:
• (1) Sealcon CD21NS-03 Flat Cable Cord Grip
Sold Separately:
• Compatible Locknut
• Compatible O-Ring
Cable & Installation Compatibility Reference
Environmental Resistance & Compliance
📄 Trademark Note
Trademark: Romex is a registered trademark of Southwire Company.
|
|
 |