Meltric DSN20 Switch-Rated Receptacle Selector: Match Voltage, Amperage & Pole Configuration

Switch-Rated Selector

Switch-Rated Receptacle Selector: Meltric DSN20 20A Guide

Looking for a switch-rated simplex receptacle? Every Meltric DSN20 is a single-outlet 20A switch-rated receptacle. Filter by voltage, pole configuration, and washdown rating to land on the exact part number for your circuit.

Live-person support during business hours Interactive selector
Switch-Rated DisconnectBreak load safely, no separate disconnect switch needed.
Arc-Flash SafeEnclosed contacts and dead-front design keep the operator clear of the arc.
Washdown ReadyType 4X with IP66/67 or IP69 bodies survive high-pressure hosedown.
100kA WithstandClose-and-withstand short-circuit rating for hard industrial branch circuits.
Quick answer

Pick a DSN20 receptacle by matching three things: circuit voltage, pole/neutral configuration, and washdown rating. All DSN20 parts are 20A, switch-rated for load disconnect, 100kA-rated, and take 14-12 AWG. Add the -K16 suffix when you need Type 4X, IP69 high-pressure washdown instead of standard IP66/67.

Find the Right Product

Answer these three and we'll narrow the DSN20 lineup to your part.

1. What is your circuit voltage?
2. How many poles plus neutral/ground do you land?
3. What washdown rating do you need?

All Options

All 14 variants share the same 20A rating, 14-12 AWG screw terminals, -40°F to 140°F range, 100kA rating, and 2.2" x 3.03" x 3.15" body. You're choosing voltage, pole/neutral layout, and enclosure rating.

Meltric 63-14075 DSN20 20A, 125V, 1P+N+G Female Receptacle

Meltric 63-14075 DSN20 20A, 125V, 1P+N+G Female Receptacle

Product Code: 63-14075
Best for: 120/125V single-phase tools in general wet areas (IP66/67).
View Current Price
View Product
Meltric 63-14125-K16 DSN20 20A, 120V, 1P+N+G Female Receptacle

Meltric 63-14125-K16 DSN20 20A, 120V, 1P+N+G Female Receptacle

Product Code: 63-14125-K16
Best for: 120V single-phase loads in IP69 high-pressure washdown zones.
View Current Price
View Product
Meltric 63-14045 DSN20 20A, 277V, 1P+N+G Female Receptacle

Meltric 63-14045 DSN20 20A, 277V, 1P+N+G Female Receptacle

Product Code: 63-14045
Best for: 277V single-phase lighting or line-to-neutral loads.
View Current Price
View Product
Meltric 63-14072 DSN20 20A, 250V, 2P+G Female Receptacle

Meltric 63-14072 DSN20 20A, 250V, 2P+G Female Receptacle

Product Code: 63-14072
Best for: 250V two-wire single-phase equipment disconnects.
View Current Price
View Product
Meltric 63-14122-K16 DSN20 20A, 208V, 2P+G Female Receptacle

Meltric 63-14122-K16 DSN20 20A, 208V, 2P+G Female Receptacle

Product Code: 63-14122-K16
Best for: 208V 2-pole loads (listed 1 hp) in washdown environments.
View Current Price
View Product
Meltric 63-14042 DSN20 20A, 480V, 2P+G Female Receptacle

Meltric 63-14042 DSN20 20A, 480V, 2P+G Female Receptacle

Product Code: 63-14042
Best for: 480V two-pole ungrounded loads and disconnects.
View Current Price
View Product
Meltric 63-14142 DSN20 20A, 600V, 2P+G Female Receptacle

Meltric 63-14142 DSN20 20A, 600V, 2P+G Female Receptacle

Product Code: 63-14142
Best for: 600V two-pole loads (listed 3 hp) needing IK08 impact rating.
View Current Price
View Product
Meltric 63-14073 DSN20 20A, 250V, 3P+G Female Receptacle

Meltric 63-14073 DSN20 20A, 250V, 3P+G Female Receptacle

Product Code: 63-14073
Best for: 250V three-phase motor circuits, three-wire.
View Current Price
View Product
Meltric 63-14123-K16 DSN20 20A, 208V, 3P+G Female Receptacle

Meltric 63-14123-K16 DSN20 20A, 208V, 3P+G Female Receptacle

Product Code: 63-14123-K16
Best for: 208V three-phase loads (listed 3 hp) in washdown.
View Current Price
View Product
Meltric 63-14043 DSN20 20A, 480V, 3P+G Female Receptacle

Meltric 63-14043 DSN20 20A, 480V, 3P+G Female Receptacle

Product Code: 63-14043
Best for: 480V three-phase motors up to listed 7.5 hp.
View Current Price
View Product
Meltric 63-14076 DSN20 20A, 125/250V, 2P+N+G Female Receptacle

Meltric 63-14076 DSN20 20A, 125/250V, 2P+N+G Female Receptacle

Product Code: 63-14076
Best for: 125/250V split-voltage loads needing a neutral.
View Current Price
View Product
Meltric 63-14126-K16 DSN20 20A, 120/208V, 2P+N+G Female Receptacle

Meltric 63-14126-K16 DSN20 20A, 120/208V, 2P+N+G Female Receptacle

Product Code: 63-14126-K16
Best for: 120/208V loads with neutral in washdown zones.
View Current Price
View Product
Meltric 63-14047 DSN20 20A, 277/480V, 3P+N+G Female Receptacle

Meltric 63-14047 DSN20 20A, 277/480V, 3P+N+G Female Receptacle

Product Code: 63-14047
Best for: 277/480V three-phase with neutral for controls.
View Current Price
View Product
Meltric 63-14127-K16 DSN20 20A, 120/208V, 3P+N+G Female Receptacle

Meltric 63-14127-K16 DSN20 20A, 120/208V, 3P+N+G Female Receptacle

Product Code: 63-14127-K16
Best for: 120/208V three-phase-plus-neutral in IP69 washdown.
View Current Price
View Product

Which One Should You Buy?

Find the row that matches your setup:

Your situationOur pickWhy
120V single-phase tool receptacle in a general wet plant area Meltric 63-14075 DSN20 20A, 125V, 1P+N+G Female Receptacle63-14075 125V 1P+N+G, IP66/67 (standard single-phase disconnect).
120V load in a daily hosedown food-processing zone Meltric 63-14125-K16 DSN20 20A, 120V, 1P+N+G Female Receptacle63-14125-K16 Same 1P+N+G rating with IP69 for high-pressure washdown.
480V three-phase motor up to 7.5 hp Meltric 63-14043 DSN20 20A, 480V, 3P+G Female Receptacle63-14043 3P+G, 480V, listed 7.5 hp switch-rated disconnect.
600V two-pole load in a high-abuse area Meltric 63-14142 DSN20 20A, 600V, 2P+G Female Receptacle63-14142 600V 2P+G, listed 3 hp, IK08 impact-rated body.
120/208V receptacle needing both phases and a neutral Meltric 63-14126-K16 DSN20 20A, 120/208V, 2P+N+G Female Receptacle63-14126-K16 2P+N+G dual voltage, IP69 washdown.
277/480V three-phase load with neutral for controls Meltric 63-14047 DSN20 20A, 277/480V, 3P+N+G Female Receptacle63-14047 3P+N+G dual voltage, IP66/67.
208V three-phase motor in washdown, up to 3 hp Meltric 63-14123-K16 DSN20 20A, 208V, 3P+G Female Receptacle63-14123-K16 3P+G 208V, listed 3 hp, IP69 rated.
277V lighting-circuit disconnect, single-phase Meltric 63-14045 DSN20 20A, 277V, 1P+N+G Female Receptacle63-14045 277V 1P+N+G; the only DSN20 277V single-phase receptacle.

How These Options Differ

Start with your circuit voltage and how many current-carrying poles you actually land. Single-phase line-to-neutral loads (120V/125V/277V) take a 1P+N+G unit like the 63-14125-K16, 63-14075, or 63-14045. Two-hot ungrounded loads (208V, 250V, 480V, 600V) use 2P+G: the 63-14122-K16, 63-14072, 63-14042, and 63-14142. Three-phase, three-wire motors use 3P+G (63-14123-K16, 63-14073, 63-14043). When the load needs both full phases and a neutral (120/208V, 125/250V, or 277/480V), pick the combined-voltage parts: 63-14076, 63-14126-K16, 63-14127-K16, or 63-14047. Then decide enclosure grade: standard parts are Type 4X, IP66/67; the -K16 suffix upgrades to Type 4X, IP69 for direct high-pressure, high-temperature washdown. Note that not all parts have a horsepower rating. The 63-14043 lists 7.5 hp and the 63-14142 (600V) lists 3 hp. Match the exact voltage stamp; do not substitute 250V for 277V or 480V for 600V, which voids the UL/CSA listing.

How a switch-rated (Decontactor) receptacle works

A standard receptacle is not rated to break load; pulling a plug under current draws an arc. The Meltric DSN20 is built as a switch-rated disconnect: its contacts open inside the housing before the plug fully separates, so the load is interrupted safely and the operator never sees the arc.

  • Butt-style contacts make and break under full 20A load
  • 100kA close-and-withstand short-circuit rating
  • Dead-front design and safety shutter cover the contacts before the plug detaches
  • Rated for branch-circuit and motor-circuit disconnect switching (AC only)

That means one device does the job of a receptacle plus a disconnect switch. It's why several DSN20 units carry horsepower ratings (up to 7.5 hp on the 480V 3P+G 63-14043) and can serve as the motor disconnect at the point of use.

How to match DSN20 voltage and pole configuration

Two independent choices drive the part number: voltage and polarity. Get both right and the rest of the DSN20 spec is identical across the line.

  • 1P+N+G: single-phase line-to-neutral (120V, 125V, 277V)
  • 2P+G: two hots, no neutral (208V, 250V, 480V, 600V)
  • 3P+G: three-phase, three-wire motors (208V, 250V, 480V)
  • 2P+N+G / 3P+N+G: when the load needs both full phases and a neutral (dual-voltage parts like 125/250V, 120/208V, 277/480V)

Count the current-carrying conductors your load actually lands. A three-phase motor with no neutral needs 3P+G, not 3P+N+G. A 120/208V panel feeding both single- and three-phase loads through the neutral needs a P+N+G part. Never buy on voltage alone: the 250V line has 1P, 2P, and 3P variants.

DSN20 vs DSN30 and DSN60: picking the amp version

This article discusses the 20A version. Size the receptacle to your overcurrent protective device and full-load current, not the other way around.

  • DSN20: 20A branch circuits, tools, small motors, control power
  • DSN30: 30A loads, larger single- and three-phase motors
  • DSN60: 60A feeders and heavier motor circuits

If your breaker is 20A, the DSN20 is correct and its 14-12 AWG terminals match your conductors. If you're on a 30A or 60A circuit, do not force larger conductors into a DSN20; move up to the DSN30 or DSN60 version, which accepts the appropriate wire range. Voltage and pole logic carries across all three versions, so once you know your voltage and polarity you can select the same configuration in the correct amp size.

Choosing between IP66/67 and IP69 (-K16) washdown

Every DSN20 is Type 4X: corrosion-resistant, watertight, UV- and chemical-resistant blue fiberglass-reinforced polyester. The enclosure grade differs by suffix.

  • IP66/67 (standard parts): protected against powerful water jets and temporary immersion
  • IP69 (-K16 parts): total dust ingress protection plus high-pressure, high-temperature water jets from any direction

For food, beverage, pharma, and sanitary lines that get direct high-pressure/high-temperature hosedown, specify the -K16 version: 63-14125-K16, 63-14122-K16, 63-14123-K16, 63-14126-K16, or 63-14127-K16. For general wet or outdoor industrial use, the standard IP66/67 parts are sufficient. The 600V 63-14142 also carries an IK08 impact rating for mechanical abuse. Both grades share the same footprint and terminals, so the choice is purely about the wash environment.

DSN20 configurations at a glance (all 20A, 14-12 AWG, 100kA, -40°F to 140°F)

PartVoltagePolarityHP (listed)Enclosure
63-14075125V1P+N+G—IP66/67
63-14125-K16120V1P+N+G0.75IP69
63-14045277V1P+N+G—IP66/67
63-14072250V2P+G—IP66/67
63-14122-K16208V2P+G1IP69
63-14042480V2P+G—IP66/67
63-14142600V2P+G3IP66/67, IK08
63-14073250V3P+G—IP66/67
63-14123-K16208V3P+G3IP69
63-14043480V3P+G7.5IP66/67
63-14076125/250V2P+N+G—IP66/67
63-14126-K16120/208V2P+N+G0.75/1IP69
63-14047277/480V3P+N+G—IP66/67
63-14127-K16120/208V3P+N+G0.75/3IP69

Common Mistakes (and the Fix)

✗ Buying on voltage alone and ignoring pole count
✓ The 250V line has 1P, 2P, and 3P versions. Confirm how many phases and whether you land a neutral before ordering.
✗ Substituting a 480V unit on a 600V circuit
✓ Match the exact voltage stamp; use the 600V 63-14142 for 600V loads. Over-voltaging voids the UL/CSA listing.
✗ Treating it like an ordinary receptacle
✓ It's switch-rated, you can break load with it, but install it per its disconnect application, not as a general convenience outlet.
✗ Specifying standard IP66/67 for direct high-pressure washdown
✓ Use the -K16 IP69 parts anywhere sanitary hosedown with high-temperature jets occurs.
✗ Forgetting the mating plug and housing
✓ Order the matching DSN20 plug and angle adapter or handle/housing in the same voltage and pole configuration to complete the connection.
✗ Forcing oversized conductors into a DSN20
✓ DSN20 accepts 14-12 AWG only; for 30A/60A circuits move up to the DSN30 or DSN60 frame.

Frequently Asked Questions

What does DSN20 mean on a Meltric receptacle?

DSN is Meltric's Decontactor switch-rated series and 20 is the amp rating, so every DSN20 is a 20A device. You then choose voltage and pole configuration. All DSN20 bodies here share the same 2.2" x 3.03" x 3.15" footprint and 14-12 AWG screw terminals.

Is a DSN20 a simplex receptacle?

Yes, it's a single-outlet (simplex) industrial receptacle, but with a critical difference: it's switch-rated for branch-circuit and motor-circuit disconnect switching. Unlike a standard simplex receptacle, you can make and break load at full current under a 100kA short-circuit rating without arc-flash exposure to the operator.

How is DSN20 different from DSN30 or DSN60?

The number is the amp rating: DSN20 = 20A, DSN30 = 30A, DSN60 = 60A. If your overcurrent device and load exceed 20A, step up to DSN30 or DSN60. Pole/neutral configuration and voltage selection follow the same logic across all three frames. This page covers the 20A frame only.

What does the -K16 suffix mean?

The -K16 parts (like 63-14125-K16 and 63-14123-K16) carry a Type 4X, IP69 rating, meaning total dust protection and resistance to high-pressure, high-temperature water jets from any direction. Non-K16 parts are Type 4X, IP66/67. Choose -K16 for direct sanitary washdown.

Can I use a 250V DSN20 on a 277V circuit?

No. Match the exact voltage stamp. A 250V unit (63-14072) is not rated for 277V; use the 277V part (63-14045). Likewise the 480V parts (63-14042/63-14043) are not a substitute for 600V (63-14142). Over-voltaging voids the UL/CSA listing and is a safety hazard.

Do I need the receptacle and the plug, or just this?

This article covers the female receptacles only. A complete Meltric connection also needs the mating DSN20 plug and, typically, an angle adapter or handle/housing. Match the plug's voltage and pole configuration to the receptacle you pick here.

What wire size do DSN20 receptacles accept?

All DSN20 variants take 14-12 AWG on screw terminals, rated -40°F to 140°F (-40°C to 60°C). That covers standard 20A branch-circuit conductors. Torque terminals to Meltric's published spec and confirm your conductor insulation temperature rating.

Can a DSN20 serve as a motor disconnect?

Yes. DSN20 units are rated for branch-circuit and motor-circuit disconnect switching, and the parts with a published horsepower rating can serve as the motor disconnect at the point of use. For example, the 63-14043 lists 7.5 hp at 480V. Confirm your motor's full-load current and HP fall within the specific part's listed rating.

Terms Worth Knowing

Switch-rated
Rated to make and break load current under full amperage. Functions as both receptacle and disconnect switch.
Decontactor
Meltric's brand term for its switch-rated plug/receptacle devices, including the DSN series.
P+N+G
Pole(s) plus neutral plus ground: used when the load needs a grounded neutral conductor.
100kA close & withstand
The device can safely close onto and withstand a 100,000-amp short circuit without failure.
Type 4X
NEMA enclosure rating for watertight, dust-tight, and corrosion-resistant indoor/outdoor use.
IP69
Ingress rating for complete dust protection and resistance to close-range high-pressure, high-temperature water jets.
Safety shutter
Internal cover that seals over live contacts before the plug fully detaches, preventing accidental contact.
Simplex receptacle
A single-outlet receptacle; the DSN20 is a switch-rated version that can break load, unlike a standard one.