Home > Relays > Time Delay Relays >

Macromatic THR-16161-04J Encapsulated Time Delay Relay, Delayed Interval, 240V, 0.05-5 Sec, Internal Jumper


Macromatic THR-16161-04J Time Delay Relay
Macromatic THR-16161-04J Encapsulated Time Delay Relay, Delayed Interval, 240V, 0.05-5 Sec, Internal Jumper
 
Alternative Views:


Price: $32.16
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-16161-04J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-16161-04J
Qty:

Description
 

The Macromatic THR-16161-04J is a delayed interval Time Delay Relay. This encapsulated relay has an input voltage of 240V AC. It has an adjustable time range of 0.05 to 5 sec. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Delayed Interval
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 0.05 - 5 sec
  • Input Voltage- 240V AC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50%
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.01 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With Delayed Interval, the OFF time delay starts along with the input voltage. After that, the ON time delay starts and the relay is energized for the duration of the time delay. When the ON time delay finishes, the relay de-energizes. The input voltage has to be re-introduced to restart the cycle.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic 240V Delayed Interval Time Delay Relay with Jumper THR-16161-04J




Deca A20F-33E02Q4Y 22 mm Momentary Selector Switch, 3 Position, 2NC, 24V LED, Yellow $19.94
Mencom MIN-6FPX-20-SS MIN Size I Cordset, 6 Pole, Female Straight, 18 AWG, 20 Feet, Stainless Steel Coupling $124.27
Saginaw SCE-16PBH Hinged Push Button Enclosure, 16 Position, 30.5mm $243.39
Mencom MIN-8MPX-20 MIN Size II Cordset, 8 Pole, Male Straight, 18 AWG, 20 Feet $97.73
Sealcon 1.089.1303.19 PG 13 / 13.5, M20, 1/2" NPT 2 Hole .2" (5 mm) Insert $2.16
Mencom MDC-4FR-M16-18 M12 Receptacle, 4 Pin Female, 4A, M16 Mounting Thread, 18 AWG, 12" $20.02
Saginaw SCE-1210CHNF Continuous Hinge Enclosure, 12.13" x 10" x 5" $115.03
Cembre 1900-M20 M20 .28" - .51" (7 - 13 mm) O.D. MAXIblock Cable Gland, White $0.72
Deca A20F-2E10Q4G 22 mm Maintained Selector Switch, 2 Position, 1NO, 24V LED, Green $16.62