Home > Relays > Time Delay Relays >

Macromatic THR-10962-34J Encapsulated Time Delay Relay, Flasher ON, 120V, 0.1-10 Hrs, Internal Jumper


Macromatic THR-10962-34J Time Delay Relay
Macromatic THR-10962-34J Flasher ON, 120V, 0.1-10 Hr Encapsulated Time Delay Relay, Internal Jumper


 
Alternative Views:


Price: $58.51
Note: Ships in 5-10 Business Days
MFG P/N: THR-10962-34J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-10962-34J
Qty:

Description
 

The Macromatic THR-10962-34J is a flasher ON Time Delay Relay. This encapsulated relay has an input voltage of 120V AC/DC. It has an adjustable time range of 0.1 to 10 hours. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Flasher ON
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 0.1 - 10 Hours
  • Input Voltage- 120V AC/DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.1 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

The Flasher ON function means that the time delay starts and the relay is energized along with the input voltage. When the time delay stops it de-energizes and it stays that way for another interval. After that it energizes again and the cycle repeats itself until the input voltage is taken out.