Home > Relays > Time Delay Relays >

Macromatic THR-10861-37 Encapsulated Time Delay Relay, Flasher OFF, 240V, 10-1000 Min

Macromatic THR-10861-37 Time Delay Relay
Macromatic THR-10861-37 Flasher OFF, 240V, 10-1000 Min Encapsulated Time Delay Relay


 
Alternative Views:


Price: $58.51
Note: Ships in 5-10 Business Days
MFG P/N: THR-10861-37
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-10861-37
Qty:

Description
 

The Macromatic THR-10861-37 is a flasher OFF Time Delay Relay. This encapsulated relay has an input voltage of 240V AC. It has an adjustable time range of 10 to 1000 minutes. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Flasher (OFF Time 1st)
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 10 - 1000 minutes
  • Input Voltage- 240V AC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 seconds
  • Maintain Function Time- 0.01 seconds
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

Macromatic THR Series Relay Installation Instructions

10-1000 Minute 240V Flasher OFF Time Delay Relay THR-10861-37

Additional Product Information

For the Flasher (OFF 1st) function, the time delay starts when the input voltage is introduced. The relay energizes after the time delay ends, and stays energized for another time delay interval. The cycle repeats until the input voltage is taken out.

Explanation of Macromatic Time Delay Relay Timing Functions