Macromatic Relays Monitor and Protect Your Equipment

Macromatic · Products for Automation

Macromatic relays
monitor and protect your equipment.

Select the right relay for motors, pumps, compressors and control panels. Choose from time delay, phase and voltage monitor, alternating, current sensing, specialty and general purpose relays.

Most models are American-made and carry a 5-year warranty. Over 1,800 Macromatic items are available to choose from.

Need help selecting? 800-966-2345 · Eastlake, Ohio
Macromatic time delay relay
Macromatic relays for industrial control and equipment protection.
Start with the job

What does your equipment need the relay to do?

Match the function first, then narrow by voltage, mounting style and timing range.

Quick reference

Macromatic relay types at a glance

Macromatic relay types, functions and typical uses
Relay typeDetects / doesKey specsTypical uses
Time delayDelay, flash, repeat or time out a function. Use the timing functions chart to compare functions and diagrams.12 timing functions; 0.01 sec to 10,230 hours; 12 to 240 V; encapsulated, plug-in or 1/16 DINMaterial handling, pumps, irrigation, generators, HVAC
Phase monitorPhase loss, reversal, unbalanceSingle or multi-fault models; 190 to 600 V ACWastewater, pumps, packaging, generators
Voltage monitorOver, under or out-of-band voltageSingle-phase; voltage band modelsPumps, packaging, irrigation, generators
AlternatingEqualize run time on 2 or 3 loadsSelector-switch and door-mount modelsWastewater, pumps, HVAC
Current sensingOver, under or either current fault0.5-5, 2-20 and 5-50 A; 0.15-7 sec and 0.5-50 sec trip delay; encapsulatedMaterial handling, pumps, packaging, generators
Percentage timerON time as a share of a cyclePanel mount; some remember timing after power lossIrrigation, heating and cooling, motors, chemical feed
Seal leak / temperatureLeaks and over-temperature in submersible pumpsDoor-mount models; connects to an audible alarmSubmersible pumps, lift stations
Intrinsically safeControl a load in hazardous locationsPlug-in or DIN-rail housingsRefineries, grain elevators, lift stations
General purposeSwitch loads in control circuitsIce-cube plug-in with LED indicator (8-pin, 11-pin or octal socket) or slim DIN-rail with socket attachedControl panels, motors, compressors
Liquid level controlMonitor the level of conductive liquid; pump up or pump down controlSingle and dual probe plug-in models; 24 V AC/DC, 110-120 V AC/DC or 240 V AC; 1 to 60 sec delay; 4.7K-100K and 1K-250K sensitivityPump control, tanks, water and wastewater
Featured models

Popular relays

Popular Macromatic models cover timing, phase monitoring, percentage timing, pump seal protection, general purpose switching and load alternation.

Macromatic TE-8812U multi-function time delay relay
Time delay · Multi-function

Macromatic TE-8812U Time Delay Relay

Compact 17.5 mm DIN-rail time delay relay with universal 12-240 V AC/DC input, 10 selectable timing functions and DPDT output contacts.

Function
Multi-function time delay
Voltage
12-240 V AC/DC
Timing range
0.1 second to 10 days
Macromatic PMP575 phase monitor relay
Phase monitor · 460-600 V

Macromatic PMP575 Phase Monitor Relay

Three-phase plug-in monitor for phase reversal, phase loss, phase unbalance, overvoltage and undervoltage in higher-voltage industrial systems.

Function
Three-phase monitoring
Voltage
460-600 V AC adjustable nominal range
Output
10A SPDT
Macromatic PTA1030S percentage timer
Percentage timer · Panel mount

Macromatic PTA1030S Percentage Timer

30-second percentage timer for applications that require adjustable ON time as a percentage of the total cycle, including irrigation, heating, cooling and chemical feed systems.

Function
Percentage timer
Voltage
240 V AC
Output
10A SPNO
Macromatic SFP120A250 pump seal failure relay
Seal leak · Single channel

Macromatic SFP120A250 Seal Leak Relay

Single-channel pump seal failure relay for monitoring moisture leakage in submersible pump seals, with adjustable sensitivity and LED status indication.

Function
Pump seal failure monitoring
Voltage
120 V AC
Sensitivity
1K to 250K ohms
Macromatic GSC024C general purpose slim DIN-rail relay
General purpose · Slim DIN rail

Macromatic GSC024C General Purpose Relay

6 mm slim DIN-rail relay for high-density control panels. The relay and socket are supplied as one unit with LED status indication and finger-safe protection.

Function
General purpose switching
Voltage
24 V AC/DC
Output
6A, 1 Form C
Macromatic ARP120A3R alternating relay
Alternating · Duplexor

Macromatic ARP120A3R Alternating Relay

Cross-wired duplexor alternating relay designed to balance operating time between two loads, with LED lead-load indication and a selector switch for manual lead selection.

Function
Alternating relay, DPDT cross wired
Voltage
120 V AC/DC
Output
10A DPDT cross wired

Check before you order: Verify voltage, timing range, contact rating, housing and socket on the product page. Specifications and stock are subject to change.

Selection checklist

Five questions before you choose

Relay selection checklist
QuestionWhy it matters
What is the control voltage?Listings span 12 V AC/DC to 575 V AC. Voltage must match or be within range if a range is specified.
Single-phase or 3-phase?Phase monitors protect 3-phase systems; voltage monitors protect single-phase.
What timing range is needed?Ranges run from 0.01 sec to 10,230 hours. Pick a range that leaves room on both ends.
How will it mount?Surface, DIN-rail or plug-in. Plug-in relays need a matching socket, often octal, which are usually sold separately.
What is the environment?Encapsulated housings suit harsh conditions. Hazardous locations call for intrinsically safe relays (Note that intrinsically safe relays still need to be mounted in a safe location).
Common questions

Macromatic relay FAQ

Click or tap to expand
What is a Macromatic relay?

Macromatic makes industrial control relays that monitor electrical loads, voltages, phase errors, and other machine functions. The line includes time delay, phase monitor, voltage monitor, alternating, current sensing, percentage timers, seal leak, and intrinsically safe relays, plus general purpose models.

Are Macromatic relays made in the USA?

Many are. American-made Macromatic relays are typically built to order and carry a 5-year warranty. Confirm origin and warranty before ordering.

How do I choose between a phase monitor and a voltage monitor relay?

Use a phase monitor on 3-phase equipment to catch phase loss, phase reversal and unbalance. Use a voltage monitor on single-phase systems to catch over or under voltage, or a voltage band relay to keep voltage inside a set range.

What mounting styles are available?

Surface mount, DIN-rail mount and plug-in, depending on the model. Most Macromatic plug-in relays use an octal socket. Sockets are typically sold separately and are linked on the product page to the corresponding relay.

Which Macromatic relay balances run time between two pumps?

An alternating relay. It equalizes run time across 2 or 3 loads, and some models add a selector switch to choose which load runs first or to alternate.

Major Electronix Corporation

Need help choosing a relay?

Send us the voltage, function and mounting style. We will help you identify the right Macromatic part.

Products for Automation, a division of Major Electronix Corporation · Eastlake, Ohio

Warranty and availability vary by model; confirm on each product page.