Macromatic CAH50A6AJ Current Sensing Relay, 5-50A, 0.15-7 Sec, 12V, 6 Sec Delay


Macromatic CAH50A6AJ Current Sensing Relay
Macromatic CAH50A6AJ 5-50A, 12V Current Sensing Relay, 6 Sec Delay


 
Alternative Views:


Price: $117.10
Note: Ships in 5-10 Business Days
MFG P/N: CAH50A6AJ
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CAH50A6AJ
Qty:

Description
 

The Macromatic CAH50A6AJ is a current sensing relay. This encapsulated relay has an input voltage of 12V DC. It is made to check for over or undercurrent faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 5-50A and a trip time delay of 0.15-7 seconds. There is a 6 second sensing time delay on startup. It has an integrated current transformer which provides greater access and sensitivity, as the wire can be looped around more than once. Ideal for use in harsher environments, due to the encapsulated housing. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Over/undercurrent
  • Current Monitor Range- 5-50 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 6 Seconds
  • Input Voltage- 12V DC
  • Output- 10 Amps SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-50A Turns; 300A Inrush for 10 Seconds
    Trip Point Hysteresis: -5% Overcurrent sensing +5% Undercurrent sensing
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

The relay starts checking for errors once the input voltage is applied and after the 6 second sensing start-up delay. For an overcurrent condition, the AC current goes above the set Fault Trip Current for longer than the adjusted time delay. The relay energizes after the pick-up time delay and remains in that state until the current goes under the reset level. If an undercurrent error occurs, the current goes below the set Fault Trip Current for longer than the adjusted time delay. Again, the relay energizes after the pick-up time delay and will de-energize once the current goes over the reset level. The user chooses whether the relay monitors over or under current errors using the selector switch. The CAH50A6AJ has an LED which is red to indicate when a fault has occurred. Has pilot duty rating. Example of common applications include process control, monitoring for locked rotor or load loss, or open heater or lamp.

Macromatic CAH Series Relay Installation Manual

Macromatic CAH50A6AJ Current Sensing Relay with 6 Second Startup Delay