Home > Relays > Current Sensing Relays >

Macromatic CAH05A6AG Current Sensing Relay, 0.5-5A, 12V, 0.15-7 Sec, 4 Sec Delay


Macromatic CAH05A6AG Current Sensing Relay
Macromatic CAH05A6AG Current Sensing Relay, 0.5-5A, 12V


 
Alternative Views:


Price: $117.10
Note: Ships in 5-10 Business Days
MFG P/N: CAH05A6AG
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CAH05A6AG
Qty:

Description
 

The Macromatic CAH05A6AG is a current sensing relay. This encapsulated relay has an input voltage of 12V DC. It monitors for over or undercurrent faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 0.5-5A and a trip time delay of 0.15-7 seconds. There is a 4 second sensing time delay on startup. The built in current transformer promotes better access and sensitivity, as the wire can be looped around more than once. The encapsulated housing is designed for use in harsher environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Over/undercurrent
  • Current Monitor Range- 0.5-5A
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 4 Second
  • Input Voltage- 12V DC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
    Trip Point Hysteresis: -5% Overcurrent sensing +5% Undercurrent sensing
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with 2 #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

With the selector switch, the user is able to choose whether the relay checks for over or under current conditions. The relay starts monitoring for possible faults once the input voltage is introduced. For an overcurrent situation, it occurs when the AC current goes over the set Fault Trip Current for longer than the adjusted time delay. The relay energizes after the time delay and stays energized until the current goes below the reset level. For an undercurrent fault, the current goes below the set Fault Trip Current for longer than the time delay. Again, the relay energizes after the time delay and will de-energize once the current goes above the reset level. The CAH05A6AG has an LED which glows red to indicate when a fault is found. Has pilot duty rating. It is commonly used in applications such as process control, checking for locked rotor or load loss, or open heater or lamp.

Macromatic CAH Series Relay Installation Manual

CAH05A6AG Macromatic 0.5-5A 12V DC Current Sensing Relay