Hirschmann GDMZRC21153160 Form A DIN 43650 PG11 Solenoid Valve Connector: 110-120V AC LED Indicator + MOV Suppression
Clear right-angle EN 175301-803 Form A connector with 18 mm contact spacing, 2 Poles + Ground, PG 11 (4.5 to 11 mm Cable OD) cable entry, screw with conductor protection, NBR Profile gasket, and IP65 protection.
Visible Power Status for Solenoid Valve and Actuator Wiring
The Hirschmann GDMZRC21153160 is a hardwired Form A DIN 43650 solenoid valve connector for hydraulic, pneumatic, and electromagnetic actuators. Its clear housing makes the integrated 110-120V AC LED easy to see, helping technicians confirm electrical status during startup, troubleshooting, and scheduled maintenance.
The 110-120V AC LED provides a visible power indication, while the MOV suppressor helps limit transient overvoltage at the source and load. The right-angle housing accepts cables through a PG 11 (4.5 to 11 mm Cable OD) entry, while the central M3 x 37 mm screw provides vibration-resistant locking. When properly assembled with the included NBR Profile gasket, the connector supports IP65 protection against dust and water jets.
💡 110-120V AC LED
Clear housing provides an at-a-glance indication when voltage is present.
⚡MOV Suppression
Integrated MOV helps suppress voltage transients in AC applications.
🔌 Form A, 18 mm
EN 175301-803 geometry with 2 poles + ground for compatible devices.
💧 IP65 Protection
Dust- and water-jet-resistant performance when correctly assembled with the gasket and center screw.
⚠️ Verify Circuit Voltage, Gasket, and Cable Diameter
Confirm that the connected load matches the 110-120V AC LED Indicator + MOV Suppression circuit and that the cable outside diameter fits the PG 11 (4.5 to 11 mm Cable OD) entry. This model includes a NBR Profile gasket; gasket material and profile affect sealing and application compatibility.
⚙️ Common Applications
Solenoid valves: Provide right-angle power connection and visible voltage status
Hydraulic and pneumatic actuators: Connect field wiring in automation equipment
Pressure and flow devices: Wire compatible sensors, switches, and flow indicators with Form A interfaces
Key Features & Benefits
- Combination Screw Terminal: Accepts flexible wire with ferrules and fork- or ring-style cable terminals
- Conductor Capacity: Accommodates conductors up to 16 AWG
- Central Fixing Screw: Provides secure, vibration-resistant locking
- Right-Angle Cable Entry: Directs the cable alongside the connected device
- Included Components: Connector, NBR Profile gasket, and center screw
Technical Specifications
|
Part Number
|
GDMZRC21153160
|
|
Brand
|
Hirschmann
|
|
Connector Standard
|
Form A DIN 43650 / EN 175301-803
|
|
Wiring Method
|
Hardwired
|
|
Circuit Type
|
110-120V AC LED Indicator + MOV Suppression
|
|
Housing Color
|
Clear
|
|
Contact Type
|
Screw with conductor protection
|
|
Contact Spacing
|
18 mm
|
|
Number of Poles
|
2 Poles + Ground
|
|
Cable Entry
|
PG 11 (4.5 to 11 mm Cable OD)
|
|
Maximum Conductor Size
|
16 AWG
|
|
Housing Dimensions
|
34.2 mm H x 53 mm L x 27.5 mm W
|
|
Fixing Screw
|
M3 x 37 mm
|
|
Gasket
|
NBR Profile
|
|
Operating Temperature
|
-40 F to +257 F
|
|
Protection Class
|
IP 65
|
|
Approvals
|
CE, RoHS
|
📋 Basic Wiring Overview
1. Verify compatibility: Confirm Form A geometry, 18 mm spacing, circuit voltage, polarity requirements, and cable diameter.
2. Prepare the cable: Route the cable through the PG 11 (4.5 to 11 mm Cable OD) entry and prepare conductors up to 16 AWG.
3. Terminate conductors: Secure the wires using the protected screw terminals and required grounding connection.
4. Fit the gasket: Position the included NBR Profile gasket evenly between the connector and mating device.
5. Secure and test: Tighten the M3 x 37 mm center screw, energize the circuit, and verify the LED and connected load.
🔎 Compatibility & Cross-Reference Notes
Possible cross-reference: MPM/Woodhead S18211TC441 (Housing height 27 mm, 8-10 mm cable entry) and CNE KA132V55T1 (Housing height 30.2 mm, 6-9 mm cable entry)
Cross-referenced products may have different housing heights or cable-entry ranges. Confirm electrical function, dimensions, gasket style, cable diameter, and mating compatibility before substitution.
|
|
 |
 |
 |
 |

|