Home > Circuit Breakers >

IMO UB10C1040A Miniature Circuit Breaker, 40 A, C Curve, 1 Pole, Din Rail Mount


IMO UB10C1040A Miniature Circuit Breaker, 40 A, C Curve, 1 Pole, Din Rail Mount
IMO UB10C1040A Miniature Circuit Breaker, 40 A, C Curve, 1 Pole, Din Rail Mount
 
Alternative Views:


Price: $29.89
Note: Ships in 4-7 Business Days
MFG P/N: UB10C1040A
MFG: IMO Precision Controls
Weight (lbs): 0.28

Quantity in Stock :33


Availability:
In Stock
Product Code: UB10C1040A
Qty:

Description
 

IMO UB10C1040A 40A UL 489 Miniature Circuit Breaker, 1-Pole, C Curve, 10kA

40A single-pole UL 489 miniature circuit breaker with C-curve thermo-magnetic protection, 10kA interrupting capacity, and DIN-rail mounting.

Why Choose the IMO UB10C1040A Circuit Breaker?

The IMO Precision Controls UB10C1040A is a 40A single-pole miniature circuit breaker for industrial machinery and distribution branches whose conductor, load, and upstream protection design calls for a 40A breaker. It provides branch-circuit protection at up to 277V AC or 48V DC and mounts on DIN rail for efficient integration into industrial control and distribution panels.

Thermo-magnetic operation combines delayed thermal response for overload protection with fast magnetic response during severe faults. The C-curve trip characteristic responds at 5–10 times rated current, making the breaker suitable for correctly engineered circuits with moderate inrush, while its contact-position indicator supports visual status checks.

⚡ 40A Rating

Protects a correctly sized single-pole branch circuit rated for 40A

📉 C Trip Curve

5–10 × In magnetic trip range accommodates moderate equipment inrush

🛡️ 10kA Capacity

Provides a 10kA short-circuit breaking capacity for suitable systems

✅ UL 489 Approved

Approved for branch-circuit protection when applied within its ratings

⚠️ Coordinate the Breaker with the Entire Circuit

Do not select a breaker from amperage alone. Verify the 40A rating against conductor current, equipment requirements, system voltage, available fault current, pole count, trip curve, ambient conditions, and applicable electrical codes before installation.

📋 How the C-Curve Trip Characteristic Works

The thermal element responds to sustained overloads, while the magnetic element trips rapidly during high fault current. For this 40A breaker, the C-curve instantaneous magnetic range is specified at 5–10 times rated current. Confirm coordination with load inrush and upstream/downstream protective devices.

Key Features & Benefits

  • Single-pole DIN-rail mounting design
  • Thermo-magnetic overload and short-circuit protection
  • 277V AC / 48V DC voltage rating
  • Contact-position indicator for visual status checks
  • 18–3 AWG conductor range
  • 20,000 mechanical and 6,000 electrical operations
  • UL 489, IEC 60947-2, IEC 60898-1, and RoHS compliance

Technical Specifications

Dimensions 4.25" Length x 0.69" Width x 2.64" Depth (108mm x 17.5mm x 67mm)
Rated Current 40 Amp
Voltage Rating 277V AC / 48V DC
Number of Poles 1
Tripping Curve C (5-10 In)
Calibration Temperature 104 F (40 C)
Operating Temperature -13 F to 131 F (-25 C to 55 C)
Rated Operational Frequency 50/60 Hz
Short Circuit Breaking Capacity 10kA
Lifespan 20,000 Operations (Mechanical), 6000 Operations (Electrical)
Vibration Resistance +/- 1mm @ 5-25 Hz; 50 m/s2 @ 25-150 Hz
Fastening Torque 2.5 Nm (22.2 lb/in)
Wire Range 18-3 AWG
NEMA Rating NEMA 1 (IP20 - Protection from objects 12.5 mm (0.5") in diameter or greater)
Approvals UL 489, IEC 60947-2 & IEC 60898-1, RoHS Compliant

📋 Circuit-Breaker Selection and Installation Overview

1. Calculate the Load: Confirm that the circuit design and conductor current are compatible with a 40A protective device.

2. Verify System Ratings: Check voltage, frequency, available fault current, and required interrupting capacity.

3. Confirm Trip Behavior: Make sure the C curve is appropriate for the load’s normal startup or inrush current.

4. Install Correctly: Mount on DIN rail and follow the specified conductor range and 2.5 Nm terminal torque.

5. Test and Document: Verify operation, labeling, coordination, and compliance before energizing the protected circuit.

Circuit-breaker selection and installation must be completed by qualified personnel in accordance with the equipment documentation and applicable electrical codes.

🏭 Typical Uses for the 40A Breaker

• Industrial machinery branch circuits
• Control-panel power-distribution sections
• Appropriately sized equipment feeders
• Branch circuits requiring a 40A UL 489 breaker

📚 Circuit Breaker Selection Resource

Compare IMO miniature circuit-breaker pole counts, amp ratings, trip curves, and series options before finalizing branch-circuit protection.

IMO Precision Controls Circuit Breaker Selection Guide




Hirschmann MAB 5100 5-Pin Panel Mount Circular Connector 930952517 $4.25
Sealcon NP-16-SS PG 16 Locking Nut $25.92
Menics ASGB-02-R 86mm Beacon Light, 24V, Red, Rotating w/ Alarm $48.58
Menics PME-01-R Red LED Module for PME Tower Lights, 12V $14.18
Mencom MAC-3FP-10M-R 1/2-20 Cordset, 3 Pole, Female Right Angle, 10 M $54.58
Macromatic CUH20A8AF Under Current Sensing Relay, 2-20A, 0.15-7 Sec, 24V, 3 Sec Delay $85.56
Macromatic TD-83122-44 10 - 10230 Min Repeat Cycle OFF 120V Time Delay Relay $72.85
Menics MS115T-FFF-R 115mm LED Beacon Light, 90-240V, Red, Flashing $137.21
Mencom MIN-9MR-1-18 MIN Size III Receptacle, 9 Pole, Male, 4A, 1/2"-NPT $32.78