Home > Relays > Current Sensing Relays >

Macromatic CUH05A6AD Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 12V, 1 Sec Delay


Macromatic CUH05A6AD Under Current Sensing Relay
Macromatic CUH05A6AD Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 12V, 1 Sec Delay
 
Alternative Views:


Price: $84.59
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: CUH05A6AD
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CUH05A6AD
Qty:

Description
 

The Macromatic CUH05A6AD is a current sensing relay. This encapsulated relay has an input voltage of 12V DC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 0.5-5A and a trip time delay of 0.15-7 seconds. There is a 1 second sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 0.5-5 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 1 Second
  • Input Voltage- 12V DC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, and after the 1 second start-up delay, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH05A6AD has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

Macromatic 12V DC Encapsulated Under Current Sensing Relay CUH05A6AD




Boxco BC-0816ST Steel Back Panel, for 80 x 160mm Enclosure $2.85
ILME CMSHM-10 CMSH Series Insert, Male, Size 104.27, 10 Pin, 16A $32.47
ILME CQF-05 CQ Series Insert, Female, Size 21.21, 5 Pin, 16A, Gray $6.68
Sealcon CD20MA-BK Black M20 Dome .24" - .47" (6 - 12 mm) O.D. Cord Grip $1.53
Mencom 207MPOT PG 7 Lock Nut, Nickel Plated Brass, w/ Cutting Edge $3.94
Menics MS56-C Clear Lens for MS56L Beacon Lights $4.55
Boxco BC-4060ST Steel Back Panel, for 400 x 600mm Enclosure $49.62
Macromatic ARP024A5R DPDT 24V Cross Wired Duplexor Alternating Relay (5-6 Control Voltage) $52.08
Macromatic PTA1002M Percentage Timer, 2 Min, 240V AC $165.28