Home > Relays > Time Delay Relays >

Macromatic TR-6652U 11 Pin Time Delay Relay, Delayed Interval, 24-240VAC


Macromatic TR-6652U Time Delay Relay
Macromatic TR-6652U 11 Pin Time Delay Relay, Delayed Interval, 24-240VAC
 
Alternative Views:


Price: $72.55
Note: Delivery: 2-5 Business Days
MFG P/N: TR-6652U
MFG: Macromatic
Weight (lbs): 0.3

Quantity in Stock :3


Availability:
In Stock
Product Code: TR-6652U
Qty:

Description
 

The Macromatic TR-6652U is a Triggered Delayed Interval Time Delay Relay. This programmable multi-range plug-in relay has a universal input voltage of 24-240V AC & 12-125V DC at 50/60Hz, with 10A DPDT output contacts. It has 16 built in time ranges, from 0.05 sec to 100 hours, using rotary switches. Adjustments within a certain time range can be made using the potentiometer switches. The TR-6652U uses an 11 pin 70170-D octal socket. This relay replaces TR-66521, TR-66522, TR-66526, & TR-66528. Note: Image is an approximation. Actual part may differ.

Timing Ranges

  • A: 0.05 - 0.5 Sec
  • B: 0.1 - 1 Sec
  • C: 0.5 - 5 Sec
  • D: 1 - 10 Sec
  • E: 3 - 30 Sec
  • F: 6 - 60 Sec
  • G: 0.2 - 2 Min
  • H: 0.5 - 5 Min
  • I: 1 - 10 Min
  • J: 3 - 30 Min
  • K: 6 - 60 Min
  • L: 0.2 - 2 Hr
  • M: 0.5 - 5 Hr
  • N: 1 - 10 Hr
  • O: 2.4 - 24 Hr
  • P: 10 - 100 Hr

Specifications

  • Function- Delayed Interval (Control Switch Trigger)
  • Timing Range- 0.05 Sec - 100 Hours
  • Input Voltage- 24-240V AC & 12-125V DC
  • Output- 10A DPDT
  • Voltage Tolerance- AC Operation: 20.4-264V at 50/60 Hz.
    DC Operation: 10.2-137.5V
  • Load- 3VA max.
  • Setting Accuracy- Maximum Setting: +5%, -0%
    Minimum Setting: +0%, -50%
  • Repeat Accuracy- Greater amount of +/- 0.1% or +/- 50ms
  • Reset Time- 0.04 Seconds
  • Start Up Time- 0.05 Sec
  • Maintain Function Time- 0.01 Sec
  • Operating Temperature- -28 C to 65 C (-18 F to 150 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- DPDT 10A @ 240V AC/30V DC,
    1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.)
    B300 & R300 (N.O.); AC15 & DC13
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Dimensions- 2.4" Height x 1.7" Width x 3.5" Depth
  • Approvals- UL & CUL recognized, CE, UL & CUL listed (with Socket)

This type of Delayed Interval uses a control switch trigger. The OFF time delay starts when the input voltage & trigger are introduced. After that, the ON time delay starts and the relay energizes for the duration of the time delay. When the ON time delay finishes, the relay de-energizes and the trigger has to be re-introduced to restart the cycle.

Macromatic TR-6 Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic TR-6652U Triggered Delayed Interval Time Delay Relay


Related Products
Macromatic 70170-D 11 Pin Octal Socket Macromatic 70166 Hold Down Spring
Price: $9.29

Add
Price: $1.59

Add
Macromatic 70170-D 11 Pin Octal Socket Macromatic Hold Down Spring



Macromatic THR-14166-34J Encapsulated Time Delay Relay, On/Off Delay, 12V, 0.1-10 Hr, Internal Jumper $32.72
Mencom MIN-3MP-12 MIN Size I Cordset, 3 Pole, Male Straight, 13A, 12 Feet $45.71
Macromatic CUH20A1BJ Under Current Sensing Relay, 2-20A, 0.5-50 Sec, 240V, 6 Sec Delay $89.03
Menics MS70LT-GF00-C 70mm LED Beacon Light, 12-24V, Clear, Flashing, Surface Mount $73.57
Mencom MIN-4FP-FW MIN Size I Plug, 4 Pole, Female Straight, 5-13 mm $24.62
Sealcon DUO22MA-BK M20 DUO PA .39" - .55" (10 - 14 mm) Conduit Fitting, Fits Size 14 $4.74
Cembre 1900-M25 M25 .39" - .67" (10 - 17 mm) O.D. MAXIblock Cable Gland, White $1.16
Menics H10F-24G LED Indicator, 10mm, Flat Head, 24VDC, Green $6.34
Meltric 31-1A426 DS20 Protective Inlet Cap $46.62