Home > Relays > Time Delay Relays >

Macromatic THR-16166-33J Encapsulated Time Delay Relay, Delayed Interval, 12V, 1-100 Min, Internal Jumper


Macromatic THR-16166-33J Time Delay Relay
Macromatic THR-16166-33J Encapsulated Time Delay Relay, Delayed Interval, 12V, 1-100 Min, Internal Jumper
 
Alternative Views:


Price: $31.64
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-16166-33J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-16166-33J
Qty:

Description
 

The Macromatic THR-16166-33J is a delayed interval Time Delay Relay. This encapsulated relay has an input voltage of 12V DC. It has an adjustable time range of 1 to 100 minutes. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Delayed Interval
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 1 - 100 Min
  • Input Voltage- 12V DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50%
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.01 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With Delayed Interval, the OFF time delay starts along with the input voltage. After that, the ON time delay starts and the relay is energized for the duration of the time delay. When the ON time delay finishes, the relay de-energizes. The input voltage has to be re-introduced to restart the cycle.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions




DuraChoice T5D90250 Bi-Metal Thermometer, 5" Dial, 9" Stem, 0-250 F $35.60
Mencom MCG-36R PG 36 .787-1.02" (20-26mm) Cable Gland $39.41
Seifert 3200305 24V 680 BTU Peltier Control Cabinet Thermoelectric Cooler, External $2,225.29
Boxco BC-CTS-101010 Enclosure, 100x100x100, Clear Screw Cover, Polycarbonate $17.44
AerosUSA 1731020114 SPP 14G Insert for Cable Entry Frame, 1 Hole, 0.55-0.59", Set of 10 $22.41
Meltric 37-68047 DS60 60A, 277/480V, 3P+N+G Metal Male Inlet $540.67
Mencom MIN-3FP-12 MIN Size I Cordset, 3 Pole, Female Straight, 13A, 12 Feet $48.58