Home > Relays > Liquid Level Control Relays >

Macromatic LCP1B100F4 240V Single Probe Liquid Level Relay, Pump Down, 4.7K to 100K, 4 Sec Delay


Macromatic 240V Single Probe Liquid Level Relay, Pump Down, 4.7K to 100K, 4 Sec
Macromatic LCP1B100F4 240V Single Probe Liquid Level Relay, Pump Down, 4.7K to 100K, 4 Sec Delay
 
Alternative Views:


Price: $93.62
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: LCP1B100F4
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: LCP1B100F4
Qty:

Description
 

The Macromatic LCP1B100F4 is a single probe pump down (drain) liquid level control relay. This 8 Pin plug-in relay has an input voltage of 240V AC. It monitors the level of conductive liquid (such as tap water, chemical solution, seawater, etc.) in a tank. Sensitivity is adjustable within the set range. Used to monitor liquid levels in the tank for pumps, solenoids, or valves. Electroplating is prevented due to the DC voltage pulsed through the probe, while the fixed time delay prevents rapid cycling. Pilot duty rating. Note: LCP2B250F2 pictured for reference.

Specifications

  • Relay Function- Single Probe Pump Down Liquid Level Control Relay
  • Input Voltage- 240V AC
  • Output- 10A SPDT
  • Sensitivity Range- 4.7K to 100K Ohms
  • Voltage Tolerance- AC Operation: +10 / -15% of nominal at 50/60 Hz
  • Load- 2 VA
  • Probe Voltage- 5V DC Pulsed
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10A @ 240V AC / 7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Response Time- Pick Up: 4 Seconds, Drop Out: 500 Milliseconds
  • Dimensions- 2.4" Height x 1.7" Width x 3.2" Depth
  • Approvals- UL and CUL recognized, UL & CUL listed (with Socket)

When the level of conductive liquid goes above the probe, the fixed time delay starts and the LED flashes red. The relay energizes after the time delay and the LED is solid red. It stays this way until the liquid drains below the level of the probe. The relay is then no longer energized and the LED is green.

Liquid Level Relay Connection Diagram

Macromatic LCP Series Installation Instructions

240V AC 4.7K to 100K Ohms Liquid Level Control Relay LCP1B100F4


Related Products
Macromatic 70169-D 8 Pin Octal Socket
Price: $5.04

Add
Macromatic 70169-D 8 Pin Octal Socket



DuraChoice PB404L-K02 Oil Filled Pressure Gauge, 4" Dial, 1/4" NPT, 0-2000 PSI $29.62
Z+F V30AE009062 Non-Insulated End Sleeve, 12 AWG, 0.35" Length $0.02
GardTec SC60-P10 60mm Plastic Fan Guard $0.42
Light Efficient Design LED-8033M30D-G7 35W Post Top Light, 3000K, 120/277V, Dimmable, Mogul Base $47.50
Light Efficient Design LED-8039E345D-A 18W Bollard LED Light, 3000K 4000K 5000K, 120/277V, Edison Base $38.75
Mencom MDC-5FPX-2M M12 Cordset, 5 Pole, Female Straight, 18 AWG, 2 M $23.62
Light Efficient Design LED-8089M345D-G4 80W Wall Pack Light, 3000K 4000K 5000K, 120/277V $133.35
Light Efficient Design LED-8035E40-A 60W Low Bay Light, 4000K, 120/277V $105.00