Home > Relays > Current Sensing Relays >

Macromatic CUH05A2AF Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 120V, 3 Sec Delay


Macromatic CUH05A2AF Under Current Sensing Relay
Macromatic CUH05A2AF Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 120V, 3 Sec Delay
 
Alternative Views:


Price: $87.80
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: CUH05A2AF
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CUH05A2AF
Qty:

Description
 

The Macromatic CUH05A2AF is a current sensing relay. This encapsulated relay has an input voltage of 120V AC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 0.5-5A and a trip time delay of 0.15-7 seconds. There is a 3 second sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 0.5-5 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 3 Seconds
  • Input Voltage- 120V AC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, and after the 3 second start-up delay, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH05A2AF has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

Macromatic 120V AC 0.5-5 Amp Under Current Sensing Relay CUH05A2AF




Sealcon CD20DA-FE M20 Dome .39" - .55" (10 - 14 mm) EMI/RFI Proof Elongated Cord Grip, Feed Through $31.26
ILME CDAM-16N CDA Series Insert, Male, Size 66.16, 16 Pin (17-32) $20.16
Menics M16P-03R LED Indicator, 16 mm, Protrusive Head, 3VDC, Red $7.92
Light Efficient Design LED-8030M40-MHBC 140W Utility Light, 4000K, For MH Ballast $154.05
MURR 7700-12041-1610100 M12 Cordset Male Straight, 5 Pole, 1 M $26.35
ILME CKA-03VAS C-Type Angled Metallic Hood, Size 21.21, PG 11, 2 Pegs $7.39
ILME MQLS-24IO32 Kit, 24 Pole Inserts, Spring Termination, Single Lever Base, Side Entry M32 Hood $115.58
Menics ASG-FF-G 86mm Beacon Light, 110/220V, Green, Rotating $41.29
Macromatic PAP240 240V Plug-in Phase Monitor Relay $55.17