Home > Relays > Current Sensing Relays >

Macromatic CUH05A1AD Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 240V, 1 Sec Delay


Macromatic CUH05A1AD Under Current Sensing Relay
Macromatic CUH05A1AD Under Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 240V, 1 Sec Delay
 
Alternative Views:


Price: $89.05
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: CUH05A1AD
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CUH05A1AD
Qty:

Description
 

The Macromatic CUH05A1AD is a current sensing relay. This encapsulated relay has an input voltage of 240V AC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 0.5-5A and a trip time delay of 0.15-7 seconds. There is a 1 second sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 0.5-5 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 1 Second
  • Input Voltage- 240V AC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, and after the 1 second start-up delay, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH05A1AD has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

Under Current Sensing Relay with 1 Second Start-up Delay CUH05A1AD




Menics M10P-24R LED Indicator, 10 mm, Protrusive Head, 24VDC, Red $5.54
DuraChoice PB403B-V00 Oil Filled Vacuum Gauge, 4" Dial, 3/8" NPT, -30HG-0 PSI, Back Mount $42.36
Mencom MINE-5MFPX-5M MIN Size I Cordset, 5 Pole, Male / Female, 18 AWG, 5 M $81.40
Menics H06F-03B LED Indicator, 6mm, Flat Head, 3VDC, Blue $5.22
Macromatic THR-16162-32 Encapsulated Time Delay Relay, Delayed Interval, 120V, 0.1-10 Min $32.02
DuraChoice PB403L-200 Oil Filled Pressure Gauge, 4" Dial, 3/8" NPT, 0-200 PSI $40.35
Boxco BC-1217P Plastic Back Panel, for 125 x 175mm Enclosure $1.43
Sealcon CD36A4-BK Black PG 36 Dome 2 Hole .59" (15 mm) Insert Cord Grip $20.80
Mencom MDCM-5MFP-5M M12 Cordset, 5 Pole, Male/Female Straight, 5 M, Shielded $57.60