Seifert 6105313 340 BTU 120V Peltier Thermoelectric Enclosure Cooler, IP66 Stainless Steel
Filter-free 340 BTU Seifert Peltier enclosure cooler with 120V AC power, IP66 stainless-steel housing, built-in thermostat, recessed mounting, and no compressor or refrigerant.
Why Choose the Seifert 6105313?
The Seifert 6105313 thermoelectric enclosure cooler uses Peltier technology to remove heat from electrical cabinets without a compressor or refrigerant. Filters not needed. Internal and external heat sinks transfer heat away from the cabinet, while the ambient fan assists heat dissipation outside the enclosure.
A corrosion-resistant AISI 304 stainless-steel housing, IP66 protection category, built-in thermostat, and recessed mounting make this 340 BTU cooler suitable for demanding indoor or outdoor control cabinet applications. It can be mounted vertically or horizontally to support different enclosure layouts.
❄️ 340 BTU Cooling
Rated cooling capacity at 95°F internal and 95°F ambient conditions
🔧 Filter-Free Design
No filters, compressor, or refrigerant are required
🛡️ IP66 Protection
Stainless-steel housing resists dust and powerful water jets
↔️ Flexible Mounting
Supports vertical or horizontal recessed installation
⚠️ Confirm Cutout, Orientation, and Electrical Requirements
Before ordering, verify the enclosure mounting opening, recessed depth, selected vertical or horizontal orientation, 120V AC 60 Hz supply, 2A time-delay fuse requirement, and clear airflow paths for both the cabinet and ambient air circuits.
📋 How the Peltier Cooling System Removes Heat
The thermoelectric system transfers heat from the cabinet side to the ambient side through internal and external heat sinks. Separate air circuits move cabinet air across the cold side and ambient air across the hot side, helping cool the enclosure without mixing the two air streams.
Key Features and Benefits
- 340 BTU thermoelectric cooling capacity at 95°F/95°F
- 120V AC, 60 Hz rated voltage
- Peltier cooling with no compressor or refrigerant
- Filter-free, low-maintenance operation
- Built-in thermostat for temperature control
- AISI 304 stainless-steel housing
- IP66 protection category
- Recessed enclosure mounting
- Vertical or horizontal mounting capability
- Separate ambient and cabinet air circuits
- CE and cURus approvals
- Two-year manufacturer warranty
Technical Specifications
| Brand |
Seifert |
| Model |
6105313 |
| Product Type |
Peltier Thermoelectric Enclosure Cooler |
| Cooling Capacity at 95°F/95°F |
340 BTU |
| Rated Voltage |
120V AC, 60 Hz |
| Nominal Current |
1.0A |
| Starting Current |
1.6A |
| Maximum Current |
1.2A |
| Power Consumption |
125W |
| Maximum Power Consumption |
139W |
| Fuse Rating |
2A Time-Delay (T) |
| Temperature Range |
-4°F to 149°F |
| Ambient Airflow |
75 / 125 CFM |
| Cabinet Airflow |
27 / 53 CFM |
| Housing Material |
AISI 304 Stainless Steel (V2A) |
| Mounting |
Recessed; Vertical or Horizontal |
| Dimensions |
11 in. H x 13.8 in. W x 6.5 in. D |
| Mounting Nut Torque |
4.5 Nm |
| Connection |
8-Pole Connector |
| Protection Category |
IP66 |
| Approvals |
CE, cURus |
| Warranty |
2-Year Manufacturer Warranty |
🔧 Installation and Setup Overview
1. Confirm Cooling Load: Verify that 340 BTU of cooling capacity at 95°F/95°F meets the enclosure heat-load requirement.
2. Plan the Cutout: Confirm the recessed mounting opening, 6.5-inch depth, and vertical or horizontal installation orientation.
3. Separate Air Paths: Keep both the cabinet-side and ambient-side airflow paths clear for effective heat transfer.
4. Complete Electrical Work: Connect the 120V AC, 60 Hz supply through the specified 8-pole connector and 2A time-delay fuse.
5. Check Temperature Control: Energize the unit and verify fan operation, thermostat control, and heat discharge on the ambient side.
Follow applicable electrical codes and the manufacturer’s installation instructions.
🏭 Typical Applications
Typical uses include outdoor electrical enclosures, industrial automation cabinets, instrumentation housings, telecommunications boxes, process-control panels, and other sealed cabinets that require filter-free cooling in dusty, wet, or demanding environments.
✅ Selection Notes
Choose the Seifert 6105313 when the enclosure needs 340 BTU of thermoelectric cooling, IP66 protection, stainless-steel construction, and low-maintenance operation without refrigerant or filter replacement.
|
|
 |