Macromatic THR-10962-31 Encapsulated Time Delay Relay, Flasher ON, 120V, 1-100 Sec


Macromatic THR-10962-31 Time Delay Relay
Macromatic THR-10962-31 Encapsulated Time Delay Relay, Flasher ON, 120V, 1-100 Sec
 
Alternative Views:


Price: $27.31
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-10962-31
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-10962-31
Qty:

Description
 

The Macromatic THR-10962-31 is a flasher ON Time Delay Relay. This encapsulated relay has an input voltage of 120V AC/DC. It has an adjustable time range of 1 to 100 seconds. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Flasher (ON Time 1st)
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 1 - 100 seconds
  • Input Voltage- 120V AC/DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 seconds
  • Maintain Function Time- 0.01 seconds
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

The Flasher ON function means that the time delay starts and the relay is energized along with the input voltage. When the time delay stops it de-energizes and it stays that way for another interval. After that it energizes again and the cycle repeats itself until the input voltage is taken out.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic 120V 1-100 Second Flasher ON Time Delay Relay THR-10962-31




Macromatic LCP8A100F15 24V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 15 Sec Delay $98.75
Sealcon CD40MR-BK Black M40 Dome .79" - 1.02" (20 - 26 mm) O.D. Cord Grip $16.24
DuraChoice PS254B-100 Oil Filled Pressure Gauge, 2-1/2" Dial, 1/4" NPT, 0-100 PSI, Back Mount $30.26
Seifert 871505201 Industrial Control Cabinet Air Conditioner, 5120 BTU, 230V $2,989.49
Menics PWEC-1FF-G 1 Stack LED Tower Light, Green, Steady, 90-240V $124.13
ILME MHO-16L32 C-Type Metallic Hood, Size 77.27, M32, 2 Pegs, Side Entry $21.42
Lumberg Automation RKMWV 3-593/5 M, Female Right Angle, 3 Pin, 5 M, M8 Molded Cable $17.43
Deca CPE10N Screw Clamp DIN Rail Ground Terminal Block, 6-16 AWG $4.71
Meltric 63-64162 DSN60 60A, 208V, 2P+G Female Receptacle $496.59