Home > Relays > Time Delay Relays >

Macromatic THR-16562-35 Encapsulated Time Delay Relay, Delayed Interval, 120V, 1-100 Hr


Macromatic THR-16562-35 Time Delay Relay
Macromatic THR-16562-35 Encapsulated Time Delay Relay, Delayed Interval, 120V, 1-100 Hr
 
Alternative Views:


Price: $32.91
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-16562-35
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-16562-35
Qty:

Description
 

The Macromatic THR-16562-35 is a triggered delayed interval Time Delay Relay. This encapsulated relay has an input voltage of 120V AC/DC. It has an adjustable time range of 1 to 100 hours. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Triggered Delayed Interval
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 1 - 100 Hrs
  • Input Voltage- 120V AC/DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 40ms
  • Startup Time- 0.05 seconds
  • Maintain Function Time- 0.01 seconds
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With Delayed Interval, the relay can accept a trigger after the input voltage is introduced. Once the trigger is introduced, the (t1) time delay starts. After that, the (t2) time delay starts and the relay is energized for the duration of the time delay. When the (t2) time delay finishes, the relay de-energizes. The trigger then needs to be re-applied for the cycle to start again.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions




Menics H10F-10W LED Indicator, 10mm, Flat Head, 110VAC, White $6.34
Seifert 871505201 Industrial Control Cabinet Air Conditioner, 5120 BTU, 230V $2,989.49
Seifert 400711 3 Meter Power Cable for LED Cabinet Light $16.24
Mencom MCVP-19MFP-1M M23 Cordset, 19 Pole, Male / Female, 1 m $211.95
Sealcon CD13N6-BK Black 1/2" NPT Dome 2 Hole .20" (5.2 mm) Insert Cord Grip $3.30
Lumberg Automation RSWUF 19-242/5M M23 Cordset, Male Right Angle, 19 Pin, 5 M $145.87
Kacon KSC-5030ZDHF Three Phase Solid State Relay w/ Fan, 24V DC Input, 90-480V AC Load, 30A $281.74
Mueller BU-60HS-2 Steel Alligator Clip w/ Red Handle & Screw $1.06
Mencom M40-0X0 M40 & 1-1/4" NPT Solid Insert $3.65