Home > Relays > Time Delay Relays >

Macromatic THR-10562-33J Encapsulated Time Delay Relay, Interval On, 120V, 1-100 Min, Internal Jumper


Macromatic THR-10562-33J Time Delay Relay
Macromatic THR-10562-33J Encapsulated Time Delay Relay, Interval On, 120V, 1-100 Min, Internal Jumper
 
Alternative Views:


Price: $27.34
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-10562-33J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-10562-33J
Qty:

Description
 

The Macromatic THR-10562-33J is an interval on Time Delay Relay. This encapsulated relay has an input voltage of 120V AC/DC. It has an adjustable time range of 1 to 100 min. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Interval On
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 1 - 100 min
  • Input Voltage- 120V AC/DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +/-2% or 50ms, whichever is greater
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.01 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

With the Interval On function, the time delay starts and the relay energizes along with the introduction of the input voltage. The relay de-energizes after the time delay ends. In order to re-energize the relay and re-start the time delay, the voltage must be removed & re-implemented.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic 120V Interval On 1-100 Minute Time Delay Relay with Jumper THR-10562-33J




Boxco BC-CTF-506025 Dual Door Enclosure, 530x630x255, Polycarbonate $445.89
Lumberg Automation RSCW 5/9 M12 Connector, 5 Pin, Male Right Angle, PG 9, Set of 5 $63.16
Sealcon EF09NA-BK Black 3/8" NPT Elbow Flex .16" - .31" (4 - 8 mm) O.D. Cord Grip $9.35
Mencom KADP-24-17 Cable Entry Plate, 17 5-9.2mm Entries $78.40
Z+F V30AE000082 Black Polypropylene Insulated End Sleeve, 16 AWG, 0.55" Length $0.02
Kacon KSR5040ZD Single Phase Solid State Relay w/ Alarm, 24V DC Input, 90-480V AC Load, 40A $79.02
MURR 7000-29441-0000000 Din 43650 Form A for Pressure Switch, 5-10mm, 24 V LED $40.85
Mencom MCVP-19FP-20M M23 Cordset, 19 Pole, Female, 1/10 A, 20 M $436.32
Menics ASGB-FF-Y 86mm Beacon Light, 110-220V, Yellow, Rotating w/ Alarm $53.43