Home > Relays > Time Delay Relays >

Macromatic THR-13166-04J Encapsulated Time Delay Relay, Repeat Cycle OFF, 12V, 0.05-5 Sec, Internal Jumper


Macromatic THR-13166-04J Time Delay Relay
Macromatic THR-13166-04J Encapsulated Time Delay Relay, Repeat Cycle OFF, 12V, 0.05-5 Sec, Internal Jumper
 
Alternative Views:


Price: $31.64
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: THR-13166-04J
MFG: Macromatic
Weight (lbs): 0.5



Availability:
In Stock
Product Code: THR-13166-04J
Qty:

Description
 

The Macromatic THR-13166-04J is a repeat cycle OFF Time Delay Relay. This encapsulated relay has an input voltage of 12V DC. It has an adjustable time range of 0.05 to 5 sec. Time is adjusted by turning the blue dial at the top. The encasement of the unit is made for use under harsh conditions. The design is microprocessor-based to provide better functionality, and is perfect for high volume OEM applications. The internal jumper connected to pin 2 provides easier wiring. Note: Image is for reference, actual part may differ

Specifications

  • Relay Function- Repeat Cycle OFF
  • Mounting Style- Surface Mount with #8 or #10 Screw
  • Termination- 0.25" Male Quick Connect Terminals
  • Relay Timing Range- 0.05 - 5 sec
  • Input Voltage- 12V DC
  • Output- 10 Amps SPDT
  • Voltage Tolerance- AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal voltage
  • Load- Max. 2VA
  • Setting Accuracy- Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50%
  • Repeat Accuracy- The greater amount of +/- 0.1% or +/- 0.04 Sec
  • Reset Time- 100ms
  • Startup Time- 0.05 sec
  • Maintain Function Time- 0.01 sec
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -45 C to 85 C (-49 F to 185 F);
  • Output Contacts- 10A @ 240VAC / 7A @ 28VDC SPDT, 1/4 hp @ 120VAC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Overall Dimensions- 2" Height x 2" Width x 1.14" Depth
  • Approvals- C UR US, CE

The Repeat Cycle OFF function means that once the input voltage is introduced, the OFF time delay starts. The relay energizes after this time delay, and stays energized during the ON time delay. After the ON time delay the relay de-energizes and the cycle repeats itself until the input voltage is taken out.

Macromatic THR Series Relay Installation Instructions

Explanation of Macromatic Time Delay Relay Timing Functions

Macromatic 12V Repeat Cycle Off Time Delay Relay with Jumper THR-13166-04J




Sealcon CD21CR-BE PG 21 Dome .35" - .63" (9 - 16 mm) EMI/RFI Proof Elongated Cord Grip $29.79
DuraChoice PB254L-300 Oil Filled Pressure Gauge, 2-1/2" Dial, 1/4" NPT, 0-300 PSI $10.50
ILME CHI-10C C-Type Bulkhead Mount Housing, Size 57.27, 4 Pegs $16.88
Menics M12P-24G LED Indicator, 12 mm, Protrusive Head, 24V DC, Green $5.11
Macromatic COH05A2AF Over Current Sensing Relay, 0.5-5A, 0.15-7 Sec, 120V, 3 Sec Delay $87.80
Mueller BU-190700153 Yellow Vinyl Insulated Ring Terminal, Stud Size 3/8", 12-10 AWG $0.21
DuraChoice PA158L-V30 Dry Utility Vacuum Gauge, 1-1/2" Dial, 1/8" NPT, -30HG-30 PSI $5.61
Mencom MDC-4MR-PG11 M12 Receptacle, 4 Pole, Male Straight, 4A, PG 11 $14.16
ILME CAO-10L29 C-Type Metallic Hood, Size 57.27, PG 29, 2 Pegs, Side Entry $25.37