DIN 43650 Connector Black Form B Comparison
Connector Comparison Guide
DIN 43650 Form B Connector Characteristics ComparisonCompare Hirschmann and HTP hardwired DIN 43650 / EN 175301-803 Form B connectors with 11 mm contact spacing, a PG 9 cable entry, and a black housing. Use the specifications below to match specification such as conductor size, cable diameter, approval requirements, and more before placing an order.
11 mm
Contact spacing
PG 9
Cable entry
250 V / 16 A
Rated electrical capacity
Screw Termination
Field-wireable
Choose Hirschmann when...Your installation calls for a UL-listed connector, support for conductors up to 16 AWG or a cable outside diameter between 4.5 and 7 mm. Choose HTP when...You need a slightly shorter 30 mm housing, an IP67 protection rating or compatibility with cable outside diameters from 4 to 6 mm. DIN 43650 Form B SpecificationsScroll horizontally on smaller screens to view the complete DIN Form B comparison table.
What These DIN Form B Specifications MeanCable FitMatch the cable outside diameter to the connector's sealing range. Hirschmann accepts a slightly wider maximum diameter, while HTP starts at a smaller 4 mm diameter. Environmental ProtectionIP65 protects against dust and water jets. IP67 adds protection against temporary water immersion when the connector is correctly assembled with compatible sealing components. Installation CompatibilityContact spacing, base dimensions, and cable range should all be checked. A matching Form B profile alone does not guarantee compatibility with every valve or device. Common Applications for Form B DIN ConnectorsHardwired DIN 43650 Form B connectors provide a removable electrical connection at compact industrial devices. They are frequently paired with solenoid-operated pneumatic or hydraulic valves, where the screw terminals simplify field wiring and the center screw holds the connector securely against vibration. The same format may also be used on compatible pressure switches, sensors, and other control components when the pin layout and cable entries match. Form B Connector Selection Checklist
1. Confirm the format:
Form B with 11 mm contact spacing.
2. Measure the cable:
Check conductor gauge and outside diameter.
3. Check the environment:
Select the required IP protection level.
4. Verify approvals:
Confirm UL and application requirements. Specifications shown are intended for comparison. Confirm the current product data and specifications on the product page before final selection. |