Sealcon CD25MP-BK M25 Black Nylon Dome Cord Grip with Solid Insert
M25 × 1.5 metric cable gland with a vibration-resistant dome, Nylon 6/6 body and IP65/NEMA 4X environmental protection.
Secure Cable Entry for Demanding Industrial Environments
The Sealcon CD25MP-BK metric nylon cord grip provides a secure cable-entry point for electrical enclosures, control panels, machinery and industrial equipment. Its M25 × 1.5 metric thread and rugged Nylon 6/6 construction make it suitable for applications exposed to vibration, moisture, salt water, oils and many common industrial chemicals.
The self-locking ACME thread in the dome compresses the overlapping internal splines evenly around the cable. This design helps maintain the environmental seal while providing strain relief and pull-out protection that reduces stress on internal wiring and termination points. The fitting is also identified as Hummel 1.597.2599.51 and uses Hummel insert 1.089.2199.19.
💧 IP65 / NEMA 4X
Protects properly fitted cable entries against dust, water and demanding outdoor or washdown conditions
📏 M25 × 1.5 Thread
Metric-threaded design for compatible control panels, junction boxes, enclosures and industrial equipment
🔒 Vibration-Resistant Dome
Self-locking ACME thread helps maintain consistent compression and cable retention under vibration
🛡️ Nylon 6/6 Body
Durable black nylon construction resists corrosion, salt water, acids, alkalis, gasoline and oils
Key Features & Benefits
- Reliable Strain Relief: Helps prevent cable movement from transferring force to internal terminals, splices and connected equipment
- Overlapping Compression Splines: Apply even pressure around the cable and help prevent the sealing insert from being pulled out of the fitting
- IP68 Potential: An IP68/NEMA 6 rating may be achieved under ideal installation and cable-fit conditions
- Chemical Resistance: Resists salt water, acids, alkalis, gasoline and oils for dependable service in harsh environments
- Flame-Protected Material: Nylon construction is flame protected to UL 94 requirements
- Halogen- and Phosphorus-Free: Suitable for installations with defined material-compliance requirements
- Solid Insert Configuration: Designed as a dome cord grip with no preformed cable holes for custom drilling
- Black Finish: Provides a clean appearance that coordinates with black enclosures, cables and industrial equipment
⚠️ Locking Nut and O-Ring Sold Separately
The Sealcon CD25MP-BK cord grip is sold individually. A compatible locking nut and O-ring are not included and must be ordered separately when required by the installation. Confirm the panel thread, mounting method and environmental sealing requirements before ordering.
📐 Cable Fit Determines the Final Protection Rating
Correct cable-to-insert sizing is essential for strain relief and environmental sealing. For IP65/NEMA 4X performance, the cable diameter should be at least 80% of the applicable sealing opening, and the difference between the cable diameter and opening should not exceed 0.04" (1 mm). IP68/NEMA 6 protection may be possible when the cable, insert and fitting produce an ideal seal.
Technical Specifications
| Manufacturer |
Sealcon |
| Part Number |
CD25MP-BK |
| Hummel Cross Reference |
1.597.2599.51 |
| Hummel Insert |
1.089.2199.19 |
| Product Type |
Metric nylon dome cord grip / cable gland / strain relief fitting |
| Thread Size |
M25 × 1.5 |
| Through-Hole Diameter |
0.98" (25 mm) |
| Body Length |
1.22" (31 mm) |
| Thread Length |
0.43" (11 mm) |
| Dome Wrench Flat |
1.3" (33 mm) |
| Body Wrench Flat |
1.3" (33 mm) |
| Number of Holes |
Not applicable: solid insert |
| Hole Diameter |
Not applicable: solid insert |
| Body Material |
Nylon 6/6 |
| Seal Material |
Elastomer |
| Color |
Black |
| Protection Rating |
IP65 / NEMA 4X |
| Potential Rating |
IP68 / NEMA 6 with an ideal cable fit |
| Flame Protection |
UL 94 |
| Quantity |
Sold individually |
🔧 Installation Guidelines
Before Installation:
1. Confirm the Thread: Verify that the enclosure or equipment accepts an M25 × 1.5 fitting
2. Check Cable Fit: Match the cable diameter to the sealing insert before installation
3. Prepare the Entry: Ensure the mounting surface and cable are clean and free from damage
4. Install the Body: Thread the fitting into the enclosure or secure it with a compatible locking nut
5. Insert the Cable: Route the cable through the fitting without twisting or damaging its jacket
6. Tighten the Dome: Tighten evenly so the internal splines compress the seal around the cable
7. Inspect the Seal: Confirm that the cable is securely retained and the fitting is properly seated
🏭 Common Applications
The Sealcon CD25MP-BK M25 cable gland can be used to route and secure cable entering:
• Industrial control panels
• Electrical enclosures
• Junction boxes
• Motors and machinery
• Factory automation equipment
• Outdoor electrical equipment
• Marine and coastal equipment
• Installations exposed to oils or industrial chemicals
Application & Selection Reference
|
|
 |