Macromatic TR-6 Time Delay Relay Cross Reference
Macromatic replacement guide
Macromatic TR-6 Time Delay Relay Cross Reference
Match a Macromatic TR-6 relay to selected Eaton Electrical, Rockwell Automation, and Schneider Electric timers, then verify the timing function, wiring and load requirements before installation.
24–240V AC
Universal AC input range
12–125V DC
Universal DC input range
16 ranges
Adjustable from 0.05 seconds to 100 hours
Which Macromatic TR-6 relay do I need?
Use TR-6022U for on-delay timing, TR-6162U for off-delay timing and TR-6312U for repeat-cycle timing that begins with the OFF period. The universal-voltage design and 16 timing ranges can consolidate multiple fixed-voltage or limited-range timer models.
⏱️
On Delay
Output contacts transfer after power is applied and the selected delay expires.
⏹️
Off Delay
Output remains energized for the selected delay after the control signal is removed.
🔁
Repeat Cycle — OFF First
Alternates adjustable OFF and ON periods continuously, beginning with OFF time.
Cross-Reference by Manufacturer
Use your browser’s “Find in page” feature to locate a complete competitor part number quickly. Click or tap a Macromatic model number to view the replacement relay.
Eaton Electrical
4 cross-reference numbers
Cross-reference option for the Eaton TMR5N on-delay catalog numbers below.
TMR5N05120TMR5N08120TMR5N0524TMR5N0824
Rockwell Automation / Allen-Bradley
140 cross-reference numbers
Replacement selection for the 700-HT12 on-delay timer numbers shown below.
View 20 Rockwell 700-HT12 part numbers
700-HT12AU12700-HT12BU12700-HT12CU12700-HT12DU12700-HT12EU12700-HT12AU24700-HT12BU24700-HT12CU24700-HT12DU24700-HT12EU24700-HT12AU120700-HT12BU120700-HT12CU120700-HT12DU120700-HT12EU120700-HT12AA2700-HT12BA2700-HT12CA2700-HT12DA2700-HT12EA2
Replacement selection for the 700-HT22 off-delay timer numbers shown below.
View 20 Rockwell 700-HT22 part numbers
700-HT22AU12700-HT22BU12700-HT22CU12700-HT22DU12700-HT22EU12700-HT22AU24700-HT22BU24700-HT22CU24700-HT22DU24700-HT22EU24700-HT22AU120700-HT22BU120700-HT22CU120700-HT22DU120700-HT22EU120700-HT22AA2700-HT22BA2700-HT22CA2700-HT22DA2700-HT22EA2
Replacement selection for 700-HV32 repeat-cycle timers. This Macromatic function begins with the OFF period.
View 100 Rockwell 700-HV32 part numbers
Rockwell suffix U12 — 25 catalog numbers
700-HV32AAU12700-HV32ABU12700-HV32ACU12700-HV32ADU12700-HV32AEU12700-HV32BAU12700-HV32BBU12700-HV32BCU12700-HV32BDU12700-HV32BEU12700-HV32CAU12700-HV32CBU12700-HV32CCU12700-HV32CDU12700-HV32CEU12700-HV32DAU12700-HV32DBU12700-HV32DCU12700-HV32DDU12700-HV32DEU12700-HV32EAU12700-HV32EBU12700-HV32ECU12700-HV32EDU12700-HV32EEU12
Rockwell suffix U24 — 25 catalog numbers
700-HV32AAU24700-HV32ABU24700-HV32ACU24700-HV32ADU24700-HV32AEU24700-HV32BAU24700-HV32BBU24700-HV32BCU24700-HV32BDU24700-HV32BEU24700-HV32CAU24700-HV32CBU24700-HV32CCU24700-HV32CDU24700-HV32CEU24700-HV32DAU24700-HV32DBU24700-HV32DCU24700-HV32DDU24700-HV32DEU24700-HV32EAU24700-HV32EBU24700-HV32ECU24700-HV32EDU24700-HV32EEU24
Rockwell suffix U120 — 25 catalog numbers
700-HV32AAU120700-HV32ABU120700-HV32ACU120700-HV32ADU120700-HV32AEU120700-HV32BAU120700-HV32BBU120700-HV32BCU120700-HV32BDU120700-HV32BEU120700-HV32CAU120700-HV32CBU120700-HV32CCU120700-HV32CDU120700-HV32CEU120700-HV32DAU120700-HV32DBU120700-HV32DCU120700-HV32DDU120700-HV32DEU120700-HV32EAU120700-HV32EBU120700-HV32ECU120700-HV32EDU120700-HV32EEU120
Rockwell suffix A2 — 25 catalog numbers
700-HV32AAA2700-HV32ABA2700-HV32ACA2700-HV32ADA2700-HV32AEA2700-HV32BAA2700-HV32BBA2700-HV32BCA2700-HV32BDA2700-HV32BEA2700-HV32CAA2700-HV32CBA2700-HV32CCA2700-HV32CDA2700-HV32CEA2700-HV32DAA2700-HV32DBA2700-HV32DCA2700-HV32DDA2700-HV32DEA2700-HV32EAA2700-HV32EBA2700-HV32ECA2700-HV32EDA2700-HV32EEA2
Schneider Electric / Square D
45 cross-reference numbers
Cross-reference option for Schneider Electric 9050JCK1-series on-delay timers.
9050JCK11V209050JCK12V209050JCK13V209050JCK14V209050JCK15V209050JCK16V209050JCK17V209050JCK18V209050JCK19V20
Cross-reference option for Schneider Electric 9050JCK2-series off-delay timers.
9050JCK21V209050JCK22V209050JCK23V209050JCK24V209050JCK25V209050JCK26V209050JCK27V209050JCK28V209050JCK29V20
Cross-reference option for Schneider Electric 9050JCK5-series repeat-cycle timers.
View 27 Schneider 9050JCK5 part numbers
9050JCK51V209050JCK52V209050JCK53V209050JCK54V209050JCK55V209050JCK56V209050JCK57V209050JCK58V209050JCK59V209050JCK51V369050JCK52V369050JCK53V369050JCK54V369050JCK55V369050JCK56V369050JCK57V369050JCK58V369050JCK59V369050JCK51V149050JCK52V149050JCK53V149050JCK54V149050JCK55V149050JCK56V149050JCK57V149050JCK58V149050JCK59V14
✅ Replacement Checklist
- Match the timing function first.
- Confirm the available control voltage.
- Check socket, pin layout and terminal wiring.
- Verify contact configuration and load rating.
- Set the required timing range and adjustment.
⚠️ Before You Replace a Timer
A cross reference identifies a likely functional replacement, but it does not replace an application review. Confirm the wiring diagram, trigger behavior, socket compatibility, contact load and environmental requirements before energizing the circuit.
Macromatic TR-6 Cross-Reference FAQ (Click for Answer)
Can one TR-6 relay replace several timer models?
Yes. The universal AC/DC input and 16 selectable timing ranges allow one correctly selected TR-6 function to cover many voltage and time-range variants. Electrical and mechanical compatibility must still be verified.
What is the difference between TR-6022U, TR-6162U and TR-6312U?
TR-6022U provides on-delay timing, TR-6162U provides off-delay timing and TR-6312U provides repeat-cycle operation beginning with the OFF period.
Does a listed cross reference guarantee a drop-in replacement?
No. Review the Macromatic product specifications and wiring diagram on the product page for the exact model. Socket arrangement, trigger method, contact load and application conditions can affect compatibility.
Need help confirming a replacement? Email [email protected] with the existing manufacturer part number, control voltage, timing function and wiring information.
|