JORC 2662 24V AC 3/8" NPT OPTIMUM Timer-Controlled Condensate Drain
JORC 2662 24V AC 3/8" NPT OPTIMUM Timer-Controlled Condensate Drain
24V AC timer-controlled condensate drain with 3/8" NPT inlet and outlet connections, 0–230 PSI (0–16 bar) pressure rating, brass valve housing, and a serviceable direct-acting solenoid valve.
✅ Designed For: Air compressors, refrigerated air dryers, and compressed-air systems with high condensate flow
The JORC 2662 is configured for
24V AC power, 3/8" NPT connections, and operating pressures up to 0–230 PSI (0–16 bar). Confirm the control voltage, port size, and pressure range before ordering because OPTIMUM timer drains are available in multiple electrical and connection configurations.
Automatic Condensate Drain Control for Compressed-Air Equipment
The JORC 2662 24V AC 3/8" NPT OPTIMUM Timer-Controlled Condensate Drain uses an adjustable electronic timer and a serviceable 2/2-way, direct-acting solenoid valve to discharge condensate from compressed-air equipment. It operates on 24V AC, uses 3/8" NPT connections, and is rated for 0–230 PSI (0–16 bar). The brass valve housing, LED cycle indication, TEST function, and NEMA 4 / IP65 protection support dependable operation in industrial compressed-air applications.
Adjustable ON and OFF cycles let the drain be matched to condensate volume and operating conditions. The timer range is 0.5–10 seconds ON / 0.5–45 minutes OFF, and the 4.5 mm (0.177 in.) valve opening supports controlled discharge. The valve is designed for compressor systems of any size.
⚡ 24V AC Control Power
Match the drain to the available control voltage before wiring or replacement
🔩 3/8" NPT Ports
Matching NPT inlet and outlet connections simplify integration into the condensate line
📈 0–230 PSI (0–16 bar)
Pressure rating supports the specified compressed-air operating range
⏱️ Adjustable Cycle Timing
0.5–10 seconds ON / 0.5–45 minutes OFF timer range for application-specific draining
Key Features and Benefits
- Adjustable Timer: ON/OFF cycle range of 0.5–10 seconds ON / 0.5–45 minutes OFF for matching the drain interval to system conditions
- Direct-Acting Solenoid Valve: 2/2-way valve design controls condensate discharge without a separate pilot circuit
- Serviceable Construction: Brass valve housing supports maintenance and long-term industrial use
- Visual Status: LED indicators show timer operation and cycle status
- Built-In TEST Function: Provides a convenient way to verify drain operation during setup or maintenance
- Environmental Protection: NEMA 4 / IP65 enclosure rating for industrial environments
- High-quality PCB components
- Designed to resist air locking during operation
- Suitable for compressed-air systems of any type and size
- Easy-grip timer adjustment knobs
Specifications
|
Part Number
|
2662
|
|
Brand
|
JORC
|
|
Product Line
|
OPTIMUM
|
|
Control Voltage
|
24V AC
|
|
Inlet and Outlet
|
3/8" NPT
|
|
Pressure Range
|
0–230 PSI (0–16 bar)
|
|
Dimensions
|
4.469 in. L × 1.969 in. W × 3.518 in. D
|
|
Maximum Compressor Capacity
|
Any size
|
|
Ambient Temperature
|
34°F to 131°F (1°C to 55°C)
|
|
Timer Cycle Range (ON/OFF)
|
0.5–10 seconds ON / 0.5–45 minutes OFF
|
|
Timer PCB
|
SMD technology
|
|
Timer Cycle Indication
|
LEDs
|
|
Valve Type
|
2/2-way, direct-acting
|
|
Valve Opening
|
4.5 mm (0.177 in.)
|
|
Valve Seals
|
FPM
|
|
Inlet Connection Height
|
10 mm (0.4 in.)
|
|
Timer Housing Material
|
ABS plastic
|
|
Valve Housing Material
|
Brass
|
|
Power Connection
|
DIN 43650 Form A
|
|
Environmental Protection
|
NEMA 4 / IP65
|
📦 Product Package and Manual
• (1) JORC 2662 OPTIMUM timer-controlled condensate drain
🔧 Installation and Setup Notes
Confirm electrical compatibility: Use the specified 24V AC supply and the listed DIN 43650 Form A connection.
Check system pressure: Keep operating pressure within 0–230 PSI (0–16 bar).
Set the timer: Adjust the ON and OFF cycles for the condensate load, then use the built-in TEST function to verify operation.
Follow the installation manual for wiring, connection, and maintenance instructions.
🏭 Common Applications
Use the JORC 2662 to provide timed condensate discharge for air compressors, refrigerated air dryers, and compressed-air systems with high condensate flow. Its adjustable cycle settings help match drain operation to changing condensate volume without relying on a fixed manual draining schedule.
|
|
 |
 |
 |
 |


|