Home > Condensate Drain Valves > Timer Controlled Condensate Drain Valves > OPTIMUM Series Timer Controlled Drains >

Jorc 2951 115V AC OPTIMUM Timer Controlled Drain, 1/4" NPT, 0-5000 PSI


Jorc 2951 115V AC 5000 PSI OPTIMUM Timer Controlled Drain
Jorc 2951 115V AC OPTIMUM Timer Controlled Drain, 1/4" NPT, 0-5000 PSI
 
Alternative Views:


Price: $467.04
Note: Delivery: 2-5 Business Days
MFG P/N: 2951
MFG: Jorc
Weight (lbs): 3

Quantity in Stock :3


Availability:
In Stock
Product Code: 2951
Qty:

Description
 

JORC 2951 OPTIMUM Timer-Controlled Condensate Drain, 115V AC

Adjustable timer operation provides scheduled condensate drainage for compressed air systems rated up to 5000 PSI. This 115V AC model includes a 6 ft power cord with plug.

✅ Refrigerated Dryers and Liquid Separators

Use this timer drain on high-pressure compressed air equipment within its 0–5000 PSI (0–345 bar) operating range. Separate timer adjustments control the discharge duration and the interval between cycles.

Scheduled Condensate Drainage for High-Pressure Equipment

For compressed air drainage applications rated up to 5000 PSI, the JORC 2951 OPTIMUM combines a 115V AC timer with a serviceable stainless steel solenoid valve. It is suitable for refrigerated dryers and liquid separators, including high-pressure applications with high flow rates.

The timer opens the valve at adjustable intervals, allowing the discharge duration and pause between cycles to be set separately. The 304 stainless steel housing contains a direct-acting valve with FPM seals. A TEST function allows an operational check, LED indicators display the cycle status, and a 6 ft power cord with plug is included.

Adjustable Drain Cycles

Set the valve on-time and off-time separately to match the drainage schedule.

LED Cycle Status

On/off indicators show the timer operating status.

Serviceable Valve

The solenoid valve can be serviced for maintenance.

TEST Function

Check valve operation using the built-in TEST feature.

Key Features & Benefits

  • Repeatable drainage: The adjustable timer provides precise drainage cycles.
  • No air locking: The drain operates without air locking during use.
  • Compressed air compatibility: Suitable for compressed air drainage applications within the listed pressure and temperature ratings.
  • Maintenance access: A serviceable valve allows maintenance of the valve assembly.

Specifications

Part Number 2951
Brand JORC
Product Series OPTIMUM
Drain Control Adjustable timer
Supply Voltage 115V AC
Operating Pressure 0–5000 PSI (0–345 bar)
Inlet Connection 1/4 in. NPT
Outlet Connection 1/4 in. NPT
Dimensions 4.424" Length x 1.969" Width x 3.911" Depth
Maximum Compressor Capacity Any Size
Ambient Temperature 34°F to 131°F (1°C to 55°C)
Timer On-Time / Off-Time 0.5–10 seconds / 0.5–45 minutes
Timer Circuit Board SMD technology
Timer Status Indication LEDs
Valve Type 2/2-way, direct-acting
Valve Opening 4.5 mm (0.177")
Valve Seals FPM
Inlet Connection Height 10 mm (0.4")
Valve Housing Material 304 Stainless Steel
Power Connection DIN 43650 Form A
Environmental Protection NEMA 4 (IP65)
Included Power Cord 6 ft power cord with plug

📄 Installation Manual

JORC OPTIMUM Condensate Drain Installation Manual

⚙️ Application Selection

Match the 115V AC supply, 0–5000 PSI (0–345 bar) pressure range, and 1/4-inch NPT connections to the installation. Set both timer adjustments for the application and use the installation manual for setup instructions.

🔧 Connections and Maintenance

The 2/2-way, direct-acting valve is serviceable. The DIN 43650 Form A power connection and included power cord support electrical connection; refer to the installation manual for wiring and maintenance instructions.

⏱️ Timer Operation

The timer on-time is adjustable from 0.5 to 10 seconds, and the off-time is adjustable from 0.5 to 45 minutes. LEDs show the on/off cycle status, and the TEST feature provides an operational check.


Related Products
Jorc 9010 Wall Mounting Bracket for OPTIMUM & EAD Series
Price: $27.84

Add
Jorc 9010 Wall Mounting Bracket