Jorc 2613 230V AC OPTIMUM Timer Controlled Drain, 1/2" NPT, 0-230 PSI, Steel Valve


Jorc 2613 230V AC OPTIMUM Timer Controlled Drain
Jorc 2613 230V AC OPTIMUM Timer Controlled Drain, 1/2" NPT, 0-230 PSI, Steel Valve
 
Alternative Views:


Price: $321.60
MFG P/N: 2613
MFG: Jorc
Weight (lbs): 3



Availability:
In Stock
Product Code: 2613
Qty:

Description
 

Jorc 2613 OPTIMUM Timer Controlled Condensate Drain Valve, 230V AC, 1/2" NPT, 304 Stainless Steel

OPTIMUM timer drain for compressed air condensate removal with 230V AC, 1/2" NPT inlet/outlet connections, 0-230 PSI (0-16 bar) pressure rating, adjustable cycle timing, LED status indication, and a 304 stainless steel valve housing.

Why Choose the Jorc 2613 OPTIMUM Timer Drain?

The Jorc 2613 OPTIMUM timer controlled condensate drain valve is designed to remove condensate from compressed air equipment without constant manual draining. This model uses a 304 stainless steel valve housing, a direct acting solenoid valve, LED cycle indication, adjustable timing, and a 4.5 mm (0.177") valve opening.

Use it on air compressors, refrigerated air dryers, filters, and other compressed air systems where reliable condensate discharge is needed under high-flow or steady-load operating conditions. The drain is rated for 0-230 PSI (0-16 bar) and includes 7 ft power cord for installation.

⚡ 230V AC

Runs on the listed AC supply voltage for compressed air drain control

🔩 1/2" NPT

Uses threaded inlet and outlet connections for condensate drain plumbing

💧 0-230 PSI

Built for compressed air systems up to the listed operating pressure

🛠️ 304 Stainless Steel

Durable valve body with serviceable design for maintenance access

⚠️ Confirm Voltage, Port Size, and Pressure Rating

Before ordering, confirm the drain voltage, 1/2" NPT inlet/outlet size, available power connection, condensate line routing, and system pressure. This model is for compressed air condensate draining and should be installed according to the Jorc OPTIMUM Timer Drain installation manual.

This model is rated for 0-230 PSI (0-16 bar). Do not use it outside the specified compressed air system limits.

📋 Timer Drain Operation

The Jorc 2613 uses adjustable ON/OFF cycle timing to discharge condensate automatically. The timer cycle range is 0.5-10 sec / 0.5-45 min, with LED indication for operating status and a TEST function for quick manual checks. The valve is a 2/2 way, direct acting design with FPM seals.

Typical use: Automatic condensate removal from compressed air systems, dryers, filters, and compressor drain points where repeatable timed discharge is preferred.

Key Features & Benefits

  • 230V AC
  • 1/2" NPT inlet & outlet
  • Rated for 0-230 PSI (0-16 bar)
  • Serviceable valve
  • Does not air lock while in use
  • Made for any type & any size compressed air system
  • TEST feature
  • Accurate time cycles
  • LEDs indicate timer cycle status
  • Environmental protection: NEMA 4 (IP 65 - total protection from dust & water jets in any direction)

Technical Specifications

Brand Jorc
Model Number 2613
Series OPTIMUM
Product Type Timer Controlled Condensate Drain Valve
Voltage 230V AC
Inlet / Outlet Connection 1/2" NPT
Pressure Rating 0-230 PSI (0-16 bar)
Valve Housing Material 304 Stainless Steel
Timer Housing Material ABS Plastic
Valve Type 2/2 Way, Direct Acting
Valve Opening 4.5 mm (0.177")
Valve Seals FPM
Timer Cycle Range 0.5-10 sec / 0.5-45 min
Timer PCB SMD Technology
Timer Cycle Indication LEDs
Max Compressor Capacity Any Size
Ambient Temperature 34 F to 131 F (1 C to 55 C)
Inlet Connection Height 10 mm (0.4")
Power Connection DIN 43650 Form A (included)
Environmental Protection NEMA 4 (IP 65 - total protection from dust & water jets in any direction)
Dimensions 4.469" Length x 1.969" Width x 3.518" Depth
Power Cord 7 ft power cord

📋 Basic Installation Overview

1. Confirm Utilities: Verify 230V AC power, the correct 1/2" NPT inlet and outlet connection size, and a suitable condensate discharge location.

2. Install in the Drain Line: Mount the drain in the correct orientation and avoid piping stress, blocked outlets, or sharp hose bends.

3. Set the Timer: Adjust the ON/OFF cycle for the amount of condensate produced by the compressor, dryer, or filter location.

4. Test the Valve: Use the TEST function to confirm discharge before placing the system back into normal operation.

Always follow the Jorc OPTIMUM Timer Drain installation manual before operation.

📦 What's Included

• Timer controlled condensate drain valve
• 7 ft power cord
• DIN 43650 Form A (included) power connection
• Jorc OPTIMUM Timer Drain installation manual reference

📞 Jorc Product Support

Reference the Jorc OPTIMUM Timer Drain Installation Manual
Use the manual to confirm wiring, timer adjustment, valve installation, service steps, and compressed air system requirements for this model.

This OPTIMUM timer drain is intended for automatic condensate removal in compressed air applications.


Related Products
Jorc 9010 Wall Mounting Bracket for OPTIMUM & EAD Series
Price: $26.88

Add
Jorc 9010 Wall Mounting Bracket



Macromatic THR-11368-31J Encapsulated Time Delay Relay, Watchdog, 24V, 1-100 Sec, Internal Jumper $28.31