Description
 

The Macromatic CUH05A1AC is a current sensing relay. This encapsulated relay has an input voltage of 240V AC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 0.5-5A and a trip time delay of 0.15-7 seconds. There is no sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 0.5-5 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- None
  • Input Voltage- 240V AC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH05A1AC has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

Under Current Sensing Relay with Encapsulated Housing CUH05A1AC




Saginaw SCE-16PBA Sloped Front Push Button Enclosure, 16 Position, 30.5mm $253.14
Deca CDU4M Screw Clamp Mini DIN Rail Terminal Block, 2 Poles, 10-22 AWG $0.60
Saginaw SCE-606CHNFSS Stainless Steel Continuous Hinge Enclosure, 6.13" x 6" x 4" $270.35
Red Lion PAXDP010 Panel Meter, Dual Process Input Meter, 5 Digit, Red LED, DC $737.04
Hoffman BFVL13R2 Vinyl Insulated Ring Terminal 1/2" Stud 16-14 AWG $0.16
ILME CAP-16LS229 C-Type Surface Mount Housing, Size 77.27, Lever & Cover, PG 29, 2 Entries $61.66
GardTec SC92-W2 92mm Wire Form Fan Guard $0.60
Hoffman SPEEDE2CL 2 Position Clear Red Wire Connector - Fast Twist-On Electrical Terminal for Industrial Wiring $0.10
Macromatic ARP024A2R DPDT 24V Duplexor Alternating Relay $49.59