Home > Relays > Liquid Level Control Relays >

Macromatic LCP2A100F2 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 2 Sec Delay


Macromatic 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 2 Sec
Macromatic LCP2A100F2 120V Single Probe Liquid Level Relay, Pump Up, 4.7K to 100K, 2 Sec Delay
 
Alternative Views:


Price: $90.38
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: LCP2A100F2
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: LCP2A100F2
Qty:

Description
 

The Macromatic LCP2A100F2 is a single probe pump up (fill) liquid level control relay. This 8 Pin plug-in relay has an input voltage of 120V AC. It monitors the level of conductive liquid (such as tap water, chemical solution, seawater, etc.) in a tank. Sensitivity is adjustable within the set range. Used to monitor liquid levels in the tank for pumps, solenoids, or valves. Electroplating is prevented due to the DC voltage pulsed through the probe, while the fixed time delay prevents rapid cycling. Pilot duty rating. Note: LCP2B250F2 pictured for reference.

Specifications

  • Relay Function- Single Probe Pump Up Liquid Level Control Relay
  • Input Voltage- 120V AC
  • Output- 10A SPDT
  • Sensitivity Range- 4.7K to 100K Ohms
  • Voltage Tolerance- AC Operation: +10 / -15% of nominal at 50/60 Hz
  • Load- 2 VA
  • Probe Voltage- 5V DC Pulsed
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10A @ 240V AC / 7A @ 28V DC, 1/4HP @ 120V AC (N.O.)
  • Life- Mechanical: 10,000,000 operations, Full Load: 100,000 operations
  • Response Time- Pick Up: 2 Seconds, Drop Out: 500 Milliseconds
  • Dimensions- 2.4" Height x 1.7" Width x 3.2" Depth
  • Approvals- UL and CUL recognized, UL & CUL listed (with Socket)

When the level of conductive liquid goes below the probe, the fixed time delay starts and the LED flashes red. The relay energizes after the time delay and the LED is solid red. It stays this way until the liquid comes back up to the probe. The relay is then no longer energized and the LED is green.

Liquid Level Relay Connection Diagram

Macromatic LCP Series Installation Instructions

Macromatic Single Probe Pump Up Liquid Level Control Relay with 2 Second Delay LCP2A100F2


Related Products
Macromatic 70169-D 8 Pin Octal Socket
Price: $5.04

Add
Macromatic 70169-D 8 Pin Octal Socket



Jorc 4083 24V DC TEC-44 Timer Controlled Drain, 1/2" NPT, 0-600 PSI $673.75
Macromatic PTA2002M Percentage Timer, 2 Min, 120V AC $164.20
Sealcon CD16DA-FE M16 Dome .20" - .39" (5 - 10 mm) EMI/RFI Proof Elongated Cord Grip, Feed Through $26.91
Hoffman B8 Non-Insulated Ring Terminal 5/16" Stud 16-14 AWG $0.13
Macromatic SFP024C100 Dual Channel 24V, 4.7K to 100K Pump Seal Failure Relay $78.29
Macromatic SFF024C100 Seal Leak Relay, Dual Channel 24V 4.7K to 100K $97.04
Meltric DS2MC DS200 Padlockable Inlet Cap $812.59
Sealcon CD21AS-03 Black PG 21 Dome .28" x .55" (7 x 14 mm) Romex Cord Grip $4.47
Kacon KMSR-AS1004 Single Phase Solid State Relay, 90-265V AC Input, 90-480V AC Load, 100A $93.39