Home > Relays > Current Sensing Relays >

Macromatic CUH50A2AC Under Current Sensing Relay, 5-50A, 0.15-7 Sec, 120V


Macromatic CUH50A2AC Under Current Sensing Relay
Macromatic CUH50A2AC Under Current Sensing Relay, 5-50A, 0.15-7 Sec, 120V
 
Alternative Views:


Price: $87.79
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: CUH50A2AC
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CUH50A2AC
Qty:

Description
 

The Macromatic CUH50A2AC is a current sensing relay. This encapsulated relay has an input voltage of 120V AC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 5-50A and a trip time delay of 0.15-7 seconds. There is no sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 5-50 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- None
  • Input Voltage- 120V AC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-50A Turns; 300A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH50A2AC has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

120V AC Encapsulated Under Current Sensing Relay CUH50A2AC




Kacon KLSAL2 Medium Duty Limit Switch, Snap Action Roller Lever, 1NO 1NC Contacts $24.45
Light Efficient Design LED-8061E22 28W LED Filament Light, 2200K, 120/277V $23.40
Mencom MIN-5FP-3-R MIN Size I Cordset, 5 Pole, Female Right Angle, 8A, 3 Feet $49.27
Menics ATEPR-10-RYGBC 56 mm 5 Stack Andon Tower Light w/ Push Button Control Box, 110V, 10Ft Cable $327.18
Mencom MACB-6FP-2M-R 1/2-20 Cordset, 6 Pole, Female Right Angle, 2 M, Shielded $50.26
Mencom MDCM-8MR-PCB-R M12 8-Pole Male Right Angle Receptacle, Shielded, 2A $22.94
Deca WS35 Warning Cover for CDU35 DIN Rail Terminal Block $0.43
Light Efficient Design LED-8062M22 32W LED Filament Light, 2200K, 120/277V $35.10
Menics MT8B1DL-R 1 Stack 85mm Tower Light, Red, 12V $48.65