Macromatic CUH50A2AE Under Current Sensing Relay, 5-50A, 0.15-7 Sec, 120V, 2 Sec Delay


Macromatic CUH50A2AE Under Current Sensing Relay
Macromatic CUH50A2AE Under Current Sensing Relay, 5-50A, 0.15-7 Sec, 120V, 2 Sec Delay
 
Alternative Views:


Price: $87.79
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: CUH50A2AE
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: CUH50A2AE
Qty:

Description
 

The Macromatic CUH50A2AE is a current sensing relay. This encapsulated relay has an input voltage of 120V AC. It is designed to monitor for under current faults and has an output of 10A SPDT. It checks AC current, with an adjustable range of 5-50A and a trip time delay of 0.15-7 seconds. There is a 2 second sensing time delay on startup. The built-in current transformer promotes easy access and greater sensitivity. The encapsulated casing is ideal for harsh environments. Note: Image is an approximation. Actual part may differ.

Specifications

  • Relay Function- Under Current
  • Current Monitor Range- 5-50 Amps
  • Time Trip Delay- 0.15-7 seconds
  • Sensing Time Delay on Startup- 2 Seconds
  • Input Voltage- 120V AC
  • Output- 10A SPDT
  • Input Voltage Tolerance- +10/-15% of nominal
  • Load- 2VA
  • Current Sensing- Type: Toroidal, through hole wiring
    Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
    Maximum Allowable Current: Steady-50A Turns; 300A Inrush for 10 Seconds
    Trip Point Hysteresis: +5%
  • Response Time- Time Delay on Reset (Relay OFF): 100ms
    Reset Time: 400ms
  • Operating Temperature- -28 C to 65 C (-18 F to 149 F)
  • Storage Temperature- -40 C to 85 C (-40 F to 185 F)
  • Output Contacts- 10 Amperes @ 240VAC, General Purpose; 8 Amperes @ 28VDC, Resistive; 1/4HP @ 120/240VAC; B300
  • Life- Mechanical: 10,000,000 Operations, Full Load: 100,000 Operations
  • Mounting- Surface mount with two #6 screws
  • Termination- 0.25" male quick-connect terminals
  • Overall Dimensions- 3.5" Height x 2.5" Width x 1.5" Depth
  • Approvals- UL & CUL Recognized

When the input voltage is introduced, and after the 2 second start-up delay, the relay then starts monitoring for faults. For an undercurrent situation, the current needs to go under the set Fault Trip Current for longer than the time delay. The relay energizes after the time delay and will de-energize once the current goes over the reset level. The CUH50A2AE has an LED indicator which glows red to show if an undercurrent fault is detected. Has pilot duty rating. Applications such as process control, monitoring for locked rotor or load loss, and open heater or lamp are all suited for this type of relay.

Macromatic CUH Series Relay Installation Manual

CUH50A2AE Under Current Sensing Electrical Relay with 2 Second Startup Delay




Z+F V70FS007002 Red PVC Insulated Quick Disconnect Terminal, 20-16 AWG, 2.8 x 0.8 mm, Male $0.12
Sealcon PFC12 Conduit Clip Mounting Bracket, Fits Size 12 $1.80
Mencom 207MPOT PG 7 Lock Nut, Nickel Plated Brass, w/ Cutting Edge $3.94
Menics ATES-RG 56 mm 2 Stack Andon Tower Light w/ Selector Switch Control Box, Red Green, 110V $169.40
Mencom MDC-2MP-10M M12 Cordset, 2 Pole, Male Straight, 10 M $34.54
Macromatic ISEUR1 1 Channel Intrinsically Safe Relay, 102-132VAC / 10-125VDC, Standard Logic $112.93
Boxco BC-1018ST Steel Back Panel, for 100 x 185mm Enclosure $2.85
Jorc 2302 230V AC EAD Timer Controlled Drain, 3/8" NPT, 0-230 PSI $111.76